Haley M. Ketteler , Erick L. Johnson , Matthew McGlennen , Markus Dieser , Christine M. Foreman , Stephan Warnat
{"title":"集成微型传感器的模拟微重力生物膜反应器:推进近空间条件下的生物膜研究","authors":"Haley M. Ketteler , Erick L. Johnson , Matthew McGlennen , Markus Dieser , Christine M. Foreman , Stephan Warnat","doi":"10.1016/j.bioflm.2025.100263","DOIUrl":null,"url":null,"abstract":"<div><div>Studying biofilms in a microgravity environment currently relies on one of two scenarios, collecting planktonic aggregates in rotating wall vessels or performing experiments in the microgravity environment of space on the International Space Station. While informative techniques, both have their limitations when studying surface-attached microbial communities. A simulated microgravity biofilm reactor (SMBR) was developed to study biofilms in microgravity, coupled with the integration of microfabricated sensors for internal system monitoring. The establishment of simulated microgravity was demonstrated through computational fluid dynamic modelling revealing low fluid shear stress conditions (<1 mPa) throughout the reactor and on the wall surface. Microfabricated resistance temperature devices integrated in the reactor walls confirmed the capability for continuous sensor measurements during operation with the ability to perform traditional microbiology analyses on the sensor surface following an experiment. Microbiological analyses established that there were no significant differences in biofilm growth between sensor and wall surfaces within the reactor. With the integration of defined sampling surfaces, the SMBR allows for in-depth biofilm analysis in a repeatable and accessible manner allowing for a greater understanding of the effects of microgravity on biofilm.</div></div>","PeriodicalId":55844,"journal":{"name":"Biofilm","volume":"9 ","pages":"Article 100263"},"PeriodicalIF":4.9000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A simulated microgravity biofilm reactor with integrated microfabricated sensors: Advancing biofilm studies in near-space conditions\",\"authors\":\"Haley M. Ketteler , Erick L. Johnson , Matthew McGlennen , Markus Dieser , Christine M. Foreman , Stephan Warnat\",\"doi\":\"10.1016/j.bioflm.2025.100263\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Studying biofilms in a microgravity environment currently relies on one of two scenarios, collecting planktonic aggregates in rotating wall vessels or performing experiments in the microgravity environment of space on the International Space Station. While informative techniques, both have their limitations when studying surface-attached microbial communities. A simulated microgravity biofilm reactor (SMBR) was developed to study biofilms in microgravity, coupled with the integration of microfabricated sensors for internal system monitoring. The establishment of simulated microgravity was demonstrated through computational fluid dynamic modelling revealing low fluid shear stress conditions (<1 mPa) throughout the reactor and on the wall surface. Microfabricated resistance temperature devices integrated in the reactor walls confirmed the capability for continuous sensor measurements during operation with the ability to perform traditional microbiology analyses on the sensor surface following an experiment. Microbiological analyses established that there were no significant differences in biofilm growth between sensor and wall surfaces within the reactor. With the integration of defined sampling surfaces, the SMBR allows for in-depth biofilm analysis in a repeatable and accessible manner allowing for a greater understanding of the effects of microgravity on biofilm.</div></div>\",\"PeriodicalId\":55844,\"journal\":{\"name\":\"Biofilm\",\"volume\":\"9 \",\"pages\":\"Article 100263\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2025-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biofilm\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590207525000115\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biofilm","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590207525000115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MICROBIOLOGY","Score":null,"Total":0}
A simulated microgravity biofilm reactor with integrated microfabricated sensors: Advancing biofilm studies in near-space conditions
Studying biofilms in a microgravity environment currently relies on one of two scenarios, collecting planktonic aggregates in rotating wall vessels or performing experiments in the microgravity environment of space on the International Space Station. While informative techniques, both have their limitations when studying surface-attached microbial communities. A simulated microgravity biofilm reactor (SMBR) was developed to study biofilms in microgravity, coupled with the integration of microfabricated sensors for internal system monitoring. The establishment of simulated microgravity was demonstrated through computational fluid dynamic modelling revealing low fluid shear stress conditions (<1 mPa) throughout the reactor and on the wall surface. Microfabricated resistance temperature devices integrated in the reactor walls confirmed the capability for continuous sensor measurements during operation with the ability to perform traditional microbiology analyses on the sensor surface following an experiment. Microbiological analyses established that there were no significant differences in biofilm growth between sensor and wall surfaces within the reactor. With the integration of defined sampling surfaces, the SMBR allows for in-depth biofilm analysis in a repeatable and accessible manner allowing for a greater understanding of the effects of microgravity on biofilm.