3D-0D多尺度界面耦合的界面条件比较及其在组织灌注中的应用

IF 2.2 4区 医学 Q3 ENGINEERING, BIOMEDICAL
L. Bociu, M. Broussard, G. Guidoboni, D. Prada, S. Strikwerda
{"title":"3D-0D多尺度界面耦合的界面条件比较及其在组织灌注中的应用","authors":"L. Bociu,&nbsp;M. Broussard,&nbsp;G. Guidoboni,&nbsp;D. Prada,&nbsp;S. Strikwerda","doi":"10.1002/cnm.70017","DOIUrl":null,"url":null,"abstract":"<p>Many pathologies are related to hemodynamic changes occurring at the microvascular level, where small vessels pierce the tissue, perfusing it with blood. Since there is a large number of vessels of small caliber, it is impractical to model the fluid flow through each one of them separately, as it is done in the case of large arteries using, for example, the Navier–Stokes equations. As an alternative, tissue perfusion is modeled here via three-dimensional (3D) partial differential equations (PDEs) for fluid flow through deformable porous media, where blood vessels are modeled as pores within a deformable solid representing the tissue. Since it is known that the local perfusion is related to the systemic features of surrounding blood circulation, we couple the PDE system with a zero-dimensional (0D) lumped circuit model, obtained by the analogy between fluid flows in hydraulic networks and current flowing in electrical circuits. An important feature in this multiscale 3D–0D coupling is the specification of interface conditions between the 3D and the 0D parts of the system. In this article, we focus on two types of interface conditions driven by physical considerations, and compare the behavior of the solutions for the two different scenarios.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"41 2","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cnm.70017","citationCount":"0","resultStr":"{\"title\":\"Comparing Interface Conditions for a 3D–0D Multiscale Interface Coupling With Applications in Tissue Perfusion\",\"authors\":\"L. Bociu,&nbsp;M. Broussard,&nbsp;G. Guidoboni,&nbsp;D. Prada,&nbsp;S. Strikwerda\",\"doi\":\"10.1002/cnm.70017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Many pathologies are related to hemodynamic changes occurring at the microvascular level, where small vessels pierce the tissue, perfusing it with blood. Since there is a large number of vessels of small caliber, it is impractical to model the fluid flow through each one of them separately, as it is done in the case of large arteries using, for example, the Navier–Stokes equations. As an alternative, tissue perfusion is modeled here via three-dimensional (3D) partial differential equations (PDEs) for fluid flow through deformable porous media, where blood vessels are modeled as pores within a deformable solid representing the tissue. Since it is known that the local perfusion is related to the systemic features of surrounding blood circulation, we couple the PDE system with a zero-dimensional (0D) lumped circuit model, obtained by the analogy between fluid flows in hydraulic networks and current flowing in electrical circuits. An important feature in this multiscale 3D–0D coupling is the specification of interface conditions between the 3D and the 0D parts of the system. In this article, we focus on two types of interface conditions driven by physical considerations, and compare the behavior of the solutions for the two different scenarios.</p>\",\"PeriodicalId\":50349,\"journal\":{\"name\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"volume\":\"41 2\",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-02-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cnm.70017\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/cnm.70017\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.70017","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

许多疾病都与微血管水平发生的血流动力学变化有关,在微血管水平,小血管穿透组织,向其灌注血液。由于存在大量的小口径血管,因此不可能像用纳维-斯托克斯方程(Navier-Stokes equation)等方法来模拟大动脉的情况那样,单独模拟流体流过每一条血管的情况。作为一种替代方法,组织灌注在这里通过三维(3D)偏微分方程(PDEs)来模拟流体流过可变形多孔介质,其中血管被建模为代表组织的可变形固体中的孔隙。由于已知局部灌注与周围血液循环的系统特征有关,我们将PDE系统与零维(0D)集总电路模型相结合,该模型通过类比液压网络中的流体流动和电路中的电流流动而得到。这种多尺度3D - 0D耦合的一个重要特征是系统的3D和0D部分之间的接口条件的规范。在本文中,我们将重点讨论由物理因素驱动的两种类型的接口条件,并比较两种不同场景下解决方案的行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparing Interface Conditions for a 3D–0D Multiscale Interface Coupling With Applications in Tissue Perfusion

Comparing Interface Conditions for a 3D–0D Multiscale Interface Coupling With Applications in Tissue Perfusion

Many pathologies are related to hemodynamic changes occurring at the microvascular level, where small vessels pierce the tissue, perfusing it with blood. Since there is a large number of vessels of small caliber, it is impractical to model the fluid flow through each one of them separately, as it is done in the case of large arteries using, for example, the Navier–Stokes equations. As an alternative, tissue perfusion is modeled here via three-dimensional (3D) partial differential equations (PDEs) for fluid flow through deformable porous media, where blood vessels are modeled as pores within a deformable solid representing the tissue. Since it is known that the local perfusion is related to the systemic features of surrounding blood circulation, we couple the PDE system with a zero-dimensional (0D) lumped circuit model, obtained by the analogy between fluid flows in hydraulic networks and current flowing in electrical circuits. An important feature in this multiscale 3D–0D coupling is the specification of interface conditions between the 3D and the 0D parts of the system. In this article, we focus on two types of interface conditions driven by physical considerations, and compare the behavior of the solutions for the two different scenarios.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信