Gustavo R Mota, Jeffer E Sasaki, Mirelly R Rocha, Pedro Augusto Bianchi Da Fonseca, Bernardo N Ide, Kazushige Goto, Donizete Cicero X De Oliveira, Moacir Marocolo
{"title":"压缩裤袜减轻肌肉疲劳在芭蕾舞特定测试:一项试点研究。","authors":"Gustavo R Mota, Jeffer E Sasaki, Mirelly R Rocha, Pedro Augusto Bianchi Da Fonseca, Bernardo N Ide, Kazushige Goto, Donizete Cicero X De Oliveira, Moacir Marocolo","doi":"10.70252/WDGS4753","DOIUrl":null,"url":null,"abstract":"<p><p>Compression garments, utilized in sports and exercise for performance enhancement and recovery, lack sufficient well-controlled studies to overcome any potential placebo effect. Therefore, we tested whether wearing compressive pantyhose (CP) during the Ballet-specific aerobic fitness test (BAFT) would influence performance, recovery, physiological, and perceptual indicators. Additionally, this pilot study tested the feasibility of the research procedures and informed adjustments for the main study. Nine young classical ballerinas attended two sessions on different days: a) wearing CP (pressure of 20-30 mmHg) or b) wearing a placebo pantyhose ([PLA] no compression, containing an illusory effect) during the BAFT. We assessed heart rate (HR) and rating of perceived exertion (RPE) during the BAFT, perceived recovery (PRS), lower-limb delayed onset muscle soreness (DOMS) at Pre and 24 h Post, and standing heel-rise test performance at Pre, 30 min, and 24 h Post. No variables differed (p>0.05) between CP and PLA (e.g., HR mean over 5 BAFT phases: 178±14 bpm vs. 179±17 bpm, p=0.63; RPE 30 min post: 9.1±0.8 vs. 9.1±0.8 arbitrary units, p=0.94). However, wearing CP promoted attenuation in acute fatigue, while PLA showed a performance decrement (p<0.05) 30 min Post in the standing heel-rise test: CP 30.2±6.0 to 22.8±7.5 repetitions and PLA 36.2±11.7 to 22.9±6.3 repetitions. We conclude that CP may mitigate acute fatigue in the triceps <i>surae</i> muscle of amateur classical ballet dancers, making it relevant for their acute recovery, particularly in cases involving multiple daily performances. Additionally, this pilot study confirmed the feasibility of the procedures.</p>","PeriodicalId":14171,"journal":{"name":"International journal of exercise science","volume":"18 2","pages":"92-106"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11798547/pdf/","citationCount":"0","resultStr":"{\"title\":\"Compressive Pantyhose Mitigates Muscle Fatigue in Ballet-Specific Test: A Pilot Study.\",\"authors\":\"Gustavo R Mota, Jeffer E Sasaki, Mirelly R Rocha, Pedro Augusto Bianchi Da Fonseca, Bernardo N Ide, Kazushige Goto, Donizete Cicero X De Oliveira, Moacir Marocolo\",\"doi\":\"10.70252/WDGS4753\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Compression garments, utilized in sports and exercise for performance enhancement and recovery, lack sufficient well-controlled studies to overcome any potential placebo effect. Therefore, we tested whether wearing compressive pantyhose (CP) during the Ballet-specific aerobic fitness test (BAFT) would influence performance, recovery, physiological, and perceptual indicators. Additionally, this pilot study tested the feasibility of the research procedures and informed adjustments for the main study. Nine young classical ballerinas attended two sessions on different days: a) wearing CP (pressure of 20-30 mmHg) or b) wearing a placebo pantyhose ([PLA] no compression, containing an illusory effect) during the BAFT. We assessed heart rate (HR) and rating of perceived exertion (RPE) during the BAFT, perceived recovery (PRS), lower-limb delayed onset muscle soreness (DOMS) at Pre and 24 h