一种基于人工智能的工具的验证——将角膜扩张的客观风险筛查整合到前角中,用于检测角膜扩张/扩张风险。

IF 0.5 Q4 OPHTHALMOLOGY
Middle East African Journal of Ophthalmology Pub Date : 2024-12-02 eCollection Date: 2023-10-01 DOI:10.4103/meajo.meajo_215_22
Ramya S Raju, C V Gopal Raju
{"title":"一种基于人工智能的工具的验证——将角膜扩张的客观风险筛查整合到前角中,用于检测角膜扩张/扩张风险。","authors":"Ramya S Raju, C V Gopal Raju","doi":"10.4103/meajo.meajo_215_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to validate the artificial intelligence-based Screening Corneal Objective Risk of Ectasia (SCORE) for the detection of corneal ectasia/risk of ectasia and to find the mean SCORE value in normal eyes.</p><p><strong>Methods: </strong>This prospective observational study included 320 eyes of 160 patients undergoing screening for refractive surgery and keratoconus. All were subjected to Anterion (Heidelberg, Germany) corneal tomography. The maps were read by trained cornea specialists masked with respect to system-generated SCORE. The SCORE values were retrieved by another masked observer. The SCORE was labeled true positive if the eye was tomographically positive for ectasia/ risk of ectasia with or without clinical evidence of ectasia (i.e., clinician's diagnosis as ectasia/ risk of ectasia) and SCORE was >/=0. The SCORE test was labeled as true negative if all the maps were normal and SCORE was <0. A false-positive test was where the eye was normal but SCORE was ≥0. A false-negative test was one tomographically there was definite evidence of ectasia/ risk; with or without clinical evidence of ectasia (i.e.,clinician's diagnosis as ectasia/ at risk of ectasia) but SCORE was <0. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated.</p><p><strong>Results: </strong>The mean SCORE in normal eyes was -0.7 ± 0.6. Sensitivity was 83.3% and specificity was 80%. PPV and NPV were 46% and 96% respectively. In the keratoconus subgroup, specificity and PPV were 100%; sensitivity was 79% and NPV was 76.3%.</p><p><strong>Conclusion: </strong>SCORE in Anterion has moderate sensitivity and specificity for detection of ectasia/risk of ectasia. It performs best in the detection of corneal ectasia. It needs to be interpreted with caution.</p>","PeriodicalId":18740,"journal":{"name":"Middle East African Journal of Ophthalmology","volume":"30 4","pages":"257-265"},"PeriodicalIF":0.5000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11823529/pdf/","citationCount":"0","resultStr":"{\"title\":\"Validation of an Artificial Intelligence-based Tool - The Screening Corneal Objective Risk of Ectasia Integrated into Anterion for Detection of Corneal Ectasia/Risk of Ectasia.\",\"authors\":\"Ramya S Raju, C V Gopal Raju\",\"doi\":\"10.4103/meajo.meajo_215_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this study was to validate the artificial intelligence-based Screening Corneal Objective Risk of Ectasia (SCORE) for the detection of corneal ectasia/risk of ectasia and to find the mean SCORE value in normal eyes.</p><p><strong>Methods: </strong>This prospective observational study included 320 eyes of 160 patients undergoing screening for refractive surgery and keratoconus. All were subjected to Anterion (Heidelberg, Germany) corneal tomography. The maps were read by trained cornea specialists masked with respect to system-generated SCORE. The SCORE values were retrieved by another masked observer. The SCORE was labeled true positive if the eye was tomographically positive for ectasia/ risk of ectasia with or without clinical evidence of ectasia (i.e., clinician's diagnosis as ectasia/ risk of ectasia) and SCORE was >/=0. The SCORE test was labeled as true negative if all the maps were normal and SCORE was <0. A false-positive test was where the eye was normal but SCORE was ≥0. A false-negative test was one tomographically there was definite evidence of ectasia/ risk; with or without clinical evidence of ectasia (i.e.,clinician's diagnosis as ectasia/ at risk of ectasia) but SCORE was <0. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated.</p><p><strong>Results: </strong>The mean SCORE in normal eyes was -0.7 ± 0.6. Sensitivity was 83.3% and specificity was 80%. PPV and NPV were 46% and 96% respectively. In the keratoconus subgroup, specificity and PPV were 100%; sensitivity was 79% and NPV was 76.3%.</p><p><strong>Conclusion: </strong>SCORE in Anterion has moderate sensitivity and specificity for detection of ectasia/risk of ectasia. It performs best in the detection of corneal ectasia. It needs to be interpreted with caution.</p>\",\"PeriodicalId\":18740,\"journal\":{\"name\":\"Middle East African Journal of Ophthalmology\",\"volume\":\"30 4\",\"pages\":\"257-265\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2024-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11823529/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Middle East African Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/meajo.meajo_215_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Middle East African Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/meajo.meajo_215_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是验证基于人工智能的筛查角膜客观扩张风险(SCORE)检测角膜扩张/扩张风险,并找到正常眼睛的平均SCORE值。方法:本前瞻性观察研究纳入160例接受屈光手术和圆锥角膜筛查的320只眼。所有患者均行Anterion (Heidelberg, Germany)角膜断层扫描。这些地图由训练有素的角膜专家阅读,并对系统生成的SCORE进行掩盖。SCORE值由另一个被屏蔽的观察者检索。如果有或没有临床证据(即临床医生诊断为扩张/扩张风险),眼睛的断层扫描呈扩张/扩张风险阳性,SCORE标记为真阳性,SCORE为>/=0。结果:正常眼的平均SCORE为-0.7±0.6。敏感性为83.3%,特异性为80%。PPV和NPV分别为46%和96%。圆锥角膜亚组特异性和PPV均为100%;敏感性为79%,NPV为76.3%。结论:SCORE在检测肛肠扩张/扩张风险方面具有中等的敏感性和特异性。它对角膜扩张的检测效果最好。这需要谨慎解读。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of an Artificial Intelligence-based Tool - The Screening Corneal Objective Risk of Ectasia Integrated into Anterion for Detection of Corneal Ectasia/Risk of Ectasia.

