Ali Khanafer, Pablo Albiña-Palmarola, Philipp von Gottberg, Kamran Hajiyev, Sebastian J Müller, Jose E Cohen, Hans Henkes
{"title":"亲水聚合物包被分流器治疗未破裂颅内动脉瘤后临床无症状微梗死发生率及危险因素","authors":"Ali Khanafer, Pablo Albiña-Palmarola, Philipp von Gottberg, Kamran Hajiyev, Sebastian J Müller, Jose E Cohen, Hans Henkes","doi":"10.1007/s00062-025-01497-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Although flow diverters (FDs) revolutionized the treatment of unruptured intracranial aneurysms (UIAs), clinically silent microinfarcts (SMs) are consistently detected in postprocedural diffusion-weighted imaging (DWI), and their clinical consequences remain unknown. This study examined the incidence of, and factors associated with, SM development after the use of two surface-modified FDs: the p48MW-HPC and p64MW-HPC.</p><p><strong>Methods: </strong>A non-concurrent cohort study was conducted in 404 consecutive patients with UIAs treated with these two FDs between January 2020 and July 2023. The primary endpoint was the number of asymptomatic DWI lesions within 72 h after the procedure.</p><p><strong>Results: </strong>SMs were detected in 58.2% of the cases, and ≥ 20 lesions were identified in 7.2% of cases. Multivariate analysis revealed that the use of two specific types of microcatheters-Prowler Select Plus (P < 0.001; IRR, 3.2) and RapidTransit (P = 0.001; IRR, 2.2)-and difficulty in microcatheter navigation to the target vessel (P = 0.039; IRR, 1.8) were significantly associated with greater numbers of lesions. After exclusion of outlier cases, these devices remained associated with a significant 2‑ to 3‑fold increase in SMs. Diabetes was associated with fewer SMs (P = 0.024; IRR, 0.5), although this association disappeared after exclusion of outlier cases.</p><p><strong>Conclusion: </strong>The postprocedural incidence of SMs associated with hydrophilic polymer-coated FDs was similar to that previously reported. Interestingly, the main factor contributing to this phenomenon was the use of certain microcatheters. Careful device selection is crucial, and further research is needed to improve the safety of neurovascular interventions.</p>","PeriodicalId":49298,"journal":{"name":"Clinical Neuroradiology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinically Silent Microinfarct Incidence and Risk Factors After Treatment of Unruptured Intracranial Aneurysms with Hydrophilic Polymer-Coated Flow Diverters.\",\"authors\":\"Ali Khanafer, Pablo Albiña-Palmarola, Philipp von Gottberg, Kamran Hajiyev, Sebastian J Müller, Jose E Cohen, Hans Henkes\",\"doi\":\"10.1007/s00062-025-01497-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Although flow diverters (FDs) revolutionized the treatment of unruptured intracranial aneurysms (UIAs), clinically silent microinfarcts (SMs) are consistently detected in postprocedural diffusion-weighted imaging (DWI), and their clinical consequences remain unknown. This study examined the incidence of, and factors associated with, SM development after the use of two surface-modified FDs: the p48MW-HPC and p64MW-HPC.</p><p><strong>Methods: </strong>A non-concurrent cohort study was conducted in 404 consecutive patients with UIAs treated with these two FDs between January 2020 and July 2023. The primary endpoint was the number of asymptomatic DWI lesions within 72 h after the procedure.</p><p><strong>Results: </strong>SMs were detected in 58.2% of the cases, and ≥ 20 lesions were identified in 7.2% of cases. Multivariate analysis revealed that the use of two specific types of microcatheters-Prowler Select Plus (P < 0.001; IRR, 3.2) and RapidTransit (P = 0.001; IRR, 2.2)-and difficulty in microcatheter navigation to the target vessel (P = 0.039; IRR, 1.8) were significantly associated with greater numbers of lesions. After exclusion of outlier cases, these devices remained associated with a significant 2‑ to 3‑fold increase in SMs. Diabetes was associated with fewer SMs (P = 0.024; IRR, 0.5), although this association disappeared after exclusion of outlier cases.</p><p><strong>Conclusion: </strong>The postprocedural incidence of SMs associated with hydrophilic polymer-coated FDs was similar to that previously reported. Interestingly, the main factor contributing to this phenomenon was the use of certain microcatheters. Careful device selection is crucial, and further research is needed to improve the safety of neurovascular interventions.</p>\",\"PeriodicalId\":49298,\"journal\":{\"name\":\"Clinical Neuroradiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-02-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00062-025-01497-5\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00062-025-01497-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的:尽管血流分流器(fd)彻底改变了未破裂颅内动脉瘤(UIAs)的治疗方法,但术后弥散加权成像(DWI)经常检测到临床无症状的微梗死(SMs),其临床后果尚不清楚。本研究考察了使用两种表面改性fd (p48MW-HPC和p64MW-HPC)后SM发生的发生率及其相关因素。方法:在2020年1月至2023年7月期间,对404例连续接受这两种fd治疗的UIAs患者进行了一项非并发队列研究。主要终点是术后72小时内无症状DWI病变的数量 h。结果:58.2%的病例检出SMs, 7.2%的病例检出≥ 20个病变。多变量分析显示,两种特定类型的微导管的使用- prowler Select Plus (P )结论:与亲水性聚合物包被fd相关的术后SMs发生率与先前报道相似。有趣的是,造成这种现象的主要因素是某些微导管的使用。谨慎的设备选择是至关重要的,需要进一步的研究来提高神经血管干预的安全性。
Clinically Silent Microinfarct Incidence and Risk Factors After Treatment of Unruptured Intracranial Aneurysms with Hydrophilic Polymer-Coated Flow Diverters.
Purpose: Although flow diverters (FDs) revolutionized the treatment of unruptured intracranial aneurysms (UIAs), clinically silent microinfarcts (SMs) are consistently detected in postprocedural diffusion-weighted imaging (DWI), and their clinical consequences remain unknown. This study examined the incidence of, and factors associated with, SM development after the use of two surface-modified FDs: the p48MW-HPC and p64MW-HPC.
Methods: A non-concurrent cohort study was conducted in 404 consecutive patients with UIAs treated with these two FDs between January 2020 and July 2023. The primary endpoint was the number of asymptomatic DWI lesions within 72 h after the procedure.
Results: SMs were detected in 58.2% of the cases, and ≥ 20 lesions were identified in 7.2% of cases. Multivariate analysis revealed that the use of two specific types of microcatheters-Prowler Select Plus (P < 0.001; IRR, 3.2) and RapidTransit (P = 0.001; IRR, 2.2)-and difficulty in microcatheter navigation to the target vessel (P = 0.039; IRR, 1.8) were significantly associated with greater numbers of lesions. After exclusion of outlier cases, these devices remained associated with a significant 2‑ to 3‑fold increase in SMs. Diabetes was associated with fewer SMs (P = 0.024; IRR, 0.5), although this association disappeared after exclusion of outlier cases.
Conclusion: The postprocedural incidence of SMs associated with hydrophilic polymer-coated FDs was similar to that previously reported. Interestingly, the main factor contributing to this phenomenon was the use of certain microcatheters. Careful device selection is crucial, and further research is needed to improve the safety of neurovascular interventions.
期刊介绍:
Clinical Neuroradiology provides current information, original contributions, and reviews in the field of neuroradiology. An interdisciplinary approach is accomplished by diagnostic and therapeutic contributions related to associated subjects.
The international coverage and relevance of the journal is underlined by its being the official journal of the German, Swiss, and Austrian Societies of Neuroradiology.