不同根管旋转锉预备根管后牙本质裂缝的显微计算机断层评估:一项离体研究。

IF 2.7 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Mohammed Mana Alzamanan, Abdullah Abdulrahman Albassam, Emad Mahmoud Khattab, Faisal Turki Alghamdi
{"title":"不同根管旋转锉预备根管后牙本质裂缝的显微计算机断层评估:一项离体研究。","authors":"Mohammed Mana Alzamanan, Abdullah Abdulrahman Albassam, Emad Mahmoud Khattab, Faisal Turki Alghamdi","doi":"10.17219/dmp/149733","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The occurrence of dentinal cracks is rather frequent during root canal preparation and increases with some endodontic file systems. There have been few ex vivo studies on the incidence of the formation of microcracks after root canal preparation, using the micro-computed tomography (micro-CT) analysis.</p><p><strong>Objectives: </strong>The aim of the present study was to compare the incidence of dentinal cracks after using the XP-endo® Shaper, TRUShape®, ProTaper Next™ (PTN), and ProTaper Universal™ (PTU) instruments in the preparation of mandibular premolar teeth with oval canals, using the micro-CT evaluation method.</p><p><strong>Material and methods: </strong>Thirty-six extracted human mandibular premolars with single oval root canals were distributed randomly to 4 experimental groups (n = 9) for root canal preparation: group 1 - XP-endo Shaper; group 2 - TRUShape; group 3 - PTN; and group 4 - PTU. The teeth were scanned using micro-CT with high resolution, before and after mechanical root preparation. Then, the cross-sectional images of preand post-scanning were visualized simultaneously to detect new dentinal cracks. The number of dentinal cracks was determined as percentage for each group, and the results were statistically analyzed using the Wilcoxon signed rank test and the Kruskal-Wallis test.</p><p><strong>Results: </strong>A total of 49,628 cross-sectional images were obtained from preand post-scanning with micro-CT. Dentinal cracks were observed in 11,223 (22.6%) of the images. No new dentinal cracks were formed after using XP-endo Shaper, TRUShape or PTN. New dentinal cracks were found in the PTU group, and the difference between the percentages of the preand post-preparation dentinal cracks was statistically significant (37.6% vs. 62.4%) (p = 0.008).</p><p><strong>Conclusions: </strong>The use of the heat-treated nickel-titanium (NiTi) files (XP-endo Shaper, TRUShape, PTN) did not lead to the formation of new dentinal cracks. New dentinal cracks were formed while using the traditional NiTi file (PTU) only. Future studies are required to investigate the association between the formation of dentinal cracks and new endodontic file systems.</p>","PeriodicalId":11191,"journal":{"name":"Dental and Medical Problems","volume":"62 1","pages":"89-98"},"PeriodicalIF":2.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Micro-computed tomography evaluation of dentinal cracks after root canal preparation with different endodontic rotary files: An ex vivo study.\",\"authors\":\"Mohammed Mana Alzamanan, Abdullah Abdulrahman Albassam, Emad Mahmoud Khattab, Faisal Turki Alghamdi\",\"doi\":\"10.17219/dmp/149733\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The occurrence of dentinal cracks is rather frequent during root canal preparation and increases with some endodontic file systems. There have been few ex vivo studies on the incidence of the formation of microcracks after root canal preparation, using the micro-computed tomography (micro-CT) analysis.</p><p><strong>Objectives: </strong>The aim of the present study was to compare the incidence of dentinal cracks after using the XP-endo® Shaper, TRUShape®, ProTaper Next™ (PTN), and ProTaper Universal™ (PTU) instruments in the preparation of mandibular premolar teeth with oval canals, using the micro-CT evaluation method.</p><p><strong>Material and methods: </strong>Thirty-six extracted human mandibular premolars with single oval root canals were distributed randomly to 4 experimental groups (n = 9) for root canal preparation: group 1 - XP-endo Shaper; group 2 - TRUShape; group 3 - PTN; and group 4 - PTU. The teeth were scanned using micro-CT with high resolution, before and after mechanical root preparation. Then, the cross-sectional images of preand post-scanning were visualized simultaneously to detect new dentinal cracks. The number of dentinal cracks was determined as percentage for each group, and the results were statistically analyzed using the Wilcoxon signed rank test and the Kruskal-Wallis test.</p><p><strong>Results: </strong>A total of 49,628 cross-sectional images were obtained from preand post-scanning with micro-CT. Dentinal cracks were observed in 11,223 (22.6%) of the images. No new dentinal cracks were formed after using XP-endo Shaper, TRUShape or PTN. New dentinal cracks were found in the PTU group, and the difference between the percentages of the preand post-preparation dentinal cracks was statistically significant (37.6% vs. 62.4%) (p = 0.008).</p><p><strong>Conclusions: </strong>The use of the heat-treated nickel-titanium (NiTi) files (XP-endo Shaper, TRUShape, PTN) did not lead to the formation of new dentinal cracks. New dentinal cracks were formed while using the traditional NiTi file (PTU) only. Future studies are required to investigate the association between the formation of dentinal cracks and new endodontic file systems.</p>\",\"PeriodicalId\":11191,\"journal\":{\"name\":\"Dental and Medical Problems\",\"volume\":\"62 1\",\"pages\":\"89-98\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental and Medical Problems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17219/dmp/149733\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental and Medical Problems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17219/dmp/149733","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:在根管预备过程中,牙本质裂缝的发生率相当高,而且随着一些根管治疗锉系统的使用而增加。关于根管预备后微裂缝形成的发生率,很少有使用显微计算机断层扫描(micro-CT)分析的体外研究:本研究的目的是使用显微计算机断层扫描评估方法,比较在使用 XP-endo® Shaper、TRUShape®、ProTaper Next™ (PTN) 和 ProTaper Universal™ (PTU) 器械制备具有椭圆形根管的下颌前磨牙后牙本质裂纹的发生率:将拔出的 36 颗具有单椭圆形根管的人类下颌前磨牙随机分配到 4 个实验组(n = 9)进行根管预备:第 1 组 - XP-endo Shaper;第 2 组 - TRUShape;第 3 组 - PTN;第 4 组 - PTU。在机械根管预备前后,使用高分辨率显微 CT 扫描牙齿。然后,同时观察扫描前后的横截面图像,以检测新的牙本质裂缝。每组牙本质裂纹的数量以百分比表示,结果采用 Wilcoxon 符号秩检验和 Kruskal-Wallis 检验进行统计分析:使用 micro-CT 扫描前后共获得 49 628 张横截面图像。在 11 223 张图像(22.6%)中观察到牙本质裂纹。使用 XP-endo Shaper、TRUShape 或 PTN 后,没有发现新的牙本质裂缝。在 PTU 组中发现了新的牙本质裂纹,而制备前和制备后牙本质裂纹的百分比差异具有统计学意义(37.6% 对 62.4%)(p = 0.008):结论:使用热处理过的镍钛(NiTi)锉(XP-endo Shaper、TRUShape、PTN)不会导致新牙本质裂纹的形成。只有在使用传统的镍钛锉 (PTU) 时才会形成新的牙本质裂纹。未来的研究需要调查牙本质裂缝的形成与新的牙髓治疗锉系统之间的关联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Micro-computed tomography evaluation of dentinal cracks after root canal preparation with different endodontic rotary files: An ex vivo study.

