压阻式微悬臂传感器的轻量化共振跟踪系统

IF 4.7 Q2 NANOSCIENCE & NANOTECHNOLOGY
Andi Setiono,  Nelfyenny,  Suryadi,  Qomaruddin, Wilson Ombati Nyang’au, Erwin Peiner
{"title":"压阻式微悬臂传感器的轻量化共振跟踪系统","authors":"Andi Setiono,&nbsp; Nelfyenny,&nbsp; Suryadi,&nbsp; Qomaruddin,&nbsp;Wilson Ombati Nyang’au,&nbsp;Erwin Peiner","doi":"10.1186/s40486-025-00221-9","DOIUrl":null,"url":null,"abstract":"<div><p>A lightweight resonance tracking system designed for precise monitoring of resonant frequency shifts in microcantilever sensors is introduced. The system integrates a Phase-Locked Loop (PLL)-based technique with a Python-based interface for real-time control and visualization. A tipless microcantilever sensor was tested under relative humidity (RH) conditions ranging from 63% to 90% to experimentally validate the system. The system demonstrated a sensitivity of 1.082 Hz/% RH and a Limit of Detection (LOD) of 1.89% RH. The silicon dioxide (<span>\\(SiO_2\\)</span>) surface of the microcantilever is hygroscopic, allowing water vapor adsorption and causing frequency shifts. This effect is more pronounced at high humidity levels (&gt;80% RH) due to multilayer adsorption. These results confirm the reliability and precision of the system in detecting environmental changes. The findings highlight the potential of the developed system for applications in environmental monitoring, healthcare diagnostics, and industrial chemical sensing.</p></div>","PeriodicalId":704,"journal":{"name":"Micro and Nano Systems Letters","volume":"13 1","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://mnsl-journal.springeropen.com/counter/pdf/10.1186/s40486-025-00221-9","citationCount":"0","resultStr":"{\"title\":\"A lightweight resonance tracking system for piezoresistive microcantilever sensors\",\"authors\":\"Andi Setiono,&nbsp; Nelfyenny,&nbsp; Suryadi,&nbsp; Qomaruddin,&nbsp;Wilson Ombati Nyang’au,&nbsp;Erwin Peiner\",\"doi\":\"10.1186/s40486-025-00221-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A lightweight resonance tracking system designed for precise monitoring of resonant frequency shifts in microcantilever sensors is introduced. The system integrates a Phase-Locked Loop (PLL)-based technique with a Python-based interface for real-time control and visualization. A tipless microcantilever sensor was tested under relative humidity (RH) conditions ranging from 63% to 90% to experimentally validate the system. The system demonstrated a sensitivity of 1.082 Hz/% RH and a Limit of Detection (LOD) of 1.89% RH. The silicon dioxide (<span>\\\\(SiO_2\\\\)</span>) surface of the microcantilever is hygroscopic, allowing water vapor adsorption and causing frequency shifts. This effect is more pronounced at high humidity levels (&gt;80% RH) due to multilayer adsorption. These results confirm the reliability and precision of the system in detecting environmental changes. The findings highlight the potential of the developed system for applications in environmental monitoring, healthcare diagnostics, and industrial chemical sensing.</p></div>\",\"PeriodicalId\":704,\"journal\":{\"name\":\"Micro and Nano Systems Letters\",\"volume\":\"13 1\",\"pages\":\"\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-02-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://mnsl-journal.springeropen.com/counter/pdf/10.1186/s40486-025-00221-9\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Micro and Nano Systems Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s40486-025-00221-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"NANOSCIENCE & NANOTECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micro and Nano Systems Letters","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s40486-025-00221-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NANOSCIENCE & NANOTECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种用于精确监测微悬臂传感器谐振频移的轻量化谐振跟踪系统。该系统集成了基于锁相环(PLL)的技术和基于python的接口,用于实时控制和可视化。在相对湿度(RH)为63% to 90% to experimentally validate the system. The system demonstrated a sensitivity of 1.082 Hz/% RH and a Limit of Detection (LOD) of 1.89% RH. The silicon dioxide (\(SiO_2\)) surface of the microcantilever is hygroscopic, allowing water vapor adsorption and causing frequency shifts. This effect is more pronounced at high humidity levels (>80% RH) due to multilayer adsorption. These results confirm the reliability and precision of the system in detecting environmental changes. The findings highlight the potential of the developed system for applications in environmental monitoring, healthcare diagnostics, and industrial chemical sensing.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A lightweight resonance tracking system for piezoresistive microcantilever sensors

A lightweight resonance tracking system designed for precise monitoring of resonant frequency shifts in microcantilever sensors is introduced. The system integrates a Phase-Locked Loop (PLL)-based technique with a Python-based interface for real-time control and visualization. A tipless microcantilever sensor was tested under relative humidity (RH) conditions ranging from 63% to 90% to experimentally validate the system. The system demonstrated a sensitivity of 1.082 Hz/% RH and a Limit of Detection (LOD) of 1.89% RH. The silicon dioxide (\(SiO_2\)) surface of the microcantilever is hygroscopic, allowing water vapor adsorption and causing frequency shifts. This effect is more pronounced at high humidity levels (>80% RH) due to multilayer adsorption. These results confirm the reliability and precision of the system in detecting environmental changes. The findings highlight the potential of the developed system for applications in environmental monitoring, healthcare diagnostics, and industrial chemical sensing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Micro and Nano Systems Letters
Micro and Nano Systems Letters Engineering-Biomedical Engineering
CiteScore
10.60
自引率
5.60%
发文量
16
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信