评价功能数据一致性的非标度指标

IF 1.3 3区 生物学 Q4 MATHEMATICAL & COMPUTATIONAL BIOLOGY
Kaeum Choi, Jeong Hoon Jang
{"title":"评价功能数据一致性的非标度指标","authors":"Kaeum Choi,&nbsp;Jeong Hoon Jang","doi":"10.1002/bimj.70039","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>A decision to adopt a new medical device requires a rigorous assessment of the reliability and reproducibility of its clinical measurements. In this paper, with the goal of establishing the validity and acceptability of modern high-tech medical devices that generate functional data, we focus on the problem of assessing agreement of multiple functional data that are measured on the same subjects by different methods/technologies/raters. Specifically, we introduce a series of unscaled indices, total deviation index (TDI) and coverage probability (CP), that themselves are functions of time and can delineate the trends of intramethod, intermethod, and total (intra+inter) agreement of functional data across time in terms of the original measurement scale. We also develop scalar-valued TDI and CP indices that summarize the degree of agreement over the entire domain based on the weighted average idea. We advocate an experimental design under which each of the two methods generates replicated functional data measurements for each subject, and express each index using a mean function and variance components of a bivariate multilevel functional linear mixed effects model. Such a formulation allows us to smoothly estimate the indices based on our bivariate multilevel functional principal component analysis approach that only requires eigenanalyses of univariate covariance functions for better efficiency and scalability. Comprehensive simulation studies are conducted to examine the finite-sample properties of the estimators. The proposed method is applied to assess the reliability and reproducibility of renogram curves generated by diuresis renography, a high-tech medical imaging device widely used to detect kidney obstruction.</p></div>","PeriodicalId":55360,"journal":{"name":"Biometrical Journal","volume":"67 1","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Unscaled Indices for Assessing Agreement of Functional Data\",\"authors\":\"Kaeum Choi,&nbsp;Jeong Hoon Jang\",\"doi\":\"10.1002/bimj.70039\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>A decision to adopt a new medical device requires a rigorous assessment of the reliability and reproducibility of its clinical measurements. In this paper, with the goal of establishing the validity and acceptability of modern high-tech medical devices that generate functional data, we focus on the problem of assessing agreement of multiple functional data that are measured on the same subjects by different methods/technologies/raters. Specifically, we introduce a series of unscaled indices, total deviation index (TDI) and coverage probability (CP), that themselves are functions of time and can delineate the trends of intramethod, intermethod, and total (intra+inter) agreement of functional data across time in terms of the original measurement scale. We also develop scalar-valued TDI and CP indices that summarize the degree of agreement over the entire domain based on the weighted average idea. We advocate an experimental design under which each of the two methods generates replicated functional data measurements for each subject, and express each index using a mean function and variance components of a bivariate multilevel functional linear mixed effects model. Such a formulation allows us to smoothly estimate the indices based on our bivariate multilevel functional principal component analysis approach that only requires eigenanalyses of univariate covariance functions for better efficiency and scalability. Comprehensive simulation studies are conducted to examine the finite-sample properties of the estimators. The proposed method is applied to assess the reliability and reproducibility of renogram curves generated by diuresis renography, a high-tech medical imaging device widely used to detect kidney obstruction.</p></div>\",\"PeriodicalId\":55360,\"journal\":{\"name\":\"Biometrical Journal\",\"volume\":\"67 1\",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-02-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biometrical Journal\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bimj.70039\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATHEMATICAL & COMPUTATIONAL BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biometrical Journal","FirstCategoryId":"99","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bimj.70039","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATHEMATICAL & COMPUTATIONAL BIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

决定采用一种新的医疗装置需要对其临床测量的可靠性和可重复性进行严格评估。本文以建立现代高科技医疗器械产生功能数据的有效性和可接受性为目标,重点研究了用不同方法/技术/评分者在同一受试者上测量的多个功能数据的一致性评估问题。具体而言,我们引入了一系列未标度指标,即总偏差指数(TDI)和覆盖概率(CP),它们本身是时间的函数,可以描述方法内、方法间和功能数据在原始测量尺度上的总(内+间)一致性随时间的变化趋势。我们还开发了基于加权平均思想的标量值TDI和CP指标,它们总结了整个领域的一致性程度。我们提倡一种实验设计,在这种设计下,两种方法中的每一种都为每个受试者产生重复的功能数据测量,并使用二元多层功能线性混合效应模型的均值函数和方差成分来表达每个指标。这样的公式使我们能够基于二元多水平功能主成分分析方法平滑地估计指标,该方法只需要单变量协方差函数的特征分析,以获得更好的效率和可扩展性。进行了全面的仿真研究,以检验估计器的有限样本性质。该方法用于评估利尿肾造影生成的肾图曲线的可靠性和再现性,利尿肾造影是一种广泛用于检测肾梗阻的高科技医学成像设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Unscaled Indices for Assessing Agreement of Functional Data

A decision to adopt a new medical device requires a rigorous assessment of the reliability and reproducibility of its clinical measurements. In this paper, with the goal of establishing the validity and acceptability of modern high-tech medical devices that generate functional data, we focus on the problem of assessing agreement of multiple functional data that are measured on the same subjects by different methods/technologies/raters. Specifically, we introduce a series of unscaled indices, total deviation index (TDI) and coverage probability (CP), that themselves are functions of time and can delineate the trends of intramethod, intermethod, and total (intra+inter) agreement of functional data across time in terms of the original measurement scale. We also develop scalar-valued TDI and CP indices that summarize the degree of agreement over the entire domain based on the weighted average idea. We advocate an experimental design under which each of the two methods generates replicated functional data measurements for each subject, and express each index using a mean function and variance components of a bivariate multilevel functional linear mixed effects model. Such a formulation allows us to smoothly estimate the indices based on our bivariate multilevel functional principal component analysis approach that only requires eigenanalyses of univariate covariance functions for better efficiency and scalability. Comprehensive simulation studies are conducted to examine the finite-sample properties of the estimators. The proposed method is applied to assess the reliability and reproducibility of renogram curves generated by diuresis renography, a high-tech medical imaging device widely used to detect kidney obstruction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biometrical Journal
Biometrical Journal 生物-数学与计算生物学
CiteScore
3.20
自引率
5.90%
发文量
119
审稿时长
6-12 weeks
期刊介绍: Biometrical Journal publishes papers on statistical methods and their applications in life sciences including medicine, environmental sciences and agriculture. Methodological developments should be motivated by an interesting and relevant problem from these areas. Ideally the manuscript should include a description of the problem and a section detailing the application of the new methodology to the problem. Case studies, review articles and letters to the editors are also welcome. Papers containing only extensive mathematical theory are not suitable for publication in Biometrical Journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信