{"title":"接近检出限时的荧光显微镜制备规程。","authors":"Rebecca McCerery, Lewis Hall, Jithin Omanakuttan, Hui Zhi Chai, James Lawrence, John Woodward, David A Pearce","doi":"10.1093/lambio/ovaf026","DOIUrl":null,"url":null,"abstract":"<p><p>Working with low density, low biomass material can be challenging, especially when working near the detection limit. Although background contamination is a universal consideration in microbiological research, its impact is increased when the cells under assessment approach the same concentration as the background contamination. The aim of this work was to identify and remove laboratory sources of background contamination in the cell mounting process for epifluorescence microscopy to improve the reliability of cell counting for low biomass samples. Microscope slides and coverslips were assessed before and after autoclaving, washing with detergent and rinsing with ethanol solution. The solutions used in sample mounting; 4',6-diamidino-2-phenylindole, phosphate buffered saline, and immersion oil, were tested before and after autoclaving as well as both single and triple filtering with a 0.2 µm membrane filter. Using a combination of detergent and ethanol rinses of glassware and triple filtering of all solutions, we were able to reduce the background contamination by almost two orders of magnitude, down from 1 × 104(±4.3 × 103) cells to 302(±312) cells per filter paper. This method was then validated with low biomass glacial sediment samples from Renardbreen, Svalbard, with cell concentrations of 1.8 × 105(±2.9 × 104) cells g-1, close to the reported detection limit of epifluorescence microscopy.</p>","PeriodicalId":17962,"journal":{"name":"Letters in Applied Microbiology","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preparation protocol for epifluorescence microscopy when working close to the detection limit.\",\"authors\":\"Rebecca McCerery, Lewis Hall, Jithin Omanakuttan, Hui Zhi Chai, James Lawrence, John Woodward, David A Pearce\",\"doi\":\"10.1093/lambio/ovaf026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Working with low density, low biomass material can be challenging, especially when working near the detection limit. Although background contamination is a universal consideration in microbiological research, its impact is increased when the cells under assessment approach the same concentration as the background contamination. The aim of this work was to identify and remove laboratory sources of background contamination in the cell mounting process for epifluorescence microscopy to improve the reliability of cell counting for low biomass samples. Microscope slides and coverslips were assessed before and after autoclaving, washing with detergent and rinsing with ethanol solution. The solutions used in sample mounting; 4',6-diamidino-2-phenylindole, phosphate buffered saline, and immersion oil, were tested before and after autoclaving as well as both single and triple filtering with a 0.2 µm membrane filter. Using a combination of detergent and ethanol rinses of glassware and triple filtering of all solutions, we were able to reduce the background contamination by almost two orders of magnitude, down from 1 × 104(±4.3 × 103) cells to 302(±312) cells per filter paper. This method was then validated with low biomass glacial sediment samples from Renardbreen, Svalbard, with cell concentrations of 1.8 × 105(±2.9 × 104) cells g-1, close to the reported detection limit of epifluorescence microscopy.</p>\",\"PeriodicalId\":17962,\"journal\":{\"name\":\"Letters in Applied Microbiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Letters in Applied Microbiology\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1093/lambio/ovaf026\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Letters in Applied Microbiology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1093/lambio/ovaf026","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

处理低密度、低生物量的材料可能具有挑战性,特别是在接近检测极限的情况下。虽然背景污染是微生物学研究中普遍考虑的因素,但当被评估的细胞接近与背景污染相同的浓度时,其影响会增加。这项工作的目的是识别和消除在荧光显微镜细胞安装过程中的实验室背景污染源,以提高低生物量样品细胞计数的可靠性。显微镜载玻片和盖片在高压灭菌、用洗涤剂洗涤和用乙醇溶液冲洗前后进行评估。样品安装中使用的溶液;4′,6-二氨基-2-苯基吲哚,磷酸盐缓冲盐水和浸泡油,在高压灭菌前后进行测试,并使用0.2µm膜过滤器进行单次和三次过滤。结合使用清洁剂和乙醇冲洗玻璃器皿,并对所有溶液进行三次过滤,我们能够将背景污染减少近两个数量级,从每份滤纸1×104(±4.3×103)细胞减少到302(±312)细胞。然后用来自斯瓦尔巴群岛Renardbreen的低生物量冰川沉积物样品验证该方法,细胞浓度为1.8×105(±2.9×104) cells g-1,接近报道的荧光显微镜检测限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preparation protocol for epifluorescence microscopy when working close to the detection limit.

Working with low density, low biomass material can be challenging, especially when working near the detection limit. Although background contamination is a universal consideration in microbiological research, its impact is increased when the cells under assessment approach the same concentration as the background contamination. The aim of this work was to identify and remove laboratory sources of background contamination in the cell mounting process for epifluorescence microscopy to improve the reliability of cell counting for low biomass samples. Microscope slides and coverslips were assessed before and after autoclaving, washing with detergent and rinsing with ethanol solution. The solutions used in sample mounting; 4',6-diamidino-2-phenylindole, phosphate buffered saline, and immersion oil, were tested before and after autoclaving as well as both single and triple filtering with a 0.2 µm membrane filter. Using a combination of detergent and ethanol rinses of glassware and triple filtering of all solutions, we were able to reduce the background contamination by almost two orders of magnitude, down from 1 × 104(±4.3 × 103) cells to 302(±312) cells per filter paper. This method was then validated with low biomass glacial sediment samples from Renardbreen, Svalbard, with cell concentrations of 1.8 × 105(±2.9 × 104) cells g-1, close to the reported detection limit of epifluorescence microscopy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Letters in Applied Microbiology
Letters in Applied Microbiology 工程技术-生物工程与应用微生物
CiteScore
4.40
自引率
4.20%
发文量
225
审稿时长
3.3 months
期刊介绍: Journal of & Letters in Applied Microbiology are two of the flagship research journals of the Society for Applied Microbiology (SfAM). For more than 75 years they have been publishing top quality research and reviews in the broad field of applied microbiology. The journals are provided to all SfAM members as well as having a global online readership totalling more than 500,000 downloads per year in more than 200 countries. Submitting authors can expect fast decision and publication times, averaging 33 days to first decision and 34 days from acceptance to online publication. There are no page charges.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信