Anna Hsu, Sarah H Al Nemer, Peter Kfoury, Jordan Stout, Anna Holley, Caitlin Stone, Matthew Firpo, Albert Park
{"title":"耳膜穿孔时插入式耳机与耳机低频听力阈值的比较。","authors":"Anna Hsu, Sarah H Al Nemer, Peter Kfoury, Jordan Stout, Anna Holley, Caitlin Stone, Matthew Firpo, Albert Park","doi":"10.1002/oto2.70045","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare hearing thresholds at 250 and 500 Hz in pediatric patients with tympanic membrane perforations (TMP) using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones.</p><p><strong>Study design: </strong>Prospective clinical pilot study.</p><p><strong>Setting: </strong>Primary Children's Hospital, Utah.</p><p><strong>Methods: </strong>Children (<18 years of age) were prospectively enrolled into 2 groups based on the presence of TMPs (no TMP, TMP). Hearing thresholds were measured at 250 and 500 Hz using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones for all participants.</p><p><strong>Results: </strong>At 250 and 500 Hz, hearing thresholds were significantly higher when recorded with insert earphones than with supra-aural headphones in pediatric participants with TMPs. At 250 Hz, thresholds obtained with inserts were 14.7 ± 7.2 dB (<i>P</i> < .001) higher than thresholds obtained with supra-aural headphones and 8.0 ± 7.5 dB higher (<i>P</i> < .01) at 500 Hz.</p><p><strong>Conclusion: </strong>Low-frequency hearing thresholds were significantly higher when measured with insert earphones in patients with TMPsbut not in patients without TMPs. A diagnosis of low-frequency hearing loss must be interpreted with caution when using insert earphones in participants with TMPs.</p>","PeriodicalId":19697,"journal":{"name":"OTO Open","volume":"9 1","pages":"e70045"},"PeriodicalIF":1.8000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11815708/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparing Low-Frequency Hearing Thresholds between Insert Earphones and Headphones in Ears with Tympanic Membrane Perforations.\",\"authors\":\"Anna Hsu, Sarah H Al Nemer, Peter Kfoury, Jordan Stout, Anna Holley, Caitlin Stone, Matthew Firpo, Albert Park\",\"doi\":\"10.1002/oto2.70045\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To compare hearing thresholds at 250 and 500 Hz in pediatric patients with tympanic membrane perforations (TMP) using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones.</p><p><strong>Study design: </strong>Prospective clinical pilot study.</p><p><strong>Setting: </strong>Primary Children's Hospital, Utah.</p><p><strong>Methods: </strong>Children (<18 years of age) were prospectively enrolled into 2 groups based on the presence of TMPs (no TMP, TMP). Hearing thresholds were measured at 250 and 500 Hz using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones for all participants.</p><p><strong>Results: </strong>At 250 and 500 Hz, hearing thresholds were significantly higher when recorded with insert earphones than with supra-aural headphones in pediatric participants with TMPs. At 250 Hz, thresholds obtained with inserts were 14.7 ± 7.2 dB (<i>P</i> < .001) higher than thresholds obtained with supra-aural headphones and 8.0 ± 7.5 dB higher (<i>P</i> < .01) at 500 Hz.</p><p><strong>Conclusion: </strong>Low-frequency hearing thresholds were significantly higher when measured with insert earphones in patients with TMPsbut not in patients without TMPs. A diagnosis of low-frequency hearing loss must be interpreted with caution when using insert earphones in participants with TMPs.</p>\",\"PeriodicalId\":19697,\"journal\":{\"name\":\"OTO Open\",\"volume\":\"9 1\",\"pages\":\"e70045\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-02-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11815708/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"OTO Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/oto2.70045\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"OTO Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/oto2.70045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
Comparing Low-Frequency Hearing Thresholds between Insert Earphones and Headphones in Ears with Tympanic Membrane Perforations.
Objective: To compare hearing thresholds at 250 and 500 Hz in pediatric patients with tympanic membrane perforations (TMP) using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones.
Study design: Prospective clinical pilot study.
Setting: Primary Children's Hospital, Utah.
Methods: Children (<18 years of age) were prospectively enrolled into 2 groups based on the presence of TMPs (no TMP, TMP). Hearing thresholds were measured at 250 and 500 Hz using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones for all participants.
Results: At 250 and 500 Hz, hearing thresholds were significantly higher when recorded with insert earphones than with supra-aural headphones in pediatric participants with TMPs. At 250 Hz, thresholds obtained with inserts were 14.7 ± 7.2 dB (P < .001) higher than thresholds obtained with supra-aural headphones and 8.0 ± 7.5 dB higher (P < .01) at 500 Hz.
Conclusion: Low-frequency hearing thresholds were significantly higher when measured with insert earphones in patients with TMPsbut not in patients without TMPs. A diagnosis of low-frequency hearing loss must be interpreted with caution when using insert earphones in participants with TMPs.