{"title":"Scheimpflug-Placido地形仪(Sirius®)和前段扫描源光学相干断层扫描(ANTERİON®)设备在角膜锥形和健康眼睛角膜高阶像差中的一致性","authors":"Furkan Ozer, Metin Unlu, Kubra Erdogan, Kuddusi Erkilic","doi":"10.1007/s10792-025-03434-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the Scheimpflug-Placido Topographer (SP-T; Sirius<sup>®</sup>) and anterior-segment Swept-Source Optical Coherence Tomography (asSS-OCT; ANTERİON<sup>®</sup>) for high order corneal aberrations in healthy subjects and patients diagnosed with stage 1 and 2 keratoconus.</p><p><strong>Methods: </strong>The 125 eyes of 125 patients were included in the study and were divided into four groups based on their stage of keratoconus (KC) and the presence or absence of corneal cross-linking (CXL). The first group (KC1 group, n = 33) consisted of patients with stage 1 KC who underwent CXL, while the second group (ncKC1 group, n = 33) comprised patients with stage 1 KC who did not receive CXL. The third group (KC2 group, n = 26) included patients with stage 2 KC who underwent CXL, and the final group (control group, n = 33) consisted of healthy subjects. Root mean square (RMS) HOA (High-order aberration), horizontal trefoil (TrA), spherical aberration (SpA) and horizontal coma were compared between the SP-T and asSS-OCT to determine differences and agreement.</p><p><strong>Results: </strong>A notable difference was observed between the devices in the control group for RMS HOA, horizontal TrA, and coma (p = 0.001, p = 0.026 and p < 0.001, respectively). In the KC1 group, a proportional bias was identified with regard to horizontal coma and RMS HOA (p = 0.025 and p = 0.043). For SpA, a proportional and fixed bias was observed in both the ncKC1 and control groups.</p><p><strong>Conclusions: </strong>In the KC2 group, all parameters were in agreement, proving interchangeability between the SP-T and asSS-OCT devices. However, horizontal coma and HOA in KC1, as well as SpA in the control and ncKC1 groups, did not demonstrate this agreement. The interchangeability between devices may change according to the KC stage or CXL status.</p>","PeriodicalId":14473,"journal":{"name":"International Ophthalmology","volume":"45 1","pages":"75"},"PeriodicalIF":1.4000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Agreement between Scheimpflug-Placido topographer (Sirius<sup>®</sup>) and anterior-segment swept-source optical coherence tomography (ANTERİON<sup>®</sup>) devices for corneal high order aberrations in keratoconic and healthy eyes.\",\"authors\":\"Furkan Ozer, Metin Unlu, Kubra Erdogan, Kuddusi Erkilic\",\"doi\":\"10.1007/s10792-025-03434-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare the Scheimpflug-Placido Topographer (SP-T; Sirius<sup>®</sup>) and anterior-segment Swept-Source Optical Coherence Tomography (asSS-OCT; ANTERİON<sup>®</sup>) for high order corneal aberrations in healthy subjects and patients diagnosed with stage 1 and 2 keratoconus.</p><p><strong>Methods: </strong>The 125 eyes of 125 patients were included in the study and were divided into four groups based on their stage of keratoconus (KC) and the presence or absence of corneal cross-linking (CXL). The first group (KC1 group, n = 33) consisted of patients with stage 1 KC who underwent CXL, while the second group (ncKC1 group, n = 33) comprised patients with stage 1 KC who did not receive CXL. The third group (KC2 group, n = 26) included patients with stage 2 KC who underwent CXL, and the final group (control group, n = 33) consisted of healthy subjects. Root mean square (RMS) HOA (High-order aberration), horizontal trefoil (TrA), spherical aberration (SpA) and horizontal coma were compared between the SP-T and asSS-OCT to determine differences and agreement.</p><p><strong>Results: </strong>A notable difference was observed between the devices in the control group for RMS HOA, horizontal TrA, and coma (p = 0.001, p = 0.026 and p < 0.001, respectively). In the KC1 group, a proportional bias was identified with regard to horizontal coma and RMS HOA (p = 0.025 and p = 0.043). For SpA, a proportional and fixed bias was observed in both the ncKC1 and control groups.</p><p><strong>Conclusions: </strong>In the KC2 group, all parameters were in agreement, proving interchangeability between the SP-T and asSS-OCT devices. However, horizontal coma and HOA in KC1, as well as SpA in the control and ncKC1 groups, did not demonstrate this agreement. The interchangeability between devices may change according to the KC stage or CXL status.</p>\",\"PeriodicalId\":14473,\"journal\":{\"name\":\"International Ophthalmology\",\"volume\":\"45 1\",\"pages\":\"75\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-02-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10792-025-03434-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10792-025-03434-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较Scheimpflug-Placido Topographer (SP-T);Sirius®)和前段扫描源光学相干层析成像(asSS-OCT;ANTERİON®)用于健康受试者和诊断为1期和2期圆锥角膜的患者的高阶角膜畸变。方法:选取125例患者125只眼,根据圆锥角膜(KC)分期及有无角膜交联(CXL)分为4组。第一组(KC1组,n = 33)由接受CXL的1期KC患者组成,而第二组(ncKC1组,n = 33)由未接受CXL的1期KC患者组成。第三组(KC2组,n = 26)为接受CXL治疗的2期KC患者,最后一组(对照组,n = 33)为健康受试者。比较SP-T和asSS-OCT的高阶像差(HOA)、水平三叶像差(TrA)、球差(SpA)和水平彗差的均方根(RMS)差异和一致性。结果:对照组设备在RMS HOA、水平TrA和昏迷方面存在显著差异(p = 0.001、p = 0.026和p)。结论:在KC2组,所有参数一致,证明SP-T和asSS-OCT设备之间具有互换性。然而,KC1组的水平昏迷和HOA,以及对照组和ncKC1组的SpA,并没有显示出这种一致。设备之间的互换性可能根据KC阶段或CXL状态而变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Agreement between Scheimpflug-Placido topographer (Sirius®) and anterior-segment swept-source optical coherence tomography (ANTERİON®) devices for corneal high order aberrations in keratoconic and healthy eyes.

