改良Yamane技术中两种不同人工晶体的比较。

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY
Indian Journal of Ophthalmology Pub Date : 2025-03-01 Epub Date: 2025-02-26 DOI:10.4103/IJO.IJO_2235_24
Fahri O Aydin, Burakhan K Aksoy, Ali Ceylan, Yusuf B Akbaş, Murat Karapapak, Burçin Kepez Yildiz, Yusuf Yildirim
{"title":"改良Yamane技术中两种不同人工晶体的比较。","authors":"Fahri O Aydin, Burakhan K Aksoy, Ali Ceylan, Yusuf B Akbaş, Murat Karapapak, Burçin Kepez Yildiz, Yusuf Yildirim","doi":"10.4103/IJO.IJO_2235_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare AcrySof MA60AC (Alcon Laboratories, Fort Worth, TX, USA) and Sensar AR40e (Johnson and Johnson, Santa Ana, CA, USA) used in Yamane sutureless scleral fixation technique in terms of visual acuity, refractive stability, and complications.</p><p><strong>Methods: </strong>A retrospective, cross-sectional study was conducted in Istanbul Başakşehir Çam and Sakura City Hospital. Patients were divided into two groups: The first group consisted of patients with MA60AC lenses, while the second group consisted of patients with AR40e. Aphakic patients who underwent secondary intraocular lens (IOL) implantation and had postoperative minimum 3-month follow-up records were included. Visual acuity, refractive outcomes, perioperative and postoperative complications were recorded.</p><p><strong>Results: </strong>Forty-nine patients were included in the study. Twenty-two patients were in the first group and 27 patients were in the second group. Age, gender, and follow-up time were similar between groups (P = 0.546, 0.213, and 0.347, respectively). The median lenticular astigmatism value was 0.86 (0.08-2.11) D in group 1 and 0.99 (0.31-2.96) D in group 2 (P = 0.898). There was no significant difference between groups in terms of visual acuity, spherical, cylindrical, and spherical equivalent values (P = 0.752, 0.375, 0.073, and 0.949, respectively). In group 1, a haptic tip fracture and optic-haptic separation were observed perioperatively. Optic-haptic junction separation was observed in one patient in group 1 on postoperative day 1. In group 1, epiretinal membrane development was significantly higher (P = 0.019).</p><p><strong>Conclusions: </strong>Both AcrySof MA60AC and Sensar AR40e IOLs via the modified Yamane technique yielded favorable and predictable outcomes. Although statistically insignificant, haptic problems were more common in the first group.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":"73 3","pages":"416-421"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11994166/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of two different intraocular lenses used in the modified Yamane technique.\",\"authors\":\"Fahri O Aydin, Burakhan K Aksoy, Ali Ceylan, Yusuf B Akbaş, Murat Karapapak, Burçin Kepez Yildiz, Yusuf Yildirim\",\"doi\":\"10.4103/IJO.IJO_2235_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare AcrySof MA60AC (Alcon Laboratories, Fort Worth, TX, USA) and Sensar AR40e (Johnson and Johnson, Santa Ana, CA, USA) used in Yamane sutureless scleral fixation technique in terms of visual acuity, refractive stability, and complications.</p><p><strong>Methods: </strong>A retrospective, cross-sectional study was conducted in Istanbul Başakşehir Çam and Sakura City Hospital. Patients were divided into two groups: The first group consisted of patients with MA60AC lenses, while the second group consisted of patients with AR40e. Aphakic patients who underwent secondary intraocular lens (IOL) implantation and had postoperative minimum 3-month follow-up records were included. Visual acuity, refractive outcomes, perioperative and postoperative complications were recorded.</p><p><strong>Results: </strong>Forty-nine patients were included in the study. Twenty-two patients were in the first group and 27 patients were in the second group. Age, gender, and follow-up time were similar between groups (P = 0.546, 0.213, and 0.347, respectively). The median lenticular astigmatism value was 0.86 (0.08-2.11) D in group 1 and 0.99 (0.31-2.96) D in group 2 (P = 0.898). There was no significant difference between groups in terms of visual acuity, spherical, cylindrical, and spherical equivalent values (P = 0.752, 0.375, 0.073, and 0.949, respectively). In group 1, a haptic tip fracture and optic-haptic separation were observed perioperatively. Optic-haptic junction separation was observed in one patient in group 1 on postoperative day 1. In group 1, epiretinal membrane development was significantly higher (P = 0.019).</p><p><strong>Conclusions: </strong>Both AcrySof MA60AC and Sensar AR40e IOLs via the modified Yamane technique yielded favorable and predictable outcomes. Although statistically insignificant, haptic problems were more common in the first group.</p>\",\"PeriodicalId\":13329,\"journal\":{\"name\":\"Indian Journal of Ophthalmology\",\"volume\":\"73 3\",\"pages\":\"416-421\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11994166/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/IJO.IJO_2235_24\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_2235_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较AcrySof MA60AC (Alcon Laboratories, Fort Worth, TX, USA)和Sensar AR40e (Johnson and Johnson, Santa Ana, CA, USA)在Yamane无缝线巩膜固定技术中的视力、屈光稳定性和并发症。方法:回顾性、横断面研究在伊斯坦布尔医院Çam和Sakura市医院进行。患者分为两组:第一组为MA60AC隐形眼镜患者,第二组为AR40e隐形眼镜患者。接受二次人工晶状体(IOL)植入术且术后至少随访3个月的无晶状体患者被纳入研究对象。记录视力、屈光情况、围手术期及术后并发症。结果:49例患者纳入研究。第一组22例,第二组27例。年龄、性别、随访时间组间差异无统计学意义(P分别为0.546、0.213、0.347)。第1组中位散光值为0.86 (0.08 ~ 2.11)D,第2组中位散光值为0.99 (0.31 ~ 2.96)D (P = 0.898)。两组之间的视敏度、球形、圆柱形和球形等效值差异无统计学意义(P值分别为0.752、0.375、0.073和0.949)。第一组术中观察触觉尖端骨折及光-触觉分离。1组术后第1天有1例患者出现视-触觉结分离。1组视网膜前膜发育显著增高(P = 0.019)。结论:AcrySof MA60AC和Sensar AR40e人工晶状体经改良Yamane技术均可获得良好且可预测的结果。虽然统计上不显著,但触觉问题在第一组中更常见。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of two different intraocular lenses used in the modified Yamane technique.

