{"title":"临床玻璃体活检剥包技术。","authors":"Charles DeBoer, Cindy Zhao, Prithvi Mruthyunjaya, Vinit B Mahajan, Karen M Wai, Steven R Sanislo","doi":"10.1186/s40942-025-00639-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Vitreous biopsy is a common technique used to guide management of acute endophthalmitis and help differentiate between infectious and inflammatory conditions. Currently, in-clinic vitreous biopsy is performed with a 25-gauge needle, without the ability to cut vitreous, potentially leading to reduced diagnostic yield. Recent work demonstrated the ability to perform vitreous biopsy with an off-the-shelf vitreous cutter. However, this was limited by complexity of assembly. Here, a technique using a single peel pack vitrectomy cutter is demonstrated for in-clinic vitreous biopsy.</p><p><strong>Methods: </strong>A 25-gauge vitreous cutter is opened from a peel pack. The drive line is identified, cut to length, and attached to a 10 mL syringe. A 1 mL syringe is attached to the aspiration line. After a trocar is used to place a cannula in the pars plana, the vitreous cutter is introduced into the eye. Cutting is performed by an assistant actuating the 10 mL syringe while the surgeon aspirates from the 1 mL syringe. After sample is collected, antimicrobials are injected if required and the cannula is removed.</p><p><strong>Results: </strong>A peel pack technique simplifies assembly for an in-clinic vitreous biopsy using a manually actuated cutter.</p><p><strong>Conclusion: </strong>We present a novel, improved, and simplified technique for vitreous tap using a vitreous cutter provided in a single peel pack, actuated by a single syringe with minimal assembly prior to use. This technique may be more accessible for clinicians than prior techniques and does not require a surgical console.</p>","PeriodicalId":14289,"journal":{"name":"International Journal of Retina and Vitreous","volume":"11 1","pages":"15"},"PeriodicalIF":2.4000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11808987/pdf/","citationCount":"0","resultStr":"{\"title\":\"In-clinic vitreous biopsy peel pack technique.\",\"authors\":\"Charles DeBoer, Cindy Zhao, Prithvi Mruthyunjaya, Vinit B Mahajan, Karen M Wai, Steven R Sanislo\",\"doi\":\"10.1186/s40942-025-00639-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Vitreous biopsy is a common technique used to guide management of acute endophthalmitis and help differentiate between infectious and inflammatory conditions. Currently, in-clinic vitreous biopsy is performed with a 25-gauge needle, without the ability to cut vitreous, potentially leading to reduced diagnostic yield. Recent work demonstrated the ability to perform vitreous biopsy with an off-the-shelf vitreous cutter. However, this was limited by complexity of assembly. Here, a technique using a single peel pack vitrectomy cutter is demonstrated for in-clinic vitreous biopsy.</p><p><strong>Methods: </strong>A 25-gauge vitreous cutter is opened from a peel pack. The drive line is identified, cut to length, and attached to a 10 mL syringe. A 1 mL syringe is attached to the aspiration line. After a trocar is used to place a cannula in the pars plana, the vitreous cutter is introduced into the eye. Cutting is performed by an assistant actuating the 10 mL syringe while the surgeon aspirates from the 1 mL syringe. After sample is collected, antimicrobials are injected if required and the cannula is removed.</p><p><strong>Results: </strong>A peel pack technique simplifies assembly for an in-clinic vitreous biopsy using a manually actuated cutter.</p><p><strong>Conclusion: </strong>We present a novel, improved, and simplified technique for vitreous tap using a vitreous cutter provided in a single peel pack, actuated by a single syringe with minimal assembly prior to use. This technique may be more accessible for clinicians than prior techniques and does not require a surgical console.</p>\",\"PeriodicalId\":14289,\"journal\":{\"name\":\"International Journal of Retina and Vitreous\",\"volume\":\"11 1\",\"pages\":\"15\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11808987/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Retina and Vitreous\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s40942-025-00639-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Retina and Vitreous","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40942-025-00639-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:玻璃体活检是一种常用的技术,用于指导急性眼内炎的治疗,并有助于区分感染性和炎症性疾病。目前,临床上的玻璃体活检是用25号针进行的,不能切开玻璃体,这可能会导致诊断率降低。最近的工作证明了用现成的玻璃体切割器进行玻璃体活检的能力。然而,这受到组装复杂性的限制。在这里,一种技术,使用单一剥离包玻璃体切割刀具演示了在临床玻璃体活检。方法:25号玻璃体切割器从剥包中打开。确定驱动线,切到长度,并连接到10毫升注射器。将1ml注射器连接到抽吸线上。在使用套管针在平面部放置套管后,将玻璃体切割器引入眼睛。切割由助手驱动10ml注射器,而外科医生从1ml注射器中抽吸。样品收集后,如果需要,注射抗菌剂,并取出套管。结果:剥包技术简化了使用手动驱动切割机进行临床玻璃体活检的组装。结论:我们提出了一种新的、改进的、简化的玻璃体穿刺技术,使用玻璃体切割器提供在一个单一的剥离包中,由一个注射器驱动,使用前组装最少。与以前的技术相比,这种技术对临床医生来说可能更容易获得,并且不需要手术控制台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In-clinic vitreous biopsy peel pack technique.

Background: Vitreous biopsy is a common technique used to guide management of acute endophthalmitis and help differentiate between infectious and inflammatory conditions. Currently, in-clinic vitreous biopsy is performed with a 25-gauge needle, without the ability to cut vitreous, potentially leading to reduced diagnostic yield. Recent work demonstrated the ability to perform vitreous biopsy with an off-the-shelf vitreous cutter. However, this was limited by complexity of assembly. Here, a technique using a single peel pack vitrectomy cutter is demonstrated for in-clinic vitreous biopsy.

Methods: A 25-gauge vitreous cutter is opened from a peel pack. The drive line is identified, cut to length, and attached to a 10 mL syringe. A 1 mL syringe is attached to the aspiration line. After a trocar is used to place a cannula in the pars plana, the vitreous cutter is introduced into the eye. Cutting is performed by an assistant actuating the 10 mL syringe while the surgeon aspirates from the 1 mL syringe. After sample is collected, antimicrobials are injected if required and the cannula is removed.

Results: A peel pack technique simplifies assembly for an in-clinic vitreous biopsy using a manually actuated cutter.

Conclusion: We present a novel, improved, and simplified technique for vitreous tap using a vitreous cutter provided in a single peel pack, actuated by a single syringe with minimal assembly prior to use. This technique may be more accessible for clinicians than prior techniques and does not require a surgical console.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
4.30%
发文量
81
审稿时长
19 weeks
期刊介绍: International Journal of Retina and Vitreous focuses on the ophthalmic subspecialty of vitreoretinal disorders. The journal presents original articles on new approaches to diagnosis, outcomes of clinical trials, innovations in pharmacological therapy and surgical techniques, as well as basic science advances that impact clinical practice. Topical areas include, but are not limited to: -Imaging of the retina, choroid and vitreous -Innovations in optical coherence tomography (OCT) -Small-gauge vitrectomy, retinal detachment, chromovitrectomy -Electroretinography (ERG), microperimetry, other functional tests -Intraocular tumors -Retinal pharmacotherapy & drug delivery -Diabetic retinopathy & other vascular diseases -Age-related macular degeneration (AMD) & other macular entities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信