脑电参考方案对事件相关潜在结果的影响:基于说话/听范式的推论放电研究

IF 2.3 3区 医学 Q3 CLINICAL NEUROLOGY
Subham Samantaray, Nishant Goyal, Muralidharan Kesavan, Ganesan Venkatasubramanian, Anushree Bose, Umesh Shreekantiah, Vanteemar S Sreeraj, Manul Das, Justin Raj, Sujeet Kumar
{"title":"脑电参考方案对事件相关潜在结果的影响:基于说话/听范式的推论放电研究","authors":"Subham Samantaray, Nishant Goyal, Muralidharan Kesavan, Ganesan Venkatasubramanian, Anushree Bose, Umesh Shreekantiah, Vanteemar S Sreeraj, Manul Das, Justin Raj, Sujeet Kumar","doi":"10.1007/s10548-025-01103-4","DOIUrl":null,"url":null,"abstract":"<p><p>The selection of an appropriate virtual reference schema is pivotal in determining the outcomes of event-related potential (ERP) studies, particularly within the widely utilized Talk/Listen ERP paradigm, which is employed to non-invasively explore the corollary discharge phenomenon in the speech-auditory system. This research centers on examining the effects of prevalent EEG reference schemas-linked mastoids (LM), common average reference (CAR), and reference electrode standardization technique (REST)-through statistical analysis, statistical parametric scalp mapping (SPSM), and source localization techniques. Our ANOVA findings indicate significant main effects for both the reference and the experimental condition on the amplitude of N1 ERPs. Depending on the reference used, the polarity and amplitude of the N1 ERPs demonstrate systematic variations: LM is associated with pronounced frontocentral activity, whereas both CAR and REST exhibit patterns of frontocentral and occipitotemporal activity. The significance of SPSM results is confined to regions exhibiting prominent N1 activity for each reference schema. Source analysis provides corroborative evidence more aligned with the SPSM results for CAR and REST than for LM, suggesting that results under CAR and REST are more objective and reliable. Therefore, the CAR and REST reference are recommended for future studies involving Talk/Listen ERP paradigms.</p>","PeriodicalId":55329,"journal":{"name":"Brain Topography","volume":"38 2","pages":"30"},"PeriodicalIF":2.3000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of EEG Reference Schemes on Event-Related Potential Outcomes: A Corollary Discharge Study Using a Talk/Listen Paradigm.\",\"authors\":\"Subham Samantaray, Nishant Goyal, Muralidharan Kesavan, Ganesan Venkatasubramanian, Anushree Bose, Umesh Shreekantiah, Vanteemar S Sreeraj, Manul Das, Justin Raj, Sujeet Kumar\",\"doi\":\"10.1007/s10548-025-01103-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The selection of an appropriate virtual reference schema is pivotal in determining the outcomes of event-related potential (ERP) studies, particularly within the widely utilized Talk/Listen ERP paradigm, which is employed to non-invasively explore the corollary discharge phenomenon in the speech-auditory system. This research centers on examining the effects of prevalent EEG reference schemas-linked mastoids (LM), common average reference (CAR), and reference electrode standardization technique (REST)-through statistical analysis, statistical parametric scalp mapping (SPSM), and source localization techniques. Our ANOVA findings indicate significant main effects for both the reference and the experimental condition on the amplitude of N1 ERPs. Depending on the reference used, the polarity and amplitude of the N1 ERPs demonstrate systematic variations: LM is associated with pronounced frontocentral activity, whereas both CAR and REST exhibit patterns of frontocentral and occipitotemporal activity. The significance of SPSM results is confined to regions exhibiting prominent N1 activity for each reference schema. Source analysis provides corroborative evidence more aligned with the SPSM results for CAR and REST than for LM, suggesting that results under CAR and REST are more objective and reliable. Therefore, the CAR and REST reference are recommended for future studies involving Talk/Listen ERP paradigms.</p>\",\"PeriodicalId\":55329,\"journal\":{\"name\":\"Brain Topography\",\"volume\":\"38 2\",\"pages\":\"30\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-02-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brain Topography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10548-025-01103-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brain Topography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10548-025-01103-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

选择合适的虚拟参考图式是决定事件相关电位(ERP)研究结果的关键,特别是在广泛使用的Talk/Listen ERP范式中,该范式用于非侵入性地探索言语-听觉系统的必然放电现象。本研究的重点是通过统计分析、统计参数头皮映射(SPSM)和源定位技术,研究流行的脑电参考图式-链接乳突(LM)、共同平均参考(CAR)和参考电极标准化技术(REST)的影响。我们的方差分析结果表明,参考条件和实验条件对N1 ERPs的振幅都有显著的主要影响。根据所使用的参考资料,N1 erp的极性和振幅表现出系统的变化:LM与明显的额中央活动有关,而CAR和REST都表现出额中央和枕颞活动的模式。SPSM结果的显著性局限于对每个参考图式表现出显著N1活性的区域。来源分析提供的确证证据与CAR和REST的SPSM结果比LM更一致,表明CAR和REST的结果更客观可靠。因此,CAR和REST被推荐用于未来涉及Talk/Listen ERP范式的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of EEG Reference Schemes on Event-Related Potential Outcomes: A Corollary Discharge Study Using a Talk/Listen Paradigm.

The selection of an appropriate virtual reference schema is pivotal in determining the outcomes of event-related potential (ERP) studies, particularly within the widely utilized Talk/Listen ERP paradigm, which is employed to non-invasively explore the corollary discharge phenomenon in the speech-auditory system. This research centers on examining the effects of prevalent EEG reference schemas-linked mastoids (LM), common average reference (CAR), and reference electrode standardization technique (REST)-through statistical analysis, statistical parametric scalp mapping (SPSM), and source localization techniques. Our ANOVA findings indicate significant main effects for both the reference and the experimental condition on the amplitude of N1 ERPs. Depending on the reference used, the polarity and amplitude of the N1 ERPs demonstrate systematic variations: LM is associated with pronounced frontocentral activity, whereas both CAR and REST exhibit patterns of frontocentral and occipitotemporal activity. The significance of SPSM results is confined to regions exhibiting prominent N1 activity for each reference schema. Source analysis provides corroborative evidence more aligned with the SPSM results for CAR and REST than for LM, suggesting that results under CAR and REST are more objective and reliable. Therefore, the CAR and REST reference are recommended for future studies involving Talk/Listen ERP paradigms.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Brain Topography
Brain Topography 医学-临床神经学
CiteScore
4.70
自引率
7.40%
发文量
41
审稿时长
3 months
期刊介绍: Brain Topography publishes clinical and basic research on cognitive neuroscience and functional neurophysiology using the full range of imaging techniques including EEG, MEG, fMRI, TMS, diffusion imaging, spectroscopy, intracranial recordings, lesion studies, and related methods. Submissions combining multiple techniques are particularly encouraged, as well as reports of new and innovative methodologies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信