{"title":"井型NaI(Tl) γ能谱仪检测99Tcm、131I和18F的效率研究","authors":"Jiayu Liu,&nbsp;Xiaojun Lu,&nbsp;Chao Zhao","doi":"10.1016/j.radmp.2024.12.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To assess the detection efficiencies of liquid radioisotopes in a well-type NaI(Tl) gamma spectrometer, focusing on the short-lived isotopes <sup>99</sup>Tc<sup>m</sup>, <sup>131</sup>I, and <sup>18</sup>F.</div></div><div><h3>Methods</h3><div>The detection efficiencies of liquid <sup>99</sup>Tc<sup>m</sup>, <sup>131</sup>I, and <sup>18</sup>F in a well-type NaI(Tl) gamma spectrometer were systematically investigated through calibration experiments and Monte Carlo simulations, and accounting for the coincidence-summing effect.</div></div><div><h3>Results</h3><div>The results indicated that the detection efficiencies of <sup>99</sup>Tc<sup>m</sup>, <sup>131</sup>I, and <sup>18</sup>F varied from 64.4% to 72.3%, 34.8%–43.1% and 27.3%–28.5% for different sample volumes ranging from 15 ​mL to 80 ​mL, respectively. The simulated detection efficiencies were highly consistent with the experimental results, with a largest relative deviation of 5% for the 3 radionuclides and 4 different sample volumes.</div></div><div><h3>Conclusion</h3><div>The consistent results between the calibration experiments and Monte Carlo simulations reveal that this measuring device possesses high detection efficiencies of <sup>99</sup>Tc<sup>m</sup>, <sup>131</sup>I, and <sup>18</sup>F, making it suitable for measuring low-level activity radioactive liquids, such as radioactive waste liquids to be discharged.</div></div>","PeriodicalId":34051,"journal":{"name":"Radiation Medicine and Protection","volume":"6 1","pages":"Pages 46-50"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on the detection efficiencies of liquid 99Tcm, 131I, and 18F in a well-type NaI(Tl) gamma spectrometer\",\"authors\":\"Jiayu Liu,&nbsp;Xiaojun Lu,&nbsp;Chao Zhao\",\"doi\":\"10.1016/j.radmp.2024.12.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>To assess the detection efficiencies of liquid radioisotopes in a well-type NaI(Tl) gamma spectrometer, focusing on the short-lived isotopes <sup>99</sup>Tc<sup>m</sup>, <sup>131</sup>I, and <sup>18</sup>F.</div></div><div><h3>Methods</h3><div>The detection efficiencies of liquid <sup>99</sup>Tc<sup>m</sup>, <sup>131</sup>I, and <sup>18</sup>F in a well-type NaI(Tl) gamma spectrometer were systematically investigated through calibration experiments and Monte Carlo simulations, and accounting for the coincidence-summing effect.</div></div><div><h3>Results</h3><div>The results indicated that the detection efficiencies of <sup>99</sup>Tc<sup>m</sup>, <sup>131</sup>I, and <sup>18</sup>F varied from 64.4% to 72.3%, 34.8%–43.1% and 27.3%–28.5% for different sample volumes ranging from 15 ​mL to 80 ​mL, respectively. The simulated detection efficiencies were highly consistent with the experimental results, with a largest relative deviation of 5% for the 3 radionuclides and 4 different sample volumes.</div></div><div><h3>Conclusion</h3><div>The consistent results between the calibration experiments and Monte Carlo simulations reveal that this measuring device possesses high detection efficiencies of <sup>99</sup>Tc<sup>m</sup>, <sup>131</sup>I, and <sup>18</sup>F, making it suitable for measuring low-level activity radioactive liquids, such as radioactive waste liquids to be discharged.</div></div>\",\"PeriodicalId\":34051,\"journal\":{\"name\":\"Radiation Medicine and Protection\",\"volume\":\"6 1\",\"pages\":\"Pages 46-50\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation Medicine and Protection\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666555724001187\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Medicine and Protection","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666555724001187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

摘要

目的评价井型NaI(Tl) γ能谱仪对短寿命同位素99Tcm、131I和18F的检测效率。方法通过标定实验和蒙特卡罗模拟,考虑重合求和效应,系统研究井型NaI(Tl)伽马能谱仪中99Tcm、131I和18F的检测效率。结果在15 ~ 80 mL样品体积范围内,99Tcm、131I和18F的检测效率分别为64.4% ~ 72.3%、34.8% ~ 43.1%和27.3% ~ 28.5%。模拟的检测效率与实验结果高度一致,对于3种放射性核素和4种不同的样品体积,最大的相对偏差为5%。结论标定实验结果与蒙特卡罗模拟结果一致,表明该测量装置具有99Tcm、131I和18F的高检测效率,适用于低活度放射性液体的测量,如放射性废液的排放。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on the detection efficiencies of liquid 99Tcm, 131I, and 18F in a well-type NaI(Tl) gamma spectrometer

Objective

To assess the detection efficiencies of liquid radioisotopes in a well-type NaI(Tl) gamma spectrometer, focusing on the short-lived isotopes 99Tcm, 131I, and 18F.

Methods

The detection efficiencies of liquid 99Tcm, 131I, and 18F in a well-type NaI(Tl) gamma spectrometer were systematically investigated through calibration experiments and Monte Carlo simulations, and accounting for the coincidence-summing effect.

Results

The results indicated that the detection efficiencies of 99Tcm, 131I, and 18F varied from 64.4% to 72.3%, 34.8%–43.1% and 27.3%–28.5% for different sample volumes ranging from 15 ​mL to 80 ​mL, respectively. The simulated detection efficiencies were highly consistent with the experimental results, with a largest relative deviation of 5% for the 3 radionuclides and 4 different sample volumes.

Conclusion

The consistent results between the calibration experiments and Monte Carlo simulations reveal that this measuring device possesses high detection efficiencies of 99Tcm, 131I, and 18F, making it suitable for measuring low-level activity radioactive liquids, such as radioactive waste liquids to be discharged.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation Medicine and Protection
Radiation Medicine and Protection Health Professions-Emergency Medical Services
CiteScore
2.10
自引率
0.00%
发文量
0
审稿时长
103 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信