Nina P Haag, Julius H Niehoff, Iram Shahzadi, Christoph Panknin, Marcus Wiemer, Sven Kaese, Roman Johannes Gertz, Lenhard Pennig, Ole Inuk Platte, Alexey Surov, Jan Borggrefe, Jan Robert Kroeger
{"title":"利用新型重建算法提高光子计数冠状动脉 CT 血管造影的图像质量和诊断可用性。","authors":"Nina P Haag, Julius H Niehoff, Iram Shahzadi, Christoph Panknin, Marcus Wiemer, Sven Kaese, Roman Johannes Gertz, Lenhard Pennig, Ole Inuk Platte, Alexey Surov, Jan Borggrefe, Jan Robert Kroeger","doi":"10.1007/s00330-025-11429-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Qualitative comparison of image quality and diagnostic usability of the recently introduced ZeeFree (ZF) reconstruction algorithm for photon-counting coronary CT angiography (cCTA) with Standard (SD) and TrueStack (TS) reconstruction algorithms.</p><p><strong>Methods and materials: </strong>This retrospective single-center study included 59 patients (mean age 62.5 ± 13.7, 37 males) who were referred for cCTA on a clinical photon-counting CT scanner between July and December 2023. Curved planar reformations were reconstructed for coronary arteries using ZF, SD, and TS algorithms. Three blinded radiologists individually evaluated image quality on a 5-point Likert scale (5 = excellent; median and interquartile range). Differences were evaluated using Friedman's test with pair-wise post-hoc testing. Readers were advised to assess the image quality to be diagnostic using a dichotomous yes/no question, with results being presented as percentages and significance evaluated by the Pearson Chi-Square test. Interrater reliability for image quality used Gwet's AC2 coefficient with ordinal weights, and Gwet's AC1 coefficient for diagnostic usability.</p><p><strong>Results: </strong>ZF showed superior quality (4 (2)) compared to SD (4 (2), p = 0.03) and TS (4 (1), p < 0.001) while a substantial inter-rater agreement was observed for all algorithms (0.70-0.74). Furthermore, ZF obtained the highest diagnostic usability compared to SD (82.5% vs. 77.0%, p < 0.001) and TS (75.5%, p < 0.001) while yielding an almost perfect inter-rater agreement (0.84).</p><p><strong>Conclusion: </strong>Compared to SD and TS, the novel ZF image reconstruction algorithm for photon-counting cCTA provides improved image quality and diagnostic usability, suggesting its primary use for clinical assessment.</p><p><strong>Key points: </strong>Question How well does the novel ZeeFree algorithm address motion artifacts in photon-counting coronary CT angiography? Findings ZeeFree significantly outperformed Standard and TrueStack reconstruction algorithms for image quality and diagnostic usability. Clinical relevance Enhanced image quality with ZeeFree could improve the diagnosis of coronary artery disease.</p>","PeriodicalId":12076,"journal":{"name":"European Radiology","volume":" ","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improving image quality and diagnostic usability in photon-counting coronary CT angiography using a novel reconstruction algorithm.\",\"authors\":\"Nina P Haag, Julius H Niehoff, Iram Shahzadi, Christoph Panknin, Marcus Wiemer, Sven Kaese, Roman Johannes Gertz, Lenhard Pennig, Ole Inuk Platte, Alexey Surov, Jan Borggrefe, Jan Robert Kroeger\",\"doi\":\"10.1007/s00330-025-11429-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Qualitative comparison of image quality and diagnostic usability of the recently introduced ZeeFree (ZF) reconstruction algorithm for photon-counting coronary CT angiography (cCTA) with Standard (SD) and TrueStack (TS) reconstruction algorithms.</p><p><strong>Methods and materials: </strong>This retrospective single-center study included 59 patients (mean age 62.5 ± 13.7, 37 males) who were referred for cCTA on a clinical photon-counting CT scanner between July and December 2023. Curved planar reformations were reconstructed for coronary arteries using ZF, SD, and TS algorithms. Three blinded radiologists individually evaluated image quality on a 5-point Likert scale (5 = excellent; median and interquartile range). Differences were evaluated using Friedman's test with pair-wise post-hoc testing. Readers were advised to assess the image quality to be diagnostic using a dichotomous yes/no question, with results being presented as percentages and significance evaluated by the Pearson Chi-Square test. Interrater reliability for image quality used Gwet's AC2 coefficient with ordinal weights, and Gwet's AC1 coefficient for diagnostic usability.