Bryan F Vaca-Cartagena, Rodrigo Funes-Ferrada, Alejandra Yu Lee-Mateus, Alanna Barrios-Ruiz, Sofia Valdes-Camacho, Francisco Alvarez, Tathagat Narula, Sebastian Fernandez-Bussy, David Abia-Trujillo
{"title":"肺移植中支气管吻合口开裂尺寸不匹配的缩小重叠支架术","authors":"Bryan F Vaca-Cartagena, Rodrigo Funes-Ferrada, Alejandra Yu Lee-Mateus, Alanna Barrios-Ruiz, Sofia Valdes-Camacho, Francisco Alvarez, Tathagat Narula, Sebastian Fernandez-Bussy, David Abia-Trujillo","doi":"10.1002/rcr2.70116","DOIUrl":null,"url":null,"abstract":"<p><p>Bronchial dehiscence is a known complication following lung transplantation. In cases involving extensive airway necrosis and air leaks, bronchoscopic placement of self-expanding metallic stents provides an effective and safe management strategy. These stents facilitate granulation and tissue reepithelialization. We present a case of bronchial anastomotic dehiscence size mismatch after a lung transplant. This complication was successfully managed using three stents placed via a telescoping technique with flexible bronchoscopy.</p>","PeriodicalId":45846,"journal":{"name":"Respirology Case Reports","volume":"13 2","pages":"e70116"},"PeriodicalIF":0.8000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11813537/pdf/","citationCount":"0","resultStr":"{\"title\":\"Downsizing Overlap Stenting for Bronchial Anastomotic Dehiscence Size Mismatch in Lung Transplant.\",\"authors\":\"Bryan F Vaca-Cartagena, Rodrigo Funes-Ferrada, Alejandra Yu Lee-Mateus, Alanna Barrios-Ruiz, Sofia Valdes-Camacho, Francisco Alvarez, Tathagat Narula, Sebastian Fernandez-Bussy, David Abia-Trujillo\",\"doi\":\"10.1002/rcr2.70116\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Bronchial dehiscence is a known complication following lung transplantation. In cases involving extensive airway necrosis and air leaks, bronchoscopic placement of self-expanding metallic stents provides an effective and safe management strategy. These stents facilitate granulation and tissue reepithelialization. We present a case of bronchial anastomotic dehiscence size mismatch after a lung transplant. This complication was successfully managed using three stents placed via a telescoping technique with flexible bronchoscopy.</p>\",\"PeriodicalId\":45846,\"journal\":{\"name\":\"Respirology Case Reports\",\"volume\":\"13 2\",\"pages\":\"e70116\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2025-02-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11813537/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Respirology Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/rcr2.70116\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respirology Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/rcr2.70116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
Downsizing Overlap Stenting for Bronchial Anastomotic Dehiscence Size Mismatch in Lung Transplant.
Bronchial dehiscence is a known complication following lung transplantation. In cases involving extensive airway necrosis and air leaks, bronchoscopic placement of self-expanding metallic stents provides an effective and safe management strategy. These stents facilitate granulation and tissue reepithelialization. We present a case of bronchial anastomotic dehiscence size mismatch after a lung transplant. This complication was successfully managed using three stents placed via a telescoping technique with flexible bronchoscopy.
期刊介绍:
Respirology Case Reports is an open-access online journal dedicated to the publication of original clinical case reports, case series, clinical images and clinical videos in all fields of respiratory medicine. The Journal encourages the international exchange between clinicians and researchers of experiences in diagnosing and treating uncommon diseases or diseases with unusual presentations. All manuscripts are peer-reviewed through a streamlined process that aims at providing a rapid turnaround time from submission to publication.