Purpose: To compare the Scheimpflug-Placido Topographer (SP-T; Sirius®) and anterior-segment Swept-Source Optical Coherence Tomography (asSS-OCT; ANTERİON®) for high order corneal aberrations in healthy subjects and patients diagnosed with stage 1 and 2 keratoconus.

Methods: The 125 eyes of 125 patients were included in the study and were divided into four groups based on their stage of keratoconus (KC) and the presence or absence of corneal cross-linking (CXL). The first group (KC1 group, n = 33) consisted of patients with stage 1 KC who underwent CXL, while the second group (ncKC1 group, n = 33) comprised patients with stage 1 KC who did not receive CXL. The third group (KC2 group, n = 26) included patients with stage 2 KC who underwent CXL, and the final group (control group, n = 33) consisted of healthy subjects. Root mean square (RMS) HOA (High-order aberration), horizontal trefoil (TrA), spherical aberration (SpA) and horizontal coma were compared between the SP-T and asSS-OCT to determine differences and agreement.

Results: A notable difference was observed between the devices in the control group for RMS HOA, horizontal TrA, and coma (p = 0.001, p = 0.026 and p < 0.001, respectively). In the KC1 group, a proportional bias was identified with regard to horizontal coma and RMS HOA (p = 0.025 and p = 0.043). For SpA, a proportional and fixed bias was observed in both the ncKC1 and control groups.

Conclusions: In the KC2 group, all parameters were in agreement, proving interchangeability between the SP-T and asSS-OCT devices. However, horizontal coma and HOA in KC1, as well as SpA in the control and ncKC1 groups, did not demonstrate this agreement. The interchangeability between devices may change according to the KC stage or CXL status.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
451
期刊介绍: International Ophthalmology provides the clinician with articles on all the relevant subspecialties of ophthalmology, with a broad international scope. The emphasis is on presentation of the latest clinical research in the field. In addition, the journal includes regular sections devoted to new developments in technologies, products, and techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信