Purpose: The purpose of this study was to validate the artificial intelligence-based Screening Corneal Objective Risk of Ectasia (SCORE) for the detection of corneal ectasia/risk of ectasia and to find the mean SCORE value in normal eyes.

Methods: This prospective observational study included 320 eyes of 160 patients undergoing screening for refractive surgery and keratoconus. All were subjected to Anterion (Heidelberg, Germany) corneal tomography. The maps were read by trained cornea specialists masked with respect to system-generated SCORE. The SCORE values were retrieved by another masked observer. The SCORE was labeled true positive if the eye was tomographically positive for ectasia/ risk of ectasia with or without clinical evidence of ectasia (i.e., clinician's diagnosis as ectasia/ risk of ectasia) and SCORE was >/=0. The SCORE test was labeled as true negative if all the maps were normal and SCORE was <0. A false-positive test was where the eye was normal but SCORE was ≥0. A false-negative test was one tomographically there was definite evidence of ectasia/ risk; with or without clinical evidence of ectasia (i.e.,clinician's diagnosis as ectasia/ at risk of ectasia) but SCORE was <0. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated.

Results: The mean SCORE in normal eyes was -0.7 ± 0.6. Sensitivity was 83.3% and specificity was 80%. PPV and NPV were 46% and 96% respectively. In the keratoconus subgroup, specificity and PPV were 100%; sensitivity was 79% and NPV was 76.3%.

Conclusion: SCORE in Anterion has moderate sensitivity and specificity for detection of ectasia/risk of ectasia. It performs best in the detection of corneal ectasia. It needs to be interpreted with caution.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
1
期刊介绍: The Middle East African Journal of Ophthalmology (MEAJO), published four times per year in print and online, is an official journal of the Middle East African Council of Ophthalmology (MEACO). It is an international, peer-reviewed journal whose mission includes publication of original research of interest to ophthalmologists in the Middle East and Africa, and to provide readers with high quality educational review articles from world-renown experts. MEAJO, previously known as Middle East Journal of Ophthalmology (MEJO) was founded by Dr Akef El Maghraby in 1993.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信