简单方便的三电极布局在化学刺激下实时电旋转测量。

IF 3 3区 生物学 Q2 BIOCHEMICAL RESEARCH METHODS
ELECTROPHORESIS Pub Date : 2025-02-26 DOI:10.1002/elps.8121
Masato Suzuki, Ryoga Yamada, Yuki Imou, Yushi Isozaki, Tomoyuki Yasukawa
{"title":"简单方便的三电极布局在化学刺激下实时电旋转测量。","authors":"Masato Suzuki, Ryoga Yamada, Yuki Imou, Yushi Isozaki, Tomoyuki Yasukawa","doi":"10.1002/elps.8121","DOIUrl":null,"url":null,"abstract":"<p><p>We developed a novel electrorotation (ROT) device featuring a microwell array with three electrodes. This device allows to monitor the increase in membrane capacitance of cells subjected to chemical stimulation. The microwell array is integrated into the bottom of a fluidic channel and holds rotating cells during stimulation with a solution containing a chemical agent. Positive dielectrophoresis (p-DEP) effectively traps cells in microwells, whereas negative DEP (n-DEP) facilitates the rapid formation of single-cell presence. Alternating current (AC) voltages with a 120° phase shift applied across the three electrodes enable vertical and simultaneous rotation of cells. We observed a peak in rotation rate as a function of applied frequency, with the frequency spectrum shifting to lower frequencies as membrane capacitance increased. A positive correlation was identified between rotation rate and membrane capacitance, so monitoring in the low-frequency range is advantageous. Although n-DEP at lower frequencies risks removing cells from microwells, the continuous monitoring of the ROT rate during chemical stimulation was achieved by regulating the height of the ROT center of cells. We demonstrated the monitoring of membrane capacitance increase induced by Ca<sup>2+</sup> influx from ionomycin. This simple configuration facilitates statistical analysis of ROT rates without fluorescent labeling, making it suitable for label-free assessments of white blood cells' responses to stimuli.</p>","PeriodicalId":11596,"journal":{"name":"ELECTROPHORESIS","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simple and Convenient Three-Electrode Layout for Real-Time Electrorotation Measurement Upon Chemical Stimulation.\",\"authors\":\"Masato Suzuki, Ryoga Yamada, Yuki Imou, Yushi Isozaki, Tomoyuki Yasukawa\",\"doi\":\"10.1002/elps.8121\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We developed a novel electrorotation (ROT) device featuring a microwell array with three electrodes. This device allows to monitor the increase in membrane capacitance of cells subjected to chemical stimulation. The microwell array is integrated into the bottom of a fluidic channel and holds rotating cells during stimulation with a solution containing a chemical agent. Positive dielectrophoresis (p-DEP) effectively traps cells in microwells, whereas negative DEP (n-DEP) facilitates the rapid formation of single-cell presence. Alternating current (AC) voltages with a 120° phase shift applied across the three electrodes enable vertical and simultaneous rotation of cells. We observed a peak in rotation rate as a function of applied frequency, with the frequency spectrum shifting to lower frequencies as membrane capacitance increased. A positive correlation was identified between rotation rate and membrane capacitance, so monitoring in the low-frequency range is advantageous. Although n-DEP at lower frequencies risks removing cells from microwells, the continuous monitoring of the ROT rate during chemical stimulation was achieved by regulating the height of the ROT center of cells. We demonstrated the monitoring of membrane capacitance increase induced by Ca<sup>2+</sup> influx from ionomycin. This simple configuration facilitates statistical analysis of ROT rates without fluorescent labeling, making it suitable for label-free assessments of white blood cells' responses to stimuli.</p>\",\"PeriodicalId\":11596,\"journal\":{\"name\":\"ELECTROPHORESIS\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-02-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ELECTROPHORESIS\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1002/elps.8121\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ELECTROPHORESIS","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1002/elps.8121","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

