超级电容驱动的可穿戴生物传感器,用于从汗液中连续监测乳酸

IF 10.5 1区 生物学 Q1 BIOPHYSICS
Elham Asadian , Farzaneh Hekmat , Mohammad Hafezi Kahnamouei , Raheleh Mohammadpour , Saeed Shahrokhian , Pezhman Sasanpour
{"title":"超级电容驱动的可穿戴生物传感器,用于从汗液中连续监测乳酸","authors":"Elham Asadian ,&nbsp;Farzaneh Hekmat ,&nbsp;Mohammad Hafezi Kahnamouei ,&nbsp;Raheleh Mohammadpour ,&nbsp;Saeed Shahrokhian ,&nbsp;Pezhman Sasanpour","doi":"10.1016/j.bios.2025.117226","DOIUrl":null,"url":null,"abstract":"<div><div>The development of wearable sensing platforms for continuous monitoring of sweat biomarkers has gained significant attention, particularly for lactate detection. This study presents the design and fabrication of a novel wearable lactate biosensor that integrates a flexible supercapacitor power supply with an advanced lactate sensing platform. The sensing platform features NiCo nanosheets electrodeposited onto nanocages of bimetallic CoFe Prussian Blue analogue (PBA), providing an optimal microenvironment for the immobilization of lactate oxidase (LOx) enzymes. The CoFe PBA nanocages act as efficient electrocatalysts for the reduction of hydrogen peroxide, enhancing the sensor's performance. The electrode exhibits a sensitivity of 262 μA mM<sup>-1</sup>cm<sup>-2</sup> and demonstrates a short response time (&lt;5 s), making it suitable for real-time monitoring applications. Additionally, the energy supply unit is constructed using a wearable conductive carbon textile (CCT) substrate modified with NiCoS through electrochemical deposition, achieving the necessary electrical conductivity. A flexible asymmetric supercapacitor (ASC) is then developed utilizing NiCoS@CCT and FeS@CNT@CCT as the positive and negative electrodes, respectively. This ASC exhibits remarkable electrochemical properties, including a high specific capacitance of 205 F g⁻<sup>1</sup>, notable energy density at elevated power densities, and excellent rate capability. Integrating these components with a custom-designed electronic circuit board results in a lightweight wearable sensor capable of continuous lactate monitoring in perspiration. This innovative approach demonstrates significant potential for advancing point-of-care health monitoring technologies.</div></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"275 ","pages":"Article 117226"},"PeriodicalIF":10.5000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Supercapacitor-powered wearable biosensor for continuous lactate monitoring from sweat\",\"authors\":\"Elham Asadian ,&nbsp;Farzaneh Hekmat ,&nbsp;Mohammad Hafezi Kahnamouei ,&nbsp;Raheleh Mohammadpour ,&nbsp;Saeed Shahrokhian ,&nbsp;Pezhman Sasanpour\",\"doi\":\"10.1016/j.bios.2025.117226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The development of wearable sensing platforms for continuous monitoring of sweat biomarkers has gained significant attention, particularly for lactate detection. This study presents the design and fabrication of a novel wearable lactate biosensor that integrates a flexible supercapacitor power supply with an advanced lactate sensing platform. The sensing platform features NiCo nanosheets electrodeposited onto nanocages of bimetallic CoFe Prussian Blue analogue (PBA), providing an optimal microenvironment for the immobilization of lactate oxidase (LOx) enzymes. The CoFe PBA nanocages act as efficient electrocatalysts for the reduction of hydrogen peroxide, enhancing the sensor's performance. The electrode exhibits a sensitivity of 262 μA mM<sup>-1</sup>cm<sup>-2</sup> and demonstrates a short response time (&lt;5 s), making it suitable for real-time monitoring applications. Additionally, the energy supply unit is constructed using a wearable conductive carbon textile (CCT) substrate modified with NiCoS through electrochemical deposition, achieving the necessary electrical conductivity. A flexible asymmetric supercapacitor (ASC) is then developed utilizing NiCoS@CCT and FeS@CNT@CCT as the positive and negative electrodes, respectively. This ASC exhibits remarkable electrochemical properties, including a high specific capacitance of 205 F g⁻<sup>1</sup>, notable energy density at elevated power densities, and excellent rate capability. Integrating these components with a custom-designed electronic circuit board results in a lightweight wearable sensor capable of continuous lactate monitoring in perspiration. This innovative approach demonstrates significant potential for advancing point-of-care health monitoring technologies.</div></div>\",\"PeriodicalId\":259,\"journal\":{\"name\":\"Biosensors and Bioelectronics\",\"volume\":\"275 \",\"pages\":\"Article 117226\"},\"PeriodicalIF\":10.5000,\"publicationDate\":\"2025-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors and Bioelectronics\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0956566325001009\",\"RegionNum\":1,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0956566325001009","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