Background: The occurrence of dentinal cracks is rather frequent during root canal preparation and increases with some endodontic file systems. There have been few ex vivo studies on the incidence of the formation of microcracks after root canal preparation, using the micro-computed tomography (micro-CT) analysis.

Objectives: The aim of the present study was to compare the incidence of dentinal cracks after using the XP-endo® Shaper, TRUShape®, ProTaper Next™ (PTN), and ProTaper Universal™ (PTU) instruments in the preparation of mandibular premolar teeth with oval canals, using the micro-CT evaluation method.

Material and methods: Thirty-six extracted human mandibular premolars with single oval root canals were distributed randomly to 4 experimental groups (n = 9) for root canal preparation: group 1 - XP-endo Shaper; group 2 - TRUShape; group 3 - PTN; and group 4 - PTU. The teeth were scanned using micro-CT with high resolution, before and after mechanical root preparation. Then, the cross-sectional images of preand post-scanning were visualized simultaneously to detect new dentinal cracks. The number of dentinal cracks was determined as percentage for each group, and the results were statistically analyzed using the Wilcoxon signed rank test and the Kruskal-Wallis test.

Results: A total of 49,628 cross-sectional images were obtained from preand post-scanning with micro-CT. Dentinal cracks were observed in 11,223 (22.6%) of the images. No new dentinal cracks were formed after using XP-endo Shaper, TRUShape or PTN. New dentinal cracks were found in the PTU group, and the difference between the percentages of the preand post-preparation dentinal cracks was statistically significant (37.6% vs. 62.4%) (p = 0.008).

Conclusions: The use of the heat-treated nickel-titanium (NiTi) files (XP-endo Shaper, TRUShape, PTN) did not lead to the formation of new dentinal cracks. New dentinal cracks were formed while using the traditional NiTi file (PTU) only. Future studies are required to investigate the association between the formation of dentinal cracks and new endodontic file systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.00
自引率
3.80%
发文量
58
审稿时长
53 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信