IF 1.2 Q4 OPHTHALMOLOGY
Saudi Journal of Ophthalmology Pub Date : 2024-12-02 eCollection Date: 2024-10-01 DOI:10.4103/sjopt.sjopt_138_24
Meindert Lauwers, Evelien Vandewalle, Sophie Lemmens
{"title":"家庭医疗保健-我们已经知道的。","authors":"Meindert Lauwers, Evelien Vandewalle, Sophie Lemmens","doi":"10.4103/sjopt.sjopt_138_24","DOIUrl":null,"url":null,"abstract":"<p><p>The only known modifiable risk factor for the development and progression of glaucoma is an increased intraocular pressure (IOP). Current follow-up with Goldmann applanation tonometry (GAT) constitutes a suboptimal approach, given out-of-office IOP peaks and fluctuations will not be exposed. Self-tonometry in the home environment could address this unmet need, detecting uncontrolled disease and potentially impacting further therapeutic management. Since recently, iCare HOME was developed as a handheld rebound tonometer for this purpose. The aim of this literature review is twofold. First, the accuracy of iCare HOME compared to GAT will be assessed, including evaluation of the influence of corneal characteristics and the mean IOP. Second, an overview of the reported feasibility and acceptance on the use of iCare HOME will be presented. The literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature was searched on Medline (via Pubmed), Embase, Cochrane Library, and Web of Science (Core Collection) on April 10, 2023. A total of 187 records were identified after deduplication, of which 20 articles were included after full evaluation of their suitability. This study reported that iCare HOME has a moderate to good accuracy compared to GAT and a tendency to underestimate GAT, with a median underestimation of 1 mmHg, ranging from 2.66 mmHg underestimation to 2.08 mmHg overestimation. Success rates ranged between 67.5% and 100% with a median rate of 82.5%. Sufficient acceptance was demonstrated. In conclusion, self-tonometry with iCare HOME constitutes an accurate, feasible, and accepted method for home monitoring of glaucoma, providing additional out-of-office IOP-data, and increasing patient empowerment.</p>","PeriodicalId":46810,"journal":{"name":"Saudi Journal of Ophthalmology","volume":"38 4","pages":"295-305"},"PeriodicalIF":1.2000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11811397/pdf/","citationCount":"0","resultStr":"{\"title\":\"Home iCare - What we already know.\",\"authors\":\"Meindert Lauwers, Evelien Vandewalle, Sophie Lemmens\",\"doi\":\"10.4103/sjopt.sjopt_138_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The only known modifiable risk factor for the development and progression of glaucoma is an increased intraocular pressure (IOP). Current follow-up with Goldmann applanation tonometry (GAT) constitutes a suboptimal approach, given out-of-office IOP peaks and fluctuations will not be exposed. Self-tonometry in the home environment could address this unmet need, detecting uncontrolled disease and potentially impacting further therapeutic management. Since recently, iCare HOME was developed as a handheld rebound tonometer for this purpose. The aim of this literature review is twofold. First, the accuracy of iCare HOME compared to GAT will be assessed, including evaluation of the influence of corneal characteristics and the mean IOP. Second, an overview of the reported feasibility and acceptance on the use of iCare HOME will be presented. The literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature was searched on Medline (via Pubmed), Embase, Cochrane Library, and Web of Science (Core Collection) on April 10, 2023. A total of 187 records were identified after deduplication, of which 20 articles were included after full evaluation of their suitability. This study reported that iCare HOME has a moderate to good accuracy compared to GAT and a tendency to underestimate GAT, with a median underestimation of 1 mmHg, ranging from 2.66 mmHg underestimation to 2.08 mmHg overestimation. Success rates ranged between 67.5% and 100% with a median rate of 82.5%. Sufficient acceptance was demonstrated. In conclusion, self-tonometry with iCare HOME constitutes an accurate, feasible, and accepted method for home monitoring of glaucoma, providing additional out-of-office IOP-data, and increasing patient empowerment.</p>\",\"PeriodicalId\":46810,\"journal\":{\"name\":\"Saudi Journal of Ophthalmology\",\"volume\":\"38 4\",\"pages\":\"295-305\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11811397/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saudi Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/sjopt.sjopt_138_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/sjopt.sjopt_138_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

青光眼发生和发展的唯一已知的可改变的危险因素是眼压升高。目前使用Goldmann压平眼压计(GAT)进行随访是一种次优方法,因为不会暴露在外眼压峰值和波动。家庭环境中的自我血压计可以解决这一未满足的需求,检测无法控制的疾病,并可能影响进一步的治疗管理。最近,iCare HOME被开发为一种手持式回弹眼压计。这篇文献综述的目的是双重的。首先,将对iCare HOME与GAT相比的准确性进行评估,包括评估角膜特征和平均眼压的影响。其次,概述了使用iCare HOME的可行性和可接受性。文献综述按照系统评价和荟萃分析指南的首选报告项目进行。文献于2023年4月10日在Medline(通过Pubmed)、Embase、Cochrane Library和Web of Science(核心馆藏)上检索。在重复数据删除后,共识别了187条记录,其中20篇文章在对其适用性进行充分评估后被纳入。本研究报道,与GAT相比,iCare HOME具有中等到良好的准确性,并且倾向于低估GAT,中位数低估1 mmHg,范围从低估2.66 mmHg到高估2.08 mmHg。成功率在67.5%到100%之间,中位数为82.5%。表现出充分的接受。综上所述,使用iCare HOME进行自我眼压测量是一种准确、可行且被接受的青光眼家庭监测方法,提供了额外的办公室外眼压数据,并增加了患者的授权。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Home iCare - What we already know.

The only known modifiable risk factor for the development and progression of glaucoma is an increased intraocular pressure (IOP). Current follow-up with Goldmann applanation tonometry (GAT) constitutes a suboptimal approach, given out-of-office IOP peaks and fluctuations will not be exposed. Self-tonometry in the home environment could address this unmet need, detecting uncontrolled disease and potentially impacting further therapeutic management. Since recently, iCare HOME was developed as a handheld rebound tonometer for this purpose. The aim of this literature review is twofold. First, the accuracy of iCare HOME compared to GAT will be assessed, including evaluation of the influence of corneal characteristics and the mean IOP. Second, an overview of the reported feasibility and acceptance on the use of iCare HOME will be presented. The literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature was searched on Medline (via Pubmed), Embase, Cochrane Library, and Web of Science (Core Collection) on April 10, 2023. A total of 187 records were identified after deduplication, of which 20 articles were included after full evaluation of their suitability. This study reported that iCare HOME has a moderate to good accuracy compared to GAT and a tendency to underestimate GAT, with a median underestimation of 1 mmHg, ranging from 2.66 mmHg underestimation to 2.08 mmHg overestimation. Success rates ranged between 67.5% and 100% with a median rate of 82.5%. Sufficient acceptance was demonstrated. In conclusion, self-tonometry with iCare HOME constitutes an accurate, feasible, and accepted method for home monitoring of glaucoma, providing additional out-of-office IOP-data, and increasing patient empowerment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
79
审稿时长
13 weeks
期刊介绍: Saudi Journal of Ophthalmology is an English language, peer-reviewed scholarly publication in the area of ophthalmology. Saudi Journal of Ophthalmology publishes original papers, clinical studies, reviews and case reports. Saudi Journal of Ophthalmology is the official publication of the Saudi Ophthalmological Society and is published by King Saud University in collaboration with Elsevier and is edited by an international group of eminent researchers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信