</p><p><strong>Results: </strong>ZF showed superior quality (4 (2)) compared to SD (4 (2), p = 0.03) and TS (4 (1), p < 0.001) while a substantial inter-rater agreement was observed for all algorithms (0.70-0.74). Furthermore, ZF obtained the highest diagnostic usability compared to SD (82.5% vs. 77.0%, p < 0.001) and TS (75.5%, p < 0.001) while yielding an almost perfect inter-rater agreement (0.84).</p><p><strong>Conclusion: </strong>Compared to SD and TS, the novel ZF image reconstruction algorithm for photon-counting cCTA provides improved image quality and diagnostic usability, suggesting its primary use for clinical assessment.</p><p><strong>Key points: </strong>Question How well does the novel ZeeFree algorithm address motion artifacts in photon-counting coronary CT angiography? Findings ZeeFree significantly outperformed Standard and TrueStack reconstruction algorithms for image quality and diagnostic usability. Clinical relevance Enhanced image quality with ZeeFree could improve the diagnosis of coronary artery disease.</p>\",\"PeriodicalId\":12076,\"journal\":{\"name\":\"European Radiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-02-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00330-025-11429-z\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00330-025-11429-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Improving image quality and diagnostic usability in photon-counting coronary CT angiography using a novel reconstruction algorithm.
Purpose: Qualitative comparison of image quality and diagnostic usability of the recently introduced ZeeFree (ZF) reconstruction algorithm for photon-counting coronary CT angiography (cCTA) with Standard (SD) and TrueStack (TS) reconstruction algorithms.
Methods and materials: This retrospective single-center study included 59 patients (mean age 62.5 ± 13.7, 37 males) who were referred for cCTA on a clinical photon-counting CT scanner between July and December 2023. Curved planar reformations were reconstructed for coronary arteries using ZF, SD, and TS algorithms. Three blinded radiologists individually evaluated image quality on a 5-point Likert scale (5 = excellent; median and interquartile range). Differences were evaluated using Friedman's test with pair-wise post-hoc testing. Readers were advised to assess the image quality to be diagnostic using a dichotomous yes/no question, with results being presented as percentages and significance evaluated by the Pearson Chi-Square test. Interrater reliability for image quality used Gwet's AC2 coefficient with ordinal weights, and Gwet's AC1 coefficient for diagnostic usability.
Results: ZF showed superior quality (4 (2)) compared to SD (4 (2), p = 0.03) and TS (4 (1), p < 0.001) while a substantial inter-rater agreement was observed for all algorithms (0.70-0.74). Furthermore, ZF obtained the highest diagnostic usability compared to SD (82.5% vs. 77.0%, p < 0.001) and TS (75.5%, p < 0.001) while yielding an almost perfect inter-rater agreement (0.84).
Conclusion: Compared to SD and TS, the novel ZF image reconstruction algorithm for photon-counting cCTA provides improved image quality and diagnostic usability, suggesting its primary use for clinical assessment.
Key points: Question How well does the novel ZeeFree algorithm address motion artifacts in photon-counting coronary CT angiography? Findings ZeeFree significantly outperformed Standard and TrueStack reconstruction algorithms for image quality and diagnostic usability. Clinical relevance Enhanced image quality with ZeeFree could improve the diagnosis of coronary artery disease.
期刊介绍:
European Radiology (ER) continuously updates scientific knowledge in radiology by publication of strong original articles and state-of-the-art reviews written by leading radiologists. A well balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes ER an indispensable source for current information in this field.
This is the Journal of the European Society of Radiology, and the official journal of a number of societies.
From 2004-2008 supplements to European Radiology were published under its companion, European Radiology Supplements, ISSN 1613-3749.