用于重症监护病房患者监测的可穿戴设备。

IF 2.8 Q2 CRITICAL CARE MEDICINE
Alessandra Angelucci, Massimiliano Greco, Maurizio Cecconi, Andrea Aliverti
{"title":"用于重症监护病房患者监测的可穿戴设备。","authors":"Alessandra Angelucci, Massimiliano Greco, Maurizio Cecconi, Andrea Aliverti","doi":"10.1186/s40635-025-00738-8","DOIUrl":null,"url":null,"abstract":"<p><p>Wearable devices (WDs), originally launched for fitness, are now increasingly recognized as valuable technologies in several clinical applications, including the intensive care unit (ICU). These devices allow for continuous, non-invasive monitoring of physiological parameters such as heart rate, respiratory rate, blood pressure, glucose levels, and posture and movement. WDs offer significant advantages in making monitoring less invasive and could help bridge gaps between ICUs and standard hospital wards, ensuring more effective transitioning to lower-level monitoring after discharge from the ICU. WDs are also promising tools in applications like delirium detection, vital signs monitoring in limited resource settings, and prevention of hospital-acquired pressure injuries. Despite the potential of WDs, challenges such as measurement accuracy, explainability of data processing algorithms, and actual integration into the clinical decision-making process persist. Further research is necessary to validate the effectiveness of WDs and to integrate them into clinical practice in critical care environments.Take home messages Wearable devices are revolutionizing patient monitoring in ICUs and step down units by providing continuous, non-invasive, and cost-effective solutions. Validation of their accuracy and integration in the clinical decision-making process remain crucial for widespread clinical adoption.</p>","PeriodicalId":13750,"journal":{"name":"Intensive Care Medicine Experimental","volume":"13 1","pages":"26"},"PeriodicalIF":2.8000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11868008/pdf/","citationCount":"0","resultStr":"{\"title\":\"Wearable devices for patient monitoring in the intensive care unit.\",\"authors\":\"Alessandra Angelucci, Massimiliano Greco, Maurizio Cecconi, Andrea Aliverti\",\"doi\":\"10.1186/s40635-025-00738-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Wearable devices (WDs), originally launched for fitness, are now increasingly recognized as valuable technologies in several clinical applications, including the intensive care unit (ICU). These devices allow for continuous, non-invasive monitoring of physiological parameters such as heart rate, respiratory rate, blood pressure, glucose levels, and posture and movement. WDs offer significant advantages in making monitoring less invasive and could help bridge gaps between ICUs and standard hospital wards, ensuring more effective transitioning to lower-level monitoring after discharge from the ICU. WDs are also promising tools in applications like delirium detection, vital signs monitoring in limited resource settings, and prevention of hospital-acquired pressure injuries. Despite the potential of WDs, challenges such as measurement accuracy, explainability of data processing algorithms, and actual integration into the clinical decision-making process persist. Further research is necessary to validate the effectiveness of WDs and to integrate them into clinical practice in critical care environments.Take home messages Wearable devices are revolutionizing patient monitoring in ICUs and step down units by providing continuous, non-invasive, and cost-effective solutions. Validation of their accuracy and integration in the clinical decision-making process remain crucial for widespread clinical adoption.</p>\",\"PeriodicalId\":13750,\"journal\":{\"name\":\"Intensive Care Medicine Experimental\",\"volume\":\"13 1\",\"pages\":\"26\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2025-02-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11868008/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Intensive Care Medicine Experimental\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s40635-025-00738-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Intensive Care Medicine Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40635-025-00738-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

可穿戴设备(wd)最初是为健身而推出的,现在越来越被认为是一些临床应用中的有价值的技术,包括重症监护病房(ICU)。这些设备允许对心率、呼吸频率、血压、血糖水平、姿势和运动等生理参数进行连续、无创监测。WDs在减少监测侵入性方面具有显著优势,可以帮助弥合ICU和标准医院病房之间的差距,确保从ICU出院后更有效地过渡到较低水平的监测。WDs在谵妄检测、有限资源环境下的生命体征监测和预防医院获得性压力伤害等应用中也是很有前途的工具。尽管WDs具有潜力,但诸如测量准确性、数据处理算法的可解释性以及与临床决策过程的实际整合等挑战仍然存在。需要进一步的研究来验证WDs的有效性,并将其纳入重症监护环境的临床实践。可穿戴设备通过提供连续、非侵入性和经济高效的解决方案,正在彻底改变重症监护病房的患者监护。在临床决策过程中验证其准确性和整合对于广泛的临床采用仍然至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Wearable devices for patient monitoring in the intensive care unit.

Wearable devices for patient monitoring in the intensive care unit.

Wearable devices (WDs), originally launched for fitness, are now increasingly recognized as valuable technologies in several clinical applications, including the intensive care unit (ICU). These devices allow for continuous, non-invasive monitoring of physiological parameters such as heart rate, respiratory rate, blood pressure, glucose levels, and posture and movement. WDs offer significant advantages in making monitoring less invasive and could help bridge gaps between ICUs and standard hospital wards, ensuring more effective transitioning to lower-level monitoring after discharge from the ICU. WDs are also promising tools in applications like delirium detection, vital signs monitoring in limited resource settings, and prevention of hospital-acquired pressure injuries. Despite the potential of WDs, challenges such as measurement accuracy, explainability of data processing algorithms, and actual integration into the clinical decision-making process persist. Further research is necessary to validate the effectiveness of WDs and to integrate them into clinical practice in critical care environments.Take home messages Wearable devices are revolutionizing patient monitoring in ICUs and step down units by providing continuous, non-invasive, and cost-effective solutions. Validation of their accuracy and integration in the clinical decision-making process remain crucial for widespread clinical adoption.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Intensive Care Medicine Experimental
Intensive Care Medicine Experimental CRITICAL CARE MEDICINE-
CiteScore
5.10
自引率
2.90%
发文量
48
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信