常规和高级神经影像学在0.55-T MRI:机遇和挑战。

IF 5.2 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Radiographics Pub Date : 2025-03-01 DOI:10.1148/rg.240076
Lauren J Kelsey, Nicole Seiberlich, Joel Morehouse, Jacob Richardson, Ashok Srinivasan, Jayapalli Bapuraj, John Kim, Vikas Gulani, Shruti Mishra
{"title":"常规和高级神经影像学在0.55-T MRI:机遇和挑战。","authors":"Lauren J Kelsey, Nicole Seiberlich, Joel Morehouse, Jacob Richardson, Ashok Srinivasan, Jayapalli Bapuraj, John Kim, Vikas Gulani, Shruti Mishra","doi":"10.1148/rg.240076","DOIUrl":null,"url":null,"abstract":"<p><p>MRI for diagnosis and assessment of neurologic conditions is most commonly performed on 1.5- and 3.0-T systems. Recently, motivation to increase accessibility to MRI, coupled with advances in software and hardware, has sparked renewed interest in MRI systems with magnetic field strengths ranging from 0.064 T to 1.0 T. The authors describe the protocols and indications for neuroradiologic imaging performed on a modern whole-body, mid-field-strength 0.55-T MRI system. The overall image quality of routine clinical brain and spinal imaging at 0.55 T is lower than that at 1.5 T but still diagnostic for many routine indications. The intrinsic benefits of using a lower main magnetic field strength may be leveraged for imaging intracranial and spinal hardware due to diminished susceptibility artifacts and pose new opportunities for increased MRI safety. In addition, the imaging of structures that are near bone, such as the internal auditory canal, may represent an opportunity for additional use of MRI with lower magnetic field strengths due to reduced magnetic susceptibility differences and greater field homogeneity. However, lower main magnetic field strength limits the use of frequency-selective fat saturation and introduces challenges for Dixon-based fat suppression. The limitations of one specific 0.55-T system include acceleration artifacts and insufficient signal intensity of dynamic contrast-enhanced susceptibility-weighted perfusion imaging, which precluded the evaluation of multiple sclerosis and primary brain tumors. Investigations of ongoing technical developments of 0.55-T MRI include exploring sequence structures that are particularly advantageous at lower field strengths, such as those in balanced steady-state free-precession and single-shot fast spin-echo MRI, which are being used in functional and fetal MRI. Deep learning algorithms are also being used to improve image quality while maintaining or reducing imaging times. <sup>©</sup>RSNA, 2025 Supplemental material is available for this article. See the invited commentary by Pai and Jabehdar Maralani in this issue.</p>","PeriodicalId":54512,"journal":{"name":"Radiographics","volume":"45 3","pages":"e240076"},"PeriodicalIF":5.2000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Routine and Advanced Neurologic Imaging at 0.55-T MRI: Opportunities and Challenges.\",\"authors\":\"Lauren J Kelsey, Nicole Seiberlich, Joel Morehouse, Jacob Richardson, Ashok Srinivasan, Jayapalli Bapuraj, John Kim, Vikas Gulani, Shruti Mishra\",\"doi\":\"10.1148/rg.240076\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>MRI for diagnosis and assessment of neurologic conditions is most commonly performed on 1.5- and 3.0-T systems. Recently, motivation to increase accessibility to MRI, coupled with advances in software and hardware, has sparked renewed interest in MRI systems with magnetic field strengths ranging from 0.064 T to 1.0 T. The authors describe the protocols and indications for neuroradiologic imaging performed on a modern whole-body, mid-field-strength 0.55-T MRI system. The overall image quality of routine clinical brain and spinal imaging at 0.55 T is lower than that at 1.5 T but still diagnostic for many routine indications. The intrinsic benefits of using a lower main magnetic field strength may be leveraged for imaging intracranial and spinal hardware due to diminished susceptibility artifacts and pose new opportunities for increased MRI safety. In addition, the imaging of structures that are near bone, such as the internal auditory canal, may represent an opportunity for additional use of MRI with lower magnetic field strengths due to reduced magnetic susceptibility differences and greater field homogeneity. However, lower main magnetic field strength limits the use of frequency-selective fat saturation and introduces challenges for Dixon-based fat suppression. The limitations of one specific 0.55-T system include acceleration artifacts and insufficient signal intensity of dynamic contrast-enhanced susceptibility-weighted perfusion imaging, which precluded the evaluation of multiple sclerosis and primary brain tumors. Investigations of ongoing technical developments of 0.55-T MRI include exploring sequence structures that are particularly advantageous at lower field strengths, such as those in balanced steady-state free-precession and single-shot fast spin-echo MRI, which are being used in functional and fetal MRI. Deep learning algorithms are also being used to improve image quality while maintaining or reducing imaging times. <sup>©</sup>RSNA, 2025 Supplemental material is available for this article. See the invited commentary by Pai and Jabehdar Maralani in this issue.</p>\",\"PeriodicalId\":54512,\"journal\":{\"name\":\"Radiographics\",\"volume\":\"45 3\",\"pages\":\"e240076\"},\"PeriodicalIF\":5.2000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiographics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1148/rg.240076\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiographics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1148/rg.240076","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

