他克莫司、西罗莫司和环孢素A治疗药物超快速监测方法。

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
Analytical and Bioanalytical Chemistry Pub Date : 2025-04-01 Epub Date: 2025-02-14 DOI:10.1007/s00216-025-05773-8
Zhi-Hua Lv, Xin Li, Rui Peng, Shao-Ting Wang
{"title":"他克莫司、西罗莫司和环孢素A治疗药物超快速监测方法。","authors":"Zhi-Hua Lv, Xin Li, Rui Peng, Shao-Ting Wang","doi":"10.1007/s00216-025-05773-8","DOIUrl":null,"url":null,"abstract":"<p><p>Therapeutic drug monitoring for immunosuppressants is a widely conducted global practice. Traditionally, the pretreatment of whole blood involves the use of metal ions combined with organic solvents. However, this method requires multiple reagent additions, repeated opening, closing, and vortexing of vials, and it also leads to heavy metal pollution. Given the typically large sample volumes, optimizing this process is crucial for increasing throughput, reducing the workload of clinical staff, and lowering costs. We discovered that treating whole blood with a 60 to 75% acetonitrile (ACN) solution effectively releases tacrolimus, sirolimus, and cyclosporine A while simultaneously precipitating protein. This allowed us to significantly simplify the pretreatment process to just adding 65% ACN solution containing internal standards, manually shaking for 20 s, and centrifuging for 2 min. The resulted supernatant can then be directly analyzed by mass spectrometry. Method validation demonstrated that the new approach can accurately quantify tacrolimus in the range of 0.64 to 37.5 ng/ml, cyclosporine A at 12 to 976 ng/ml, and sirolimus at 0.99 to 43.4 ng/ml. A comparison of paired samples showed the new method to be perfectly consistent with the classical method, with 293 out of 300 results deviating by no more than ± 20%. This study has greatly simplified the workflow, increased throughput, and resolved environmental concerns for therapeutic drug monitoring of immunosuppressants, including tacrolimus, sirolimus, and cyclosporine A, in whole blood samples. The proposed method is a viable replacement for existing protocols and deserves to be adopted in all clinical laboratories with relevant practical needs globally.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":" ","pages":"1915-1925"},"PeriodicalIF":3.8000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An ultra-fast method for therapeutic drug monitoring of tacrolimus, sirolimus and cyclosporine A.\",\"authors\":\"Zhi-Hua Lv, Xin Li, Rui Peng, Shao-Ting Wang\",\"doi\":\"10.1007/s00216-025-05773-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Therapeutic drug monitoring for immunosuppressants is a widely conducted global practice. Traditionally, the pretreatment of whole blood involves the use of metal ions combined with organic solvents. However, this method requires multiple reagent additions, repeated opening, closing, and vortexing of vials, and it also leads to heavy metal pollution. Given the typically large sample volumes, optimizing this process is crucial for increasing throughput, reducing the workload of clinical staff, and lowering costs. We discovered that treating whole blood with a 60 to 75% acetonitrile (ACN) solution effectively releases tacrolimus, sirolimus, and cyclosporine A while simultaneously precipitating protein. This allowed us to significantly simplify the pretreatment process to just adding 65% ACN solution containing internal standards, manually shaking for 20 s, and centrifuging for 2 min. The resulted supernatant can then be directly analyzed by mass spectrometry. Method validation demonstrated that the new approach can accurately quantify tacrolimus in the range of 0.64 to 37.5 ng/ml, cyclosporine A at 12 to 976 ng/ml, and sirolimus at 0.99 to 43.4 ng/ml. A comparison of paired samples showed the new method to be perfectly consistent with the classical method, with 293 out of 300 results deviating by no more than ± 20%. This study has greatly simplified the workflow, increased throughput, and resolved environmental concerns for therapeutic drug monitoring of immunosuppressants, including tacrolimus, sirolimus, and cyclosporine A, in whole blood samples. The proposed method is a viable replacement for existing protocols and deserves to be adopted in all clinical laboratories with relevant practical needs globally.</p>\",\"PeriodicalId\":462,\"journal\":{\"name\":\"Analytical and Bioanalytical Chemistry\",\"volume\":\" \",\"pages\":\"1915-1925\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical and Bioanalytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1007/s00216-025-05773-8\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-025-05773-8","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

免疫抑制剂的治疗药物监测是一项广泛进行的全球实践。传统上,全血预处理涉及使用金属离子与有机溶剂结合。但该方法需要多次添加试剂,反复开瓶、关瓶、旋瓶,还会导致重金属污染。鉴于通常样本量很大,优化这一过程对于提高吞吐量、减少临床工作人员的工作量和降低成本至关重要。我们发现用60%到75%的乙腈(ACN)溶液处理全血可以有效地释放他克莫司、西罗莫司和环孢素a,同时沉淀蛋白质。这使我们大大简化了预处理过程,只需加入含有内标的65% ACN溶液,手动摇晃20秒,离心2分钟。得到的上清可以直接通过质谱分析。方法验证表明,新方法可准确定量0.64 ~ 37.5 ng/ml的他克莫司、12 ~ 976 ng/ml的环孢素A和0.99 ~ 43.4 ng/ml的西罗莫司。配对样本的比较表明,新方法与经典方法完全一致,300个结果中有293个结果偏差不超过±20%。本研究极大地简化了工作流程,提高了吞吐量,并解决了全血样本中免疫抑制剂(包括他克莫司、西罗莫司和环孢素A)治疗药物监测的环境问题。所提出的方法是现有方案的可行替代方案,值得在全球所有具有相关实际需求的临床实验室采用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An ultra-fast method for therapeutic drug monitoring of tacrolimus, sirolimus and cyclosporine A.

Therapeutic drug monitoring for immunosuppressants is a widely conducted global practice. Traditionally, the pretreatment of whole blood involves the use of metal ions combined with organic solvents. However, this method requires multiple reagent additions, repeated opening, closing, and vortexing of vials, and it also leads to heavy metal pollution. Given the typically large sample volumes, optimizing this process is crucial for increasing throughput, reducing the workload of clinical staff, and lowering costs. We discovered that treating whole blood with a 60 to 75% acetonitrile (ACN) solution effectively releases tacrolimus, sirolimus, and cyclosporine A while simultaneously precipitating protein. This allowed us to significantly simplify the pretreatment process to just adding 65% ACN solution containing internal standards, manually shaking for 20 s, and centrifuging for 2 min. The resulted supernatant can then be directly analyzed by mass spectrometry. Method validation demonstrated that the new approach can accurately quantify tacrolimus in the range of 0.64 to 37.5 ng/ml, cyclosporine A at 12 to 976 ng/ml, and sirolimus at 0.99 to 43.4 ng/ml. A comparison of paired samples showed the new method to be perfectly consistent with the classical method, with 293 out of 300 results deviating by no more than ± 20%. This study has greatly simplified the workflow, increased throughput, and resolved environmental concerns for therapeutic drug monitoring of immunosuppressants, including tacrolimus, sirolimus, and cyclosporine A, in whole blood samples. The proposed method is a viable replacement for existing protocols and deserves to be adopted in all clinical laboratories with relevant practical needs globally.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
638
审稿时长
2.1 months
期刊介绍: Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信