{"title":"不同口内扫描仪在牙冠修复中的准确性评价。","authors":"Mojdeh Meisami-Azad, Mohammad Alihemmati, Sayed Shojaedin Shayegh, Mohammad Amin Bafandeh","doi":"10.11607/ijp.9223","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>This in vitro study aimed to assess the trueness and precision of various intraoral scanners (IOSs) in relation to endocrown restorations.</p><p><strong>Methods: </strong>One human mandibular molar was mounted within an acrylic resin block. The tooth was prepared for an endocrown restoration, involving a 2-millimeter cusp reduction, a 3.5-millimeter pulp chamber depth, and a butt joint margin. The sample was scanned by three different IOSs (3Shape TRIOS 4, Carestream 3800, and Medit i700), with 10 scans taken by each, and then converted into STL files. A high-precision scanner captured a reference scan, which was also converted into an STL file. Trueness was assessed by superimposing each sample scan onto the reference, while precision was determined by superimposing the STL files within each group. Statistical analysis was performed using one-way ANOVA with Tukey HSD post hoc test and the Mann Whitney U Test (α = 0.05).</p><p><strong>Results: </strong>The study found that TRIOS 4 exhibited the highest trueness. (22.44 ± 15.01 μm), followed by Medit i700 (24.59 ± 12.80 μm) and CS 3800 (29.05 ± 7.75 μm). In terms of precision, CS 3800 had the best results (21.55 ± 8.87 μm), followed by Medit i700 (43.80 ± 17.42 μm) and TRIOS 4 (47.28 ± 13.93 μm). Only the differences between the precision of the CS 3800 and the other two scanners were statistically significant.</p><p><strong>Conclusions: </strong>The study found that all three scanners had similar trueness, but CS 3800 had significantly better precision than the other two scanners. However, all of the scanners demonstrated acceptable levels of accuracy in the context of endocrown preparation.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-24"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Accuracy of Different Intraoral Scanners in Endocrown Restorations.\",\"authors\":\"Mojdeh Meisami-Azad, Mohammad Alihemmati, Sayed Shojaedin Shayegh, Mohammad Amin Bafandeh\",\"doi\":\"10.11607/ijp.9223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>This in vitro study aimed to assess the trueness and precision of various intraoral scanners (IOSs) in relation to endocrown restorations.</p><p><strong>Methods: </strong>One human mandibular molar was mounted within an acrylic resin block. The tooth was prepared for an endocrown restoration, involving a 2-millimeter cusp reduction, a 3.5-millimeter pulp chamber depth, and a butt joint margin. The sample was scanned by three different IOSs (3Shape TRIOS 4, Carestream 3800, and Medit i700), with 10 scans taken by each, and then converted into STL files. A high-precision scanner captured a reference scan, which was also converted into an STL file. Trueness was assessed by superimposing each sample scan onto the reference, while precision was determined by superimposing the STL files within each group. Statistical analysis was performed using one-way ANOVA with Tukey HSD post hoc test and the Mann Whitney U Test (α = 0.05).</p><p><strong>Results: </strong>The study found that TRIOS 4 exhibited the highest trueness. (22.44 ± 15.01 μm), followed by Medit i700 (24.59 ± 12.80 μm) and CS 3800 (29.05 ± 7.75 μm). In terms of precision, CS 3800 had the best results (21.55 ± 8.87 μm), followed by Medit i700 (43.80 ± 17.42 μm) and TRIOS 4 (47.28 ± 13.93 μm). Only the differences between the precision of the CS 3800 and the other two scanners were statistically significant.</p><p><strong>Conclusions: </strong>The study found that all three scanners had similar trueness, but CS 3800 had significantly better precision than the other two scanners. However, all of the scanners demonstrated acceptable levels of accuracy in the context of endocrown preparation.</p>\",\"PeriodicalId\":94232,\"journal\":{\"name\":\"The International journal of prosthodontics\",\"volume\":\"0 0\",\"pages\":\"1-24\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of prosthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.9223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本体外研究旨在评估各种口腔内扫描仪(iiss)在牙髓修复中的准确性和准确性。方法:将一颗人下颌磨牙固定在丙烯酸树脂块内。牙齿准备进行牙冠内修复,包括2毫米的牙尖复位,3.5毫米的牙髓腔深度和对接边缘。样本被三种不同的ios扫描(3Shape TRIOS 4、Carestream 3800和Medit i700),每种扫描10次,然后转换成STL文件。高精度扫描仪捕获了参考扫描,并将其转换为STL文件。通过将每个样本扫描叠加到参考文献上来评估真实性,而通过叠加每组内的STL文件来确定精度。统计学分析采用单因素方差分析,采用Tukey HSD事后检验和Mann Whitney U检验(α = 0.05)。结果:研究发现TRIOS 4的准确率最高。(22.44±15.01 μm),其次是Medit i700(24.59±12.80 μm)和CS 3800(29.05±7.75 μm)。CS 3800的测量精度最高(21.55±8.87 μm),其次是Medit i700(43.80±17.42 μm)和TRIOS 4(47.28±13.93 μm)。只有CS 3800和其他两种扫描仪之间的精度差异具有统计学意义。结论:研究发现三种扫描仪的准确率相似,但cs3800的准确率明显高于其他两种扫描仪。然而,所有的扫描仪在冠内准备的背景下显示出可接受的精度水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the Accuracy of Different Intraoral Scanners in Endocrown Restorations.

Aims: This in vitro study aimed to assess the trueness and precision of various intraoral scanners (IOSs) in relation to endocrown restorations.

Methods: One human mandibular molar was mounted within an acrylic resin block. The tooth was prepared for an endocrown restoration, involving a 2-millimeter cusp reduction, a 3.5-millimeter pulp chamber depth, and a butt joint margin. The sample was scanned by three different IOSs (3Shape TRIOS 4, Carestream 3800, and Medit i700), with 10 scans taken by each, and then converted into STL files. A high-precision scanner captured a reference scan, which was also converted into an STL file. Trueness was assessed by superimposing each sample scan onto the reference, while precision was determined by superimposing the STL files within each group. Statistical analysis was performed using one-way ANOVA with Tukey HSD post hoc test and the Mann Whitney U Test (α = 0.05).

Results: The study found that TRIOS 4 exhibited the highest trueness. (22.44 ± 15.01 μm), followed by Medit i700 (24.59 ± 12.80 μm) and CS 3800 (29.05 ± 7.75 μm). In terms of precision, CS 3800 had the best results (21.55 ± 8.87 μm), followed by Medit i700 (43.80 ± 17.42 μm) and TRIOS 4 (47.28 ± 13.93 μm). Only the differences between the precision of the CS 3800 and the other two scanners were statistically significant.

Conclusions: The study found that all three scanners had similar trueness, but CS 3800 had significantly better precision than the other two scanners. However, all of the scanners demonstrated acceptable levels of accuracy in the context of endocrown preparation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信