Purpose: To compare AcrySof MA60AC (Alcon Laboratories, Fort Worth, TX, USA) and Sensar AR40e (Johnson and Johnson, Santa Ana, CA, USA) used in Yamane sutureless scleral fixation technique in terms of visual acuity, refractive stability, and complications.

Methods: A retrospective, cross-sectional study was conducted in Istanbul Başakşehir Çam and Sakura City Hospital. Patients were divided into two groups: The first group consisted of patients with MA60AC lenses, while the second group consisted of patients with AR40e. Aphakic patients who underwent secondary intraocular lens (IOL) implantation and had postoperative minimum 3-month follow-up records were included. Visual acuity, refractive outcomes, perioperative and postoperative complications were recorded.

Results: Forty-nine patients were included in the study. Twenty-two patients were in the first group and 27 patients were in the second group. Age, gender, and follow-up time were similar between groups (P = 0.546, 0.213, and 0.347, respectively). The median lenticular astigmatism value was 0.86 (0.08-2.11) D in group 1 and 0.99 (0.31-2.96) D in group 2 (P = 0.898). There was no significant difference between groups in terms of visual acuity, spherical, cylindrical, and spherical equivalent values (P = 0.752, 0.375, 0.073, and 0.949, respectively). In group 1, a haptic tip fracture and optic-haptic separation were observed perioperatively. Optic-haptic junction separation was observed in one patient in group 1 on postoperative day 1. In group 1, epiretinal membrane development was significantly higher (P = 0.019).

Conclusions: Both AcrySof MA60AC and Sensar AR40e IOLs via the modified Yamane technique yielded favorable and predictable outcomes. Although statistically insignificant, haptic problems were more common in the first group.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信