{"title":"BI-RADS 3超声表现的评价:恶性病变的频率、发生率和肿瘤大小。","authors":"Hanifa Fejzić, Svjetlana Mujagić, Belkisa Izić","doi":"10.5644/ama2006-124.467","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the research was to determine the frequency of BI-RADS category 3 findings in ultrasound examinations in relation to the total number of patients, the frequency of malignant lesions, and their average size at the time of detection in BI-RADS 3 ultrasound findings.</p><p><strong>Patients and methods: </strong>A cross-sectional study was performed on 335 patients (aged 40-75 years) classified in BI-RADS category 3, at the Tuzla Breast Center, University Clinical Center, in the period from March 2017 to November 2020. A total of 13,760 ultrasound examinations were performed, using a Toshiba Xario 100 ultrasound machine with a 12 MHz linear probe. Patients were divided into premenopausal and postmenopausal groups, excluding patients with symptoms and those with previous breast cancer surgery. The images were stored using the Institution's Pictures Activation and Communication System.</p><p><strong>Results: </strong>BI-RADS category 3 findings accounted for 27% of all ultrasound examinations (N=3.715). Of these, 9.02% (N=335) underwent recommended short-term follow-up. Malignancy was identified in 1.49% of these cases (N=5), with an average tumor size of 13.6 mm at detection. The malignancy rate did not differ significantly between premenopausal and postmenopausal patients (P=0.412). The overall diagnostic yield for malignancy in BI-RADS 3 findings was low, but clinically significant.</p><p><strong>Conclusion: </strong>While the malignancy rate for BI-RADS category 3 findings is low (1.49%), careful monitoring and adherence to follow-up guideline are essential to balance early detection with avoidance of unnecessary biopsies and associated costs.</p>","PeriodicalId":38313,"journal":{"name":"Acta medica academica","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of BI-RADS 3 Ultrasound Findings: the Frequency and Incidence of Malignant Lesions, and Tumor Size.\",\"authors\":\"Hanifa Fejzić, Svjetlana Mujagić, Belkisa Izić\",\"doi\":\"10.5644/ama2006-124.467\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The aim of the research was to determine the frequency of BI-RADS category 3 findings in ultrasound examinations in relation to the total number of patients, the frequency of malignant lesions, and their average size at the time of detection in BI-RADS 3 ultrasound findings.</p><p><strong>Patients and methods: </strong>A cross-sectional study was performed on 335 patients (aged 40-75 years) classified in BI-RADS category 3, at the Tuzla Breast Center, University Clinical Center, in the period from March 2017 to November 2020. A total of 13,760 ultrasound examinations were performed, using a Toshiba Xario 100 ultrasound machine with a 12 MHz linear probe. Patients were divided into premenopausal and postmenopausal groups, excluding patients with symptoms and those with previous breast cancer surgery. The images were stored using the Institution's Pictures Activation and Communication System.</p><p><strong>Results: </strong>BI-RADS category 3 findings accounted for 27% of all ultrasound examinations (N=3.715). Of these, 9.02% (N=335) underwent recommended short-term follow-up. Malignancy was identified in 1.49% of these cases (N=5), with an average tumor size of 13.6 mm at detection. The malignancy rate did not differ significantly between premenopausal and postmenopausal patients (P=0.412). The overall diagnostic yield for malignancy in BI-RADS 3 findings was low, but clinically significant.</p><p><strong>Conclusion: </strong>While the malignancy rate for BI-RADS category 3 findings is low (1.49%), careful monitoring and adherence to follow-up guideline are essential to balance early detection with avoidance of unnecessary biopsies and associated costs.</p>\",\"PeriodicalId\":38313,\"journal\":{\"name\":\"Acta medica academica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta medica academica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5644/ama2006-124.467\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta medica academica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5644/ama2006-124.467","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究BI-RADS 3类超声检查中出现恶性病变的频率与患者总人数、恶性病变的频率以及在BI-RADS 3类超声检查中发现恶性病变时的平均大小的关系。患者和方法:在2017年3月至2020年11月期间,在大学临床中心Tuzla乳房中心,对335名BI-RADS分类为3类的患者(40-75岁)进行了横断面研究。使用东芝Xario 100超声机,12 MHz线性探头,共进行了13760次超声检查。患者分为绝经前组和绝经后组,排除有症状和既往乳腺癌手术的患者。使用该机构的图片激活和通信系统存储图像。结果:BI-RADS 3类发现占所有超声检查的27% (N=3.715)。其中,9.02% (N=335)接受了推荐的短期随访。恶性肿瘤占1.49% (N=5),平均肿瘤大小为13.6 mm。绝经前和绝经后患者的恶性肿瘤发生率无显著差异(P=0.412)。BI-RADS 3结果对恶性肿瘤的总体诊断率较低,但具有临床意义。结论:虽然BI-RADS 3类发现的恶性肿瘤发生率较低(1.49%),但仔细监测并遵守随访指南对于平衡早期发现与避免不必要的活检和相关费用至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of BI-RADS 3 Ultrasound Findings: the Frequency and Incidence of Malignant Lesions, and Tumor Size.

Objective: The aim of the research was to determine the frequency of BI-RADS category 3 findings in ultrasound examinations in relation to the total number of patients, the frequency of malignant lesions, and their average size at the time of detection in BI-RADS 3 ultrasound findings.

Patients and methods: A cross-sectional study was performed on 335 patients (aged 40-75 years) classified in BI-RADS category 3, at the Tuzla Breast Center, University Clinical Center, in the period from March 2017 to November 2020. A total of 13,760 ultrasound examinations were performed, using a Toshiba Xario 100 ultrasound machine with a 12 MHz linear probe. Patients were divided into premenopausal and postmenopausal groups, excluding patients with symptoms and those with previous breast cancer surgery. The images were stored using the Institution's Pictures Activation and Communication System.

Results: BI-RADS category 3 findings accounted for 27% of all ultrasound examinations (N=3.715). Of these, 9.02% (N=335) underwent recommended short-term follow-up. Malignancy was identified in 1.49% of these cases (N=5), with an average tumor size of 13.6 mm at detection. The malignancy rate did not differ significantly between premenopausal and postmenopausal patients (P=0.412). The overall diagnostic yield for malignancy in BI-RADS 3 findings was low, but clinically significant.

Conclusion: While the malignancy rate for BI-RADS category 3 findings is low (1.49%), careful monitoring and adherence to follow-up guideline are essential to balance early detection with avoidance of unnecessary biopsies and associated costs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta medica academica
Acta medica academica Medicine-Medicine (all)
CiteScore
1.90
自引率
0.00%
发文量
21
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信