用于连续监测汗液生物标志物的可穿戴传感平台的开发已经引起了极大的关注,特别是乳酸检测。本研究提出了一种新型可穿戴乳酸生物传感器的设计和制造,该传感器集成了柔性超级电容器电源和先进的乳酸传感平台。该传感平台将NiCo纳米片电沉积在双金属CoFe普鲁士蓝类似物(PBA)的纳米笼上,为固定化乳酸氧化酶(LOx)提供了最佳微环境。fe - PBA纳米笼作为过氧化氢还原的高效电催化剂,提高了传感器的性能。该电极的灵敏度为262 μA mM-1cm-2,响应时间短(5 s),适合于实时监测应用。此外,能源供应单元使用可穿戴的导电碳纺织(CCT)衬底构建,通过电化学沉积改性NiCoS,实现必要的导电性。然后分别利用NiCoS@CCT和FeS@CNT@CCT作为正极和负极开发了柔性非对称超级电容器(ASC)。这种ASC具有显著的电化学性能,包括205 F - 1的高比电容,在高功率密度下的显著能量密度,以及出色的速率能力。将这些组件与定制设计的电子电路板集成在一起,形成了一种轻便的可穿戴传感器,能够连续监测汗水中的乳酸。这一创新方法显示了推进护理点健康监测技术的巨大潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Supercapacitor-powered wearable biosensor for continuous lactate monitoring from sweat

Supercapacitor-powered wearable biosensor for continuous lactate monitoring from sweat
The development of wearable sensing platforms for continuous monitoring of sweat biomarkers has gained significant attention, particularly for lactate detection. This study presents the design and fabrication of a novel wearable lactate biosensor that integrates a flexible supercapacitor power supply with an advanced lactate sensing platform. The sensing platform features NiCo nanosheets electrodeposited onto nanocages of bimetallic CoFe Prussian Blue analogue (PBA), providing an optimal microenvironment for the immobilization of lactate oxidase (LOx) enzymes. The CoFe PBA nanocages act as efficient electrocatalysts for the reduction of hydrogen peroxide, enhancing the sensor's performance. The electrode exhibits a sensitivity of 262 μA mM-1cm-2 and demonstrates a short response time (<5 s), making it suitable for real-time monitoring applications. Additionally, the energy supply unit is constructed using a wearable conductive carbon textile (CCT) substrate modified with NiCoS through electrochemical deposition, achieving the necessary electrical conductivity. A flexible asymmetric supercapacitor (ASC) is then developed utilizing NiCoS@CCT and FeS@CNT@CCT as the positive and negative electrodes, respectively. This ASC exhibits remarkable electrochemical properties, including a high specific capacitance of 205 F g⁻1, notable energy density at elevated power densities, and excellent rate capability. Integrating these components with a custom-designed electronic circuit board results in a lightweight wearable sensor capable of continuous lactate monitoring in perspiration. This innovative approach demonstrates significant potential for advancing point-of-care health monitoring technologies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors and Bioelectronics
Biosensors and Bioelectronics 工程技术-电化学
CiteScore
20.80
自引率
7.10%
发文量
1006
审稿时长
29 days
期刊介绍: Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信