Mateusz Dworak, Kamila Stolcman-Mrugała, Zuzanna Gałuszka, Karolina Pasierb, Robert Chrzan, Jacek Składzień
{"title":"计算机断层扫描与减少金属伪影在眶内异物位置的作用-一个病例报告。","authors":"Mateusz Dworak, Kamila Stolcman-Mrugała, Zuzanna Gałuszka, Karolina Pasierb, Robert Chrzan, Jacek Składzień","doi":"10.24425/fmc.2024.152175","DOIUrl":null,"url":null,"abstract":"<p><p>Intraorbital foreign bodies still remain an unsolved and serious diagnostic problem. Due to the complicated anatomical orbital structure, both the diagnosis and treatment of these injuries are considered to be one of the most challenging. We present a case of a metallic foreign body (a bullet) imbeded in the orbit of a 10-year-old boy. Only after performing computed tomography imaging using the metal artifacts reduction algorithm it was possible to properly localize the foreign body. The issue of intraorbital foreign bodies is interdisciplinary and requires the co-operation between many specialists, including ophthalmologists, otorhinolaryngologists and radiologists.</p>","PeriodicalId":12106,"journal":{"name":"Folia medica Cracoviensia","volume":"64 3","pages":"143-153"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The usefulness of computed tomography with the reduction of metal artifacts in the location of an intraorbital foreign body - a case report.\",\"authors\":\"Mateusz Dworak, Kamila Stolcman-Mrugała, Zuzanna Gałuszka, Karolina Pasierb, Robert Chrzan, Jacek Składzień\",\"doi\":\"10.24425/fmc.2024.152175\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Intraorbital foreign bodies still remain an unsolved and serious diagnostic problem. Due to the complicated anatomical orbital structure, both the diagnosis and treatment of these injuries are considered to be one of the most challenging. We present a case of a metallic foreign body (a bullet) imbeded in the orbit of a 10-year-old boy. Only after performing computed tomography imaging using the metal artifacts reduction algorithm it was possible to properly localize the foreign body. The issue of intraorbital foreign bodies is interdisciplinary and requires the co-operation between many specialists, including ophthalmologists, otorhinolaryngologists and radiologists.</p>\",\"PeriodicalId\":12106,\"journal\":{\"name\":\"Folia medica Cracoviensia\",\"volume\":\"64 3\",\"pages\":\"143-153\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Folia medica Cracoviensia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/fmc.2024.152175\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Folia medica Cracoviensia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/fmc.2024.152175","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
The usefulness of computed tomography with the reduction of metal artifacts in the location of an intraorbital foreign body - a case report.
Intraorbital foreign bodies still remain an unsolved and serious diagnostic problem. Due to the complicated anatomical orbital structure, both the diagnosis and treatment of these injuries are considered to be one of the most challenging. We present a case of a metallic foreign body (a bullet) imbeded in the orbit of a 10-year-old boy. Only after performing computed tomography imaging using the metal artifacts reduction algorithm it was possible to properly localize the foreign body. The issue of intraorbital foreign bodies is interdisciplinary and requires the co-operation between many specialists, including ophthalmologists, otorhinolaryngologists and radiologists.