一种新型体内x射线荧光测量系统的剂量学测试。

IF 1 4区 医学 Q4 ENVIRONMENTAL SCIENCES
Health physics Pub Date : 2025-04-01 Epub Date: 2024-05-27 DOI:10.1097/HP.0000000000001839
Chandler J Burgos, Daniel E Read, Thomas R Grier, Maruf Khan, Marc G Weisskopf, Kathryn M Taylor, Aaron J Specht
{"title":"一种新型体内x射线荧光测量系统的剂量学测试。","authors":"Chandler J Burgos, Daniel E Read, Thomas R Grier, Maruf Khan, Marc G Weisskopf, Kathryn M Taylor, Aaron J Specht","doi":"10.1097/HP.0000000000001839","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Lead exposure poses severe health risks to individuals, impacting cognitive function, growth, learning, and behavior. Current lead detection methods, primarily blood testing and x-ray fluorescence (XRF) of bone, have limitations. This study introduces a novel in vivo XRF measurement system using K-shell energies of lead, addressing limitations of previous methods. The study aimed to characterize beam directionality, subject radiation dose, and operator occupational exposure. Using a high-energy x-ray tube and room-temperature detectors, various parameters were assessed with bone and tissue phantoms. Dose measurements were taken by altering voltage, current, and shielding. Scatter and spatial measurements highlighted increased scatter with bone and tissue presence, emphasizing the safest positions for bystanders and operators. Results exhibited expected dose rate changes with varying parameters, showcasing the impact of bone and tissue on scatter radiation. The system's total body effective dose (with an 8-mm molybdenum shielding indicating minimal risk compared to established public dose limits) for an adult was 1.94 μSv; for a child aged 10 y, it was 3.28 μSv. This system demonstrates promising capabilities for lead exposure monitoring, offering negligible occupational exposure and minimal risk to individuals being scanned. Its safety and efficacy position it as a valuable tool in assessing lead exposure, potentially improving preventive measures.</p>","PeriodicalId":12976,"journal":{"name":"Health physics","volume":"128 4","pages":"273-278"},"PeriodicalIF":1.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11864586/pdf/","citationCount":"0","resultStr":"{\"title\":\"Dosimetry Testing for a New In Vivo X-ray Fluorescence Measurement System.\",\"authors\":\"Chandler J Burgos, Daniel E Read, Thomas R Grier, Maruf Khan, Marc G Weisskopf, Kathryn M Taylor, Aaron J Specht\",\"doi\":\"10.1097/HP.0000000000001839\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>Lead exposure poses severe health risks to individuals, impacting cognitive function, growth, learning, and behavior. Current lead detection methods, primarily blood testing and x-ray fluorescence (XRF) of bone, have limitations. This study introduces a novel in vivo XRF measurement system using K-shell energies of lead, addressing limitations of previous methods. The study aimed to characterize beam directionality, subject radiation dose, and operator occupational exposure. Using a high-energy x-ray tube and room-temperature detectors, various parameters were assessed with bone and tissue phantoms. Dose measurements were taken by altering voltage, current, and shielding. Scatter and spatial measurements highlighted increased scatter with bone and tissue presence, emphasizing the safest positions for bystanders and operators. Results exhibited expected dose rate changes with varying parameters, showcasing the impact of bone and tissue on scatter radiation. The system's total body effective dose (with an 8-mm molybdenum shielding indicating minimal risk compared to established public dose limits) for an adult was 1.94 μSv; for a child aged 10 y, it was 3.28 μSv. This system demonstrates promising capabilities for lead exposure monitoring, offering negligible occupational exposure and minimal risk to individuals being scanned. Its safety and efficacy position it as a valuable tool in assessing lead exposure, potentially improving preventive measures.</p>\",\"PeriodicalId\":12976,\"journal\":{\"name\":\"Health physics\",\"volume\":\"128 4\",\"pages\":\"273-278\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11864586/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Health physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/HP.0000000000001839\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HP.0000000000001839","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/27 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

摘要:铅暴露给个体带来严重的健康风险,影响认知功能、生长、学习和行为。目前的铅检测方法,主要是血液检测和骨骼x射线荧光(XRF),有局限性。本研究介绍了一种利用铅的k壳能的新型体内XRF测量系统,解决了以往方法的局限性。该研究的目的是表征光束方向,受试者辐射剂量和操作人员的职业暴露。利用高能x射线管和室温探测器,用骨骼和组织的模型评估了各种参数。剂量测量是通过改变电压、电流和屏蔽来实现的。散射和空间测量强调了骨骼和组织的存在增加了散射,强调了旁观者和操作人员最安全的位置。结果显示了不同参数下预期剂量率的变化,显示了骨和组织对散射辐射的影响。该系统对成人的总有效剂量(8毫米钼屏蔽表明与既定公共剂量限值相比风险最小)为1.94 μSv;10岁儿童为3.28 μSv。该系统显示出铅暴露监测的良好能力,提供可忽略不计的职业暴露和对被扫描个体的最小风险。其安全性和有效性使其成为评估铅暴露的宝贵工具,可能改善预防措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dosimetry Testing for a New In Vivo X-ray Fluorescence Measurement System.

Abstract: Lead exposure poses severe health risks to individuals, impacting cognitive function, growth, learning, and behavior. Current lead detection methods, primarily blood testing and x-ray fluorescence (XRF) of bone, have limitations. This study introduces a novel in vivo XRF measurement system using K-shell energies of lead, addressing limitations of previous methods. The study aimed to characterize beam directionality, subject radiation dose, and operator occupational exposure. Using a high-energy x-ray tube and room-temperature detectors, various parameters were assessed with bone and tissue phantoms. Dose measurements were taken by altering voltage, current, and shielding. Scatter and spatial measurements highlighted increased scatter with bone and tissue presence, emphasizing the safest positions for bystanders and operators. Results exhibited expected dose rate changes with varying parameters, showcasing the impact of bone and tissue on scatter radiation. The system's total body effective dose (with an 8-mm molybdenum shielding indicating minimal risk compared to established public dose limits) for an adult was 1.94 μSv; for a child aged 10 y, it was 3.28 μSv. This system demonstrates promising capabilities for lead exposure monitoring, offering negligible occupational exposure and minimal risk to individuals being scanned. Its safety and efficacy position it as a valuable tool in assessing lead exposure, potentially improving preventive measures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Health physics
Health physics 医学-公共卫生、环境卫生与职业卫生
CiteScore
4.20
自引率
0.00%
发文量
324
审稿时长
3-8 weeks
期刊介绍: Health Physics, first published in 1958, provides the latest research to a wide variety of radiation safety professionals including health physicists, nuclear chemists, medical physicists, and radiation safety officers with interests in nuclear and radiation science. The Journal allows professionals in these and other disciplines in science and engineering to stay on the cutting edge of scientific and technological advances in the field of radiation safety. The Journal publishes original papers, technical notes, articles on advances in practical applications, editorials, and correspondence. Journal articles report on the latest findings in theoretical, practical, and applied disciplines of epidemiology and radiation effects, radiation biology and radiation science, radiation ecology, and related fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信