儿童恒磨牙预制与定制氧化锆冠抗断性的体外研究。

IF 3.1 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Thikrayat Bani-Hani, Rami S Al-Fodeh, Ahed M Al-Wahadni, Elham S Abu-Alhaija, Mahmoud Al-Hakam
{"title":"儿童恒磨牙预制与定制氧化锆冠抗断性的体外研究。","authors":"Thikrayat Bani-Hani, Rami S Al-Fodeh, Ahed M Al-Wahadni, Elham S Abu-Alhaija, Mahmoud Al-Hakam","doi":"10.3390/dj13020064","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Recently, the demand for esthetic restorations has grown dramatically and extended into the pediatric population. The prefabricated zirconia crowns (PZCs) and custom-made zirconia crowns (CZCs) are new esthetic options in pediatric dentistry. However, they are still inadequately tested for use in children. Aim: To determine the fracture resistance and failure mode of the PZC in comparison to the CZC. <b>Materials and Methods:</b> In this in-vitro study, thirty cobalt-chromium dies were fabricated by scanning the negative replica of a prefabricated lower first permanent molar zirconia crown. CZCs were designed and milled using two different zirconia brands: Ceramill Zolid-FX (FX) and the Highly-Translucent (HT) zirconia. Dies were randomly assigned to receive either a PZC or a CZC (n = 10 in each group). All crowns were cemented on their respective dies using glass ionomer cement. Following artificial aging, all specimens were loaded to failure. Fracture mode analysis was performed. One-way ANOVA and Bonferroni post-hoc test were used for multiple comparisons across the groups. The significant level was set at <i>p</i> ≤ 0.05. <b>Results:</b> HT zirconia had a significantly higher fracture load compared to other groups (<i>p</i> < 0.05). The mean fracture resistance values were: (3087 ± 385) N for HT zirconia, (2633 ± 300) N for PZCs, and (2483 ± 381) N for FX, with no statistically significant difference in fracture strengths between PZCs and FX. <b>Conclusions:</b> HT zirconia crowns showed the highest fracture resistance amongst all groups. The fracture loads of tested crowns exceeded the maximum posterior biteforce. When placed in permanent molars, PZC are expected to perform well under masticatory forces in children.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"13 2","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11854477/pdf/","citationCount":"0","resultStr":"{\"title\":\"An In-Vitro Investigation into the Fracture Resistance of Prefabricated and Custom-Made Zirconia Crowns for Permanent Molars in Children.\",\"authors\":\"Thikrayat Bani-Hani, Rami S Al-Fodeh, Ahed M Al-Wahadni, Elham S Abu-Alhaija, Mahmoud Al-Hakam\",\"doi\":\"10.3390/dj13020064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background:</b> Recently, the demand for esthetic restorations has grown dramatically and extended into the pediatric population. The prefabricated zirconia crowns (PZCs) and custom-made zirconia crowns (CZCs) are new esthetic options in pediatric dentistry. However, they are still inadequately tested for use in children. Aim: To determine the fracture resistance and failure mode of the PZC in comparison to the CZC. <b>Materials and Methods:</b> In this in-vitro study, thirty cobalt-chromium dies were fabricated by scanning the negative replica of a prefabricated lower first permanent molar zirconia crown. CZCs were designed and milled using two different zirconia brands: Ceramill Zolid-FX (FX) and the Highly-Translucent (HT) zirconia. Dies were randomly assigned to receive either a PZC or a CZC (n = 10 in each group). All crowns were cemented on their respective dies using glass ionomer cement. Following artificial aging, all specimens were loaded to failure. Fracture mode analysis was performed. One-way ANOVA and Bonferroni post-hoc test were used for multiple comparisons across the groups. The significant level was set at <i>p</i> ≤ 0.05. <b>Results:</b> HT zirconia had a significantly higher fracture load compared to other groups (<i>p</i> < 0.05). The mean fracture resistance values were: (3087 ± 385) N for HT zirconia, (2633 ± 300) N for PZCs, and (2483 ± 381) N for FX, with no statistically significant difference in fracture strengths between PZCs and FX. <b>Conclusions:</b> HT zirconia crowns showed the highest fracture resistance amongst all groups. The fracture loads of tested crowns exceeded the maximum posterior biteforce. When placed in permanent molars, PZC are expected to perform well under masticatory forces in children.</p>\",\"PeriodicalId\":11269,\"journal\":{\"name\":\"Dentistry Journal\",\"volume\":\"13 2\",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-01-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11854477/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj13020064\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj13020064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:最近,对美学修复的需求急剧增长,并扩展到儿科人群。预制氧化锆冠(PZCs)和定制氧化锆冠(CZCs)是儿科牙科新的美学选择。然而,它们在儿童中的使用仍然没有得到充分的测试。目的:确定PZC与CZC的抗断裂能力和破坏模式。材料和方法:在这项体外研究中,通过扫描预制的下第一永久磨牙氧化锆冠的阴性复制品来制作30个钴铬模具。使用两种不同的氧化锆品牌:Ceramill Zolid-FX (FX)和高半透明(HT)氧化锆设计和研磨CZCs。患者被随机分配接受PZC或CZC(每组n = 10)。所有的冠都用玻璃离子水泥在各自的模具上粘接。人工老化后,所有试件均加载破坏。进行断裂模式分析。组间多组比较采用单因素方差分析和Bonferroni事后检验。p≤0.05为显著水平。结果:高温氧化锆组骨折负荷明显高于其他各组(p < 0.05)。平均断裂阻力值为:HT氧化锆为(3087±385)N, PZCs为(2633±300)N, FX为(2483±381)N, PZCs与FX的断裂强度无统计学差异。结论:HT氧化锆冠的抗折性最高。试验冠的断裂载荷超过最大后牙合力。当放置在恒磨牙上时,PZC有望在儿童咀嚼力下表现良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An In-Vitro Investigation into the Fracture Resistance of Prefabricated and Custom-Made Zirconia Crowns for Permanent Molars in Children.

Background: Recently, the demand for esthetic restorations has grown dramatically and extended into the pediatric population. The prefabricated zirconia crowns (PZCs) and custom-made zirconia crowns (CZCs) are new esthetic options in pediatric dentistry. However, they are still inadequately tested for use in children. Aim: To determine the fracture resistance and failure mode of the PZC in comparison to the CZC. Materials and Methods: In this in-vitro study, thirty cobalt-chromium dies were fabricated by scanning the negative replica of a prefabricated lower first permanent molar zirconia crown. CZCs were designed and milled using two different zirconia brands: Ceramill Zolid-FX (FX) and the Highly-Translucent (HT) zirconia. Dies were randomly assigned to receive either a PZC or a CZC (n = 10 in each group). All crowns were cemented on their respective dies using glass ionomer cement. Following artificial aging, all specimens were loaded to failure. Fracture mode analysis was performed. One-way ANOVA and Bonferroni post-hoc test were used for multiple comparisons across the groups. The significant level was set at p ≤ 0.05. Results: HT zirconia had a significantly higher fracture load compared to other groups (p < 0.05). The mean fracture resistance values were: (3087 ± 385) N for HT zirconia, (2633 ± 300) N for PZCs, and (2483 ± 381) N for FX, with no statistically significant difference in fracture strengths between PZCs and FX. Conclusions: HT zirconia crowns showed the highest fracture resistance amongst all groups. The fracture loads of tested crowns exceeded the maximum posterior biteforce. When placed in permanent molars, PZC are expected to perform well under masticatory forces in children.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信