{"title":"利用虚拟韧带实现肌肉驱动的全膝关节置换稳定性。","authors":"Alexandre Galley, Emma Donnelly, Ilya Borukhov, Brent Lanting, Ryan Willing","doi":"10.3390/bioengineering12020112","DOIUrl":null,"url":null,"abstract":"<p><p>Knee joint stability comprises passive (ligaments), active (muscles), and static (articular congruency) contributors. The stability of total knee replacement (TKR) implants can be assessed pre-clinically using joint motion simulators. However, contemporary testing methods with these platforms do not accurately reproduce the biomechanical contributions of passive stabilizers, active stabilizers, or both. A key component of joint stability is therefore missing from laxity tests. A recently developed muscle actuator system (MAS) pairs the quadriceps-driven motion capabilities of an Oxford knee simulator with the prescribed displacements and laxity testing methods of a VIVO robotic knee testing system, which also includes virtual ligament capabilities. Using a TKR-embedded non-cadaveric joint analogue, TKR with two different virtual ligament models were compared to TKR with no active ligaments. Laxity limits were then obtained for both developed models using the conventional style of laxity testing (the VIVO's force/displacement control) and compared with results obtained under similar conditions with the MAS (gravity-dependent muscle control). Differences in joint control methods identified the need for muscle forces providing active joint stability, while differences in the effects of the virtual ligament models identified the importance of physiological representations of collateral ligaments during testing.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"12 2","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11851665/pdf/","citationCount":"0","resultStr":"{\"title\":\"Muscle-Driven Total Knee Replacement Stability with Virtual Ligaments.\",\"authors\":\"Alexandre Galley, Emma Donnelly, Ilya Borukhov, Brent Lanting, Ryan Willing\",\"doi\":\"10.3390/bioengineering12020112\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Knee joint stability comprises passive (ligaments), active (muscles), and static (articular congruency) contributors. The stability of total knee replacement (TKR) implants can be assessed pre-clinically using joint motion simulators. However, contemporary testing methods with these platforms do not accurately reproduce the biomechanical contributions of passive stabilizers, active stabilizers, or both. A key component of joint stability is therefore missing from laxity tests. A recently developed muscle actuator system (MAS) pairs the quadriceps-driven motion capabilities of an Oxford knee simulator with the prescribed displacements and laxity testing methods of a VIVO robotic knee testing system, which also includes virtual ligament capabilities. Using a TKR-embedded non-cadaveric joint analogue, TKR with two different virtual ligament models were compared to TKR with no active ligaments. Laxity limits were then obtained for both developed models using the conventional style of laxity testing (the VIVO's force/displacement control) and compared with results obtained under similar conditions with the MAS (gravity-dependent muscle control). Differences in joint control methods identified the need for muscle forces providing active joint stability, while differences in the effects of the virtual ligament models identified the importance of physiological representations of collateral ligaments during testing.</p>\",\"PeriodicalId\":8874,\"journal\":{\"name\":\"Bioengineering\",\"volume\":\"12 2\",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2025-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11851665/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bioengineering12020112\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering12020112","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Muscle-Driven Total Knee Replacement Stability with Virtual Ligaments.
Knee joint stability comprises passive (ligaments), active (muscles), and static (articular congruency) contributors. The stability of total knee replacement (TKR) implants can be assessed pre-clinically using joint motion simulators. However, contemporary testing methods with these platforms do not accurately reproduce the biomechanical contributions of passive stabilizers, active stabilizers, or both. A key component of joint stability is therefore missing from laxity tests. A recently developed muscle actuator system (MAS) pairs the quadriceps-driven motion capabilities of an Oxford knee simulator with the prescribed displacements and laxity testing methods of a VIVO robotic knee testing system, which also includes virtual ligament capabilities. Using a TKR-embedded non-cadaveric joint analogue, TKR with two different virtual ligament models were compared to TKR with no active ligaments. Laxity limits were then obtained for both developed models using the conventional style of laxity testing (the VIVO's force/displacement control) and compared with results obtained under similar conditions with the MAS (gravity-dependent muscle control). Differences in joint control methods identified the need for muscle forces providing active joint stability, while differences in the effects of the virtual ligament models identified the importance of physiological representations of collateral ligaments during testing.
期刊介绍:
Aims
Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal:
● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings.
● Manuscripts regarding research proposals and research ideas will be particularly welcomed.
● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds.
Scope
● Bionics and biological cybernetics: implantology; bio–abio interfaces
● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices
● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc.
● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology
● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering
● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation
● Translational bioengineering