标准护理假体保肢技术与犬桡骨远端无不锈钢钢板间隙组的生物力学比较。

IF 1.3 3区 农林科学 Q2 VETERINARY SCIENCES
American journal of veterinary research Pub Date : 2025-02-06 Print Date: 2025-04-01 DOI:10.2460/ajvr.24.11.0364
Josep Aisa, James W Johnson, Brandan G Wustefeld-Janssens
{"title":"标准护理假体保肢技术与犬桡骨远端无不锈钢钢板间隙组的生物力学比较。","authors":"Josep Aisa, James W Johnson, Brandan G Wustefeld-Janssens","doi":"10.2460/ajvr.24.11.0364","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the biomechanical properties of standard-of-care limb salvage stainless steel plates with metal endoprosthesis constructs to constructs without endoprosthesis.</p><p><strong>Methods: </strong>This was a cadaveric biomechanical study including 5 pairs of normal canine thoracic limbs randomly allocated into 2 groups: limbs with a second-generation, 11.5-mm Veterinary Orthopedic Implants stainless steel plate and a 122-mm stainless steel with endoprosthesis (SS-E) and limbs without endoprostheses or stainless steel with a gap (SS-G). Standard limb-spare surgery was performed and reconstructed with or without endoprostheses (ie, gap). Limbs were tested in axial loading until failure, and load-deformation curves were used to determine the biomechanical properties of the constructs, compared using a Wilcoxon matched-pairs signed-rank test. Failure modes were compared descriptively.</p><p><strong>Results: </strong>Yield load (644 ± 523 N and 288 ± 153 N), yield energy absorbed (1,126 ± 1,695 N/mm and 239 ± 251 N/mm), and ultimate energy absorbed (39,732 ± 11,679 N/mm and 5,175 ± 878 N/mm) were significantly different between the SS-E and SS-G groups, respectively. Stiffness (360 ± 64 N/mm and 180 ± 50 N/mm) and ultimate load (3,385 ± 512 N and 747 ± 98 N) were not. The mode of failure varied between groups, with 2 SS-E constructs failing by humeral fracture and 3 by plate bending at the most distal radial or radiocarpal screw holes, whereas all SS-G constructs failed by plate bending midgap.</p><p><strong>Conclusions: </strong>Limbs incorporating endoprosthesis were biomechanically superior to limbs reconstructed with a gap.</p><p><strong>Clinical relevance: </strong>Limbs reconstructed with locking 11.5-mm Veterinary Orthopedic Implants plates without endoprosthesis may fail at physiological forces during trot or run.</p>","PeriodicalId":7754,"journal":{"name":"American journal of veterinary research","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanical comparison of standard-of-care endoprosthesis limb-sparing technique to a gap group with stainless steel plates and no endoprostheses in the distal radial site of dogs.\",\"authors\":\"Josep Aisa, James W Johnson, Brandan G Wustefeld-Janssens\",\"doi\":\"10.2460/ajvr.24.11.0364\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To compare the biomechanical properties of standard-of-care limb salvage stainless steel plates with metal endoprosthesis constructs to constructs without endoprosthesis.</p><p><strong>Methods: </strong>This was a cadaveric biomechanical study including 5 pairs of normal canine thoracic limbs randomly allocated into 2 groups: limbs with a second-generation, 11.5-mm Veterinary Orthopedic Implants stainless steel plate and a 122-mm stainless steel with endoprosthesis (SS-E) and limbs without endoprostheses or stainless steel with a gap (SS-G). Standard limb-spare surgery was performed and reconstructed with or without endoprostheses (ie, gap). Limbs were tested in axial loading until failure, and load-deformation curves were used to determine the biomechanical properties of the constructs, compared using a Wilcoxon matched-pairs signed-rank test. Failure modes were compared descriptively.</p><p><strong>Results: </strong>Yield load (644 ± 523 N and 288 ± 153 N), yield energy absorbed (1,126 ± 1,695 N/mm and 239 ± 251 N/mm), and ultimate energy absorbed (39,732 ± 11,679 N/mm and 5,175 ± 878 N/mm) were significantly different between the SS-E and SS-G groups, respectively. Stiffness (360 ± 64 N/mm and 180 ± 50 N/mm) and ultimate load (3,385 ± 512 N and 747 ± 98 N) were not. The mode of failure varied between groups, with 2 SS-E constructs failing by humeral fracture and 3 by plate bending at the most distal radial or radiocarpal screw holes, whereas all SS-G constructs failed by plate bending midgap.</p><p><strong>Conclusions: </strong>Limbs incorporating endoprosthesis were biomechanically superior to limbs reconstructed with a gap.</p><p><strong>Clinical relevance: </strong>Limbs reconstructed with locking 11.5-mm Veterinary Orthopedic Implants plates without endoprosthesis may fail at physiological forces during trot or run.</p>\",\"PeriodicalId\":7754,\"journal\":{\"name\":\"American journal of veterinary research\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-02-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of veterinary research\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.2460/ajvr.24.11.0364\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/4/1 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of veterinary research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.2460/ajvr.24.11.0364","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/1 0:00:00","PubModel":"Print","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较带金属假体和不带金属假体的标准保肢不锈钢钢板的生物力学性能。方法:采用尸体生物力学研究方法,选取5对正常犬胸肢,随机分为2组:采用第二代11.5 mm Veterinary Orthopedic implant不锈钢钢板和122 mm不锈钢内假体(SS-E)和不采用内假体或带间隙不锈钢(SS-G)的胸肢。进行标准的残肢手术,并在有无假体(即间隙)的情况下进行重建。四肢在轴向载荷下进行测试,直到失效,并使用载荷-变形曲线来确定构建物的生物力学特性,使用Wilcoxon配对对带符号秩检验进行比较。对失效模式进行了描述性比较。结果:屈服负荷(644±523 N和288±153 N)、屈服能量吸收(1,126±1,695 N/mm和239±251 N/mm)和极限能量吸收(39,732±11,679 N/mm和5,175±878 N/mm)在SS-E组和SS-G组之间分别有显著差异。刚度(360±64 N/mm和180±50 N/mm)和极限载荷(3,385±512 N和747±98 N)没有变化。两组间的失败模式各不相同,2个SS-E型假体因肱骨骨折失败,3个因桡骨或桡腕骨远端螺钉孔处钢板弯曲失败,而所有SS-G型假体均因中间间隙钢板弯曲失败。结论:置入假体的义肢生物力学性能优于置入间隙义肢。临床相关性:在小跑或跑步过程中,用不带内假体的11.5 mm兽医骨科植入物钢板重建肢体可能会在生理力作用下失效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Biomechanical comparison of standard-of-care endoprosthesis limb-sparing technique to a gap group with stainless steel plates and no endoprostheses in the distal radial site of dogs.