我们开发了一种具有三个电极的微孔阵列的新型电旋转(ROT)装置。这种装置可以监测受到化学刺激的细胞膜电容的增加。微孔阵列集成在流体通道的底部,并在含有化学剂的溶液刺激期间保持旋转细胞。正dielectrophoresis (p-DEP)有效地将细胞困在微孔中,而负dip (n-DEP)则促进单细胞的快速形成。在三个电极上施加120°相移的交流电流(AC)电压,使电池能够垂直和同时旋转。我们观察到旋转速率的峰值作为施加频率的函数,随着膜电容的增加,频谱向较低的频率移动。旋转速率与膜电容呈正相关,因此在低频范围内进行监测是有利的。尽管较低频率的n-DEP可能会将细胞从微孔中移除,但通过调节细胞ROT中心的高度,可以实现化学刺激期间对ROT率的连续监测。我们展示了由离子霉素引起的Ca2+内流诱导的膜电容增加的监测。这种简单的配置便于在没有荧光标记的情况下对ROT率进行统计分析,使其适合于对白细胞对刺激的反应进行无标记评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simple and Convenient Three-Electrode Layout for Real-Time Electrorotation Measurement Upon Chemical Stimulation.

We developed a novel electrorotation (ROT) device featuring a microwell array with three electrodes. This device allows to monitor the increase in membrane capacitance of cells subjected to chemical stimulation. The microwell array is integrated into the bottom of a fluidic channel and holds rotating cells during stimulation with a solution containing a chemical agent. Positive dielectrophoresis (p-DEP) effectively traps cells in microwells, whereas negative DEP (n-DEP) facilitates the rapid formation of single-cell presence. Alternating current (AC) voltages with a 120° phase shift applied across the three electrodes enable vertical and simultaneous rotation of cells. We observed a peak in rotation rate as a function of applied frequency, with the frequency spectrum shifting to lower frequencies as membrane capacitance increased. A positive correlation was identified between rotation rate and membrane capacitance, so monitoring in the low-frequency range is advantageous. Although n-DEP at lower frequencies risks removing cells from microwells, the continuous monitoring of the ROT rate during chemical stimulation was achieved by regulating the height of the ROT center of cells. We demonstrated the monitoring of membrane capacitance increase induced by Ca2+ influx from ionomycin. This simple configuration facilitates statistical analysis of ROT rates without fluorescent labeling, making it suitable for label-free assessments of white blood cells' responses to stimuli.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ELECTROPHORESIS
ELECTROPHORESIS 生物-分析化学
CiteScore
6.30
自引率
13.80%
发文量
244
审稿时长
1.9 months
期刊介绍: ELECTROPHORESIS is an international journal that publishes original manuscripts on all aspects of electrophoresis, and liquid phase separations (e.g., HPLC, micro- and nano-LC, UHPLC, micro- and nano-fluidics, liquid-phase micro-extractions, etc.). Topics include new or improved analytical and preparative methods, sample preparation, development of theory, and innovative applications of electrophoretic and liquid phase separations methods in the study of nucleic acids, proteins, carbohydrates natural products, pharmaceuticals, food analysis, environmental species and other compounds of importance to the life sciences. Papers in the areas of microfluidics and proteomics, which are not limited to electrophoresis-based methods, will also be accepted for publication. Contributions focused on hyphenated and omics techniques are also of interest. Proteomics is within the scope, if related to its fundamentals and new technical approaches. Proteomics applications are only considered in particular cases. Papers describing the application of standard electrophoretic methods will not be considered. Papers on nanoanalysis intended for publication in ELECTROPHORESIS should focus on one or more of the following topics: • Nanoscale electrokinetics and phenomena related to electric double layer and/or confinement in nano-sized geometry • Single cell and subcellular analysis • Nanosensors and ultrasensitive detection aspects (e.g., involving quantum dots, "nanoelectrodes" or nanospray MS) • Nanoscale/nanopore DNA sequencing (next generation sequencing) • Micro- and nanoscale sample preparation • Nanoparticles and cells analyses by dielectrophoresis • Separation-based analysis using nanoparticles, nanotubes and nanowires.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信