用于诊断和评估神经系统疾病的MRI最常在1.5- t和3.0-T系统上进行。最近,磁共振成像可及性的提高,再加上软件和硬件的进步,激发了人们对磁场强度从0.064 T到1.0 T的MRI系统的新兴趣。作者描述了在现代全身、中场强度0.55 T MRI系统上进行神经放射成像的方案和适应症。临床常规脑和脊柱成像在0.55 T时的整体图像质量低于1.5 T,但仍可诊断许多常规适应症。使用较低的主磁场强度的内在好处,可以利用成像颅内和脊柱硬体,由于减少了敏感性伪影,并为提高MRI安全性提供了新的机会。此外,对骨附近的结构(如内耳道)的成像,由于磁化率差异减小和磁场均匀性增强,可能会有机会使用磁场强度较低的MRI。然而,较低的主磁场强度限制了频率选择性脂肪饱和的使用,并给基于dixon的脂肪抑制带来了挑战。一种特定的0.55-T系统的局限性包括加速伪影和动态对比增强敏感性加权灌注成像信号强度不足,这妨碍了多发性硬化症和原发性脑肿瘤的评估。正在进行的0.55-T MRI技术发展的研究包括探索在较低场强下特别有利的序列结构,例如平衡稳态自由进动和单次快速自旋回波MRI,它们正在用于功能和胎儿MRI。深度学习算法也被用于提高图像质量,同时保持或减少成像时间。©RSNA, 2025本文可获得补充材料。请参阅Pai和Jabehdar Maralani在本期的特邀评论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Routine and Advanced Neurologic Imaging at 0.55-T MRI: Opportunities and Challenges.

MRI for diagnosis and assessment of neurologic conditions is most commonly performed on 1.5- and 3.0-T systems. Recently, motivation to increase accessibility to MRI, coupled with advances in software and hardware, has sparked renewed interest in MRI systems with magnetic field strengths ranging from 0.064 T to 1.0 T. The authors describe the protocols and indications for neuroradiologic imaging performed on a modern whole-body, mid-field-strength 0.55-T MRI system. The overall image quality of routine clinical brain and spinal imaging at 0.55 T is lower than that at 1.5 T but still diagnostic for many routine indications. The intrinsic benefits of using a lower main magnetic field strength may be leveraged for imaging intracranial and spinal hardware due to diminished susceptibility artifacts and pose new opportunities for increased MRI safety. In addition, the imaging of structures that are near bone, such as the internal auditory canal, may represent an opportunity for additional use of MRI with lower magnetic field strengths due to reduced magnetic susceptibility differences and greater field homogeneity. However, lower main magnetic field strength limits the use of frequency-selective fat saturation and introduces challenges for Dixon-based fat suppression. The limitations of one specific 0.55-T system include acceleration artifacts and insufficient signal intensity of dynamic contrast-enhanced susceptibility-weighted perfusion imaging, which precluded the evaluation of multiple sclerosis and primary brain tumors. Investigations of ongoing technical developments of 0.55-T MRI include exploring sequence structures that are particularly advantageous at lower field strengths, such as those in balanced steady-state free-precession and single-shot fast spin-echo MRI, which are being used in functional and fetal MRI. Deep learning algorithms are also being used to improve image quality while maintaining or reducing imaging times. ©RSNA, 2025 Supplemental material is available for this article. See the invited commentary by Pai and Jabehdar Maralani in this issue.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiographics
Radiographics 医学-核医学
CiteScore
8.20
自引率
5.50%
发文量
224
审稿时长
4-8 weeks
期刊介绍: Launched by the Radiological Society of North America (RSNA) in 1981, RadioGraphics is one of the premier education journals in diagnostic radiology. Each bimonthly issue features 15–20 practice-focused articles spanning the full spectrum of radiologic subspecialties and addressing topics such as diagnostic imaging techniques, imaging features of a disease or group of diseases, radiologic-pathologic correlation, practice policy and quality initiatives, imaging physics, informatics, and lifelong learning. A special issue, a monograph focused on a single subspecialty or on a crossover topic of interest to multiple subspecialties, is published each October. Each issue offers more than a dozen opportunities to earn continuing medical education credits that qualify for AMA PRA Category 1 CreditTM and all online activities can be applied toward the ABR MOC Self-Assessment Requirement.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信