一种用于定量脂质、脂质混合物和生物膜中不饱和脂肪酸含量的小型碘值测定法。

IF 1.8 4区 医学 Q4 BIOCHEMISTRY & MOLECULAR BIOLOGY
Lipids Pub Date : 2025-02-23 DOI:10.1002/lipd.12438
Maria Monserrat Roman-Lara, Katie J Chong, Roslyn M Bill, Alan D Goddard
{"title":"一种用于定量脂质、脂质混合物和生物膜中不饱和脂肪酸含量的小型碘值测定法。","authors":"Maria Monserrat Roman-Lara, Katie J Chong, Roslyn M Bill, Alan D Goddard","doi":"10.1002/lipd.12438","DOIUrl":null,"url":null,"abstract":"<p><p>Various methods exist for identifying and quantifying lipid unsaturation, including mass spectrometry and Raman spectroscopy. A disadvantage of these existing approaches is the need for sophisticated equipment and software, placing them beyond the means of many laboratories. The iodine value (IV) is a colorimetric unsaturation index; however, it uses iodine monochloride, a hazardous chemical, and considerable amounts of sample. Here, we demonstrate the first use of a miniaturized IV method that requires only milliliter quantities of hazardous chemicals and sample sizes such that it is feasible to assay biological membranes. Briefly, lipids are exposed to iodine monochloride, resulting in the replacement of unsaturated bonds with di-halogenated single bonds. Potassium iodide then reacts with unreacted iodine monochloride forming I<sub>2</sub>, which is quantified through titration with sodium thiosulfate. To demonstrate the biological relevance of our assay, membrane lipids of Escherichia coli grown at 30, 37, and 42°C were analyzed, with IV increasing as temperature decreased, as would be expected. Importantly, multiple samples could be rapidly and simultaneously analyzed in a reproducible assay that did not require sophisticated equipment or data analysis methods. Our miniaturized IV assay will benefit laboratories with limited access to sophisticated equipment and enable the rapid determination of lipid unsaturation in milligram-scale samples.</p>","PeriodicalId":18086,"journal":{"name":"Lipids","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A miniaturized iodine value assay for quantifying the unsaturated fatty acid content of lipids, lipid mixtures, and biological membranes.\",\"authors\":\"Maria Monserrat Roman-Lara, Katie J Chong, Roslyn M Bill, Alan D Goddard\",\"doi\":\"10.1002/lipd.12438\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Various methods exist for identifying and quantifying lipid unsaturation, including mass spectrometry and Raman spectroscopy. A disadvantage of these existing approaches is the need for sophisticated equipment and software, placing them beyond the means of many laboratories. The iodine value (IV) is a colorimetric unsaturation index; however, it uses iodine monochloride, a hazardous chemical, and considerable amounts of sample. Here, we demonstrate the first use of a miniaturized IV method that requires only milliliter quantities of hazardous chemicals and sample sizes such that it is feasible to assay biological membranes. Briefly, lipids are exposed to iodine monochloride, resulting in the replacement of unsaturated bonds with di-halogenated single bonds. Potassium iodide then reacts with unreacted iodine monochloride forming I<sub>2</sub>, which is quantified through titration with sodium thiosulfate. To demonstrate the biological relevance of our assay, membrane lipids of Escherichia coli grown at 30, 37, and 42°C were analyzed, with IV increasing as temperature decreased, as would be expected. Importantly, multiple samples could be rapidly and simultaneously analyzed in a reproducible assay that did not require sophisticated equipment or data analysis methods. Our miniaturized IV assay will benefit laboratories with limited access to sophisticated equipment and enable the rapid determination of lipid unsaturation in milligram-scale samples.</p>\",\"PeriodicalId\":18086,\"journal\":{\"name\":\"Lipids\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lipids\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/lipd.12438\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lipids","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/lipd.12438","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

存在多种方法来鉴定和定量脂质不饱和,包括质谱法和拉曼光谱法。这些现有方法的一个缺点是需要复杂的设备和软件,使它们超出了许多实验室的能力。碘值(IV)为比色不饱和指数;然而,它使用了一氯化碘,一种危险的化学物质,并使用了大量的样品。在这里,我们演示了小型化IV方法的首次使用,该方法只需要毫升量的危险化学品和样本量,因此可以测定生物膜。简而言之,脂质暴露于一氯化碘,导致不饱和键被二卤化单键取代。然后,碘化钾与未反应的一氯化碘反应形成I2, I2通过硫代硫酸钠滴定来定量。为了证明我们实验的生物学相关性,我们分析了在30,37和42°C下生长的大肠杆菌的膜脂,IV随着温度的降低而增加,正如预期的那样。重要的是,多个样品可以在不需要复杂设备或数据分析方法的可重复分析中快速同时分析。我们的小型IV分析将使实验室受益于有限的精密设备,并能够快速测定毫克级样品中的脂质不饱和。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A miniaturized iodine value assay for quantifying the unsaturated fatty acid content of lipids, lipid mixtures, and biological membranes.

Various methods exist for identifying and quantifying lipid unsaturation, including mass spectrometry and Raman spectroscopy. A disadvantage of these existing approaches is the need for sophisticated equipment and software, placing them beyond the means of many laboratories. The iodine value (IV) is a colorimetric unsaturation index; however, it uses iodine monochloride, a hazardous chemical, and considerable amounts of sample. Here, we demonstrate the first use of a miniaturized IV method that requires only milliliter quantities of hazardous chemicals and sample sizes such that it is feasible to assay biological membranes. Briefly, lipids are exposed to iodine monochloride, resulting in the replacement of unsaturated bonds with di-halogenated single bonds. Potassium iodide then reacts with unreacted iodine monochloride forming I2, which is quantified through titration with sodium thiosulfate. To demonstrate the biological relevance of our assay, membrane lipids of Escherichia coli grown at 30, 37, and 42°C were analyzed, with IV increasing as temperature decreased, as would be expected. Importantly, multiple samples could be rapidly and simultaneously analyzed in a reproducible assay that did not require sophisticated equipment or data analysis methods. Our miniaturized IV assay will benefit laboratories with limited access to sophisticated equipment and enable the rapid determination of lipid unsaturation in milligram-scale samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lipids
Lipids 生物-生化与分子生物学
CiteScore
4.20
自引率
5.30%
发文量
33
审稿时长
4-8 weeks
期刊介绍: Lipids is a journal of the American Oil Chemists'' Society (AOCS) that focuses on publishing high-quality peer-reviewed papers and invited reviews in the general area of lipid research, including chemistry, biochemistry, clinical nutrition, and metabolism. In addition, Lipids publishes papers establishing novel methods for addressing research questions in the field of lipid research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信