Post, and standing heel-rise test performance at Pre, 30 min, and 24 h Post. No variables differed (p>0.05) between CP and PLA (e.g., HR mean over 5 BAFT phases: 178±14 bpm vs. 179±17 bpm, p=0.63; RPE 30 min post: 9.1±0.8 vs. 9.1±0.8 arbitrary units, p=0.94). However, wearing CP promoted attenuation in acute fatigue, while PLA showed a performance decrement (p<0.05) 30 min Post in the standing heel-rise test: CP 30.2±6.0 to 22.8±7.5 repetitions and PLA 36.2±11.7 to 22.9±6.3 repetitions. We conclude that CP may mitigate acute fatigue in the triceps <i>surae</i> muscle of amateur classical ballet dancers, making it relevant for their acute recovery, particularly in cases involving multiple daily performances. Additionally, this pilot study confirmed the feasibility of the procedures.</p>\",\"PeriodicalId\":14171,\"journal\":{\"name\":\"International journal of exercise science\",\"volume\":\"18 2\",\"pages\":\"92-106\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11798547/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of exercise science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.70252/WDGS4753\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of exercise science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.70252/WDGS4753","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0
摘要
在运动和锻炼中用于提高成绩和恢复的压缩服装,缺乏足够的良好对照研究来克服任何潜在的安慰剂效应。因此,我们测试了在芭蕾专项有氧健身测试(BAFT)中穿着压缩连裤袜(CP)是否会影响表现、恢复、生理和知觉指标。此外,该试点研究测试了研究程序的可行性,并为主要研究提供了调整信息。九名年轻的古典芭蕾舞演员在不同的日子参加了两个阶段:a)在BAFT期间穿着CP(压力20-30毫米汞柱)或b)穿着安慰剂连裤袜([PLA]无压力,含有错觉效果)。我们评估了BAFT期间的心率(HR)和感知运动等级(RPE),感知恢复(PRS),下肢延迟性肌肉酸痛(DOMS),以及在BAFT前、30分钟和24小时后的站立脚跟上升测试表现。CP和PLA之间没有变量差异(p>0.05)(例如,5个BAFT期的HR平均值:178±14 bpm对179±17 bpm, p=0.63;30min后RPE: 9.1±0.8 vs. 9.1±0.8任意单位,p=0.94)。然而,佩戴CP促进急性疲劳的衰减,而PLA显示业余古典芭蕾舞者的表现下降(压肌),这与他们的急性恢复有关,特别是在涉及多次日常表演的情况下。此外,这项初步研究证实了这些程序的可行性。
Compressive Pantyhose Mitigates Muscle Fatigue in Ballet-Specific Test: A Pilot Study.
Compression garments, utilized in sports and exercise for performance enhancement and recovery, lack sufficient well-controlled studies to overcome any potential placebo effect. Therefore, we tested whether wearing compressive pantyhose (CP) during the Ballet-specific aerobic fitness test (BAFT) would influence performance, recovery, physiological, and perceptual indicators. Additionally, this pilot study tested the feasibility of the research procedures and informed adjustments for the main study. Nine young classical ballerinas attended two sessions on different days: a) wearing CP (pressure of 20-30 mmHg) or b) wearing a placebo pantyhose ([PLA] no compression, containing an illusory effect) during the BAFT. We assessed heart rate (HR) and rating of perceived exertion (RPE) during the BAFT, perceived recovery (PRS), lower-limb delayed onset muscle soreness (DOMS) at Pre and 24 h Post, and standing heel-rise test performance at Pre, 30 min, and 24 h Post. No variables differed (p>0.05) between CP and PLA (e.g., HR mean over 5 BAFT phases: 178±14 bpm vs. 179±17 bpm, p=0.63; RPE 30 min post: 9.1±0.8 vs. 9.1±0.8 arbitrary units, p=0.94). However, wearing CP promoted attenuation in acute fatigue, while PLA showed a performance decrement (p<0.05) 30 min Post in the standing heel-rise test: CP 30.2±6.0 to 22.8±7.5 repetitions and PLA 36.2±11.7 to 22.9±6.3 repetitions. We conclude that CP may mitigate acute fatigue in the triceps surae muscle of amateur classical ballet dancers, making it relevant for their acute recovery, particularly in cases involving multiple daily performances. Additionally, this pilot study confirmed the feasibility of the procedures.