Objective: To compare the biomechanical properties of standard-of-care limb salvage stainless steel plates with metal endoprosthesis constructs to constructs without endoprosthesis.

Methods: This was a cadaveric biomechanical study including 5 pairs of normal canine thoracic limbs randomly allocated into 2 groups: limbs with a second-generation, 11.5-mm Veterinary Orthopedic Implants stainless steel plate and a 122-mm stainless steel with endoprosthesis (SS-E) and limbs without endoprostheses or stainless steel with a gap (SS-G). Standard limb-spare surgery was performed and reconstructed with or without endoprostheses (ie, gap). Limbs were tested in axial loading until failure, and load-deformation curves were used to determine the biomechanical properties of the constructs, compared using a Wilcoxon matched-pairs signed-rank test. Failure modes were compared descriptively.

Results: Yield load (644 ± 523 N and 288 ± 153 N), yield energy absorbed (1,126 ± 1,695 N/mm and 239 ± 251 N/mm), and ultimate energy absorbed (39,732 ± 11,679 N/mm and 5,175 ± 878 N/mm) were significantly different between the SS-E and SS-G groups, respectively. Stiffness (360 ± 64 N/mm and 180 ± 50 N/mm) and ultimate load (3,385 ± 512 N and 747 ± 98 N) were not. The mode of failure varied between groups, with 2 SS-E constructs failing by humeral fracture and 3 by plate bending at the most distal radial or radiocarpal screw holes, whereas all SS-G constructs failed by plate bending midgap.

Conclusions: Limbs incorporating endoprosthesis were biomechanically superior to limbs reconstructed with a gap.

Clinical relevance: Limbs reconstructed with locking 11.5-mm Veterinary Orthopedic Implants plates without endoprosthesis may fail at physiological forces during trot or run.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
10.00%
发文量
186
审稿时长
3 months
期刊介绍: The American Journal of Veterinary Research supports the collaborative exchange of information between researchers and clinicians by publishing novel research findings that bridge the gulf between basic research and clinical practice or that help to translate laboratory research and preclinical studies to the development of clinical trials and clinical practice. The journal welcomes submission of high-quality original studies and review articles in a wide range of scientific fields, including anatomy, anesthesiology, animal welfare, behavior, epidemiology, genetics, heredity, infectious disease, molecular biology, oncology, pharmacology, pathogenic mechanisms, physiology, surgery, theriogenology, toxicology, and vaccinology. Species of interest include production animals, companion animals, equids, exotic animals, birds, reptiles, and wild and marine animals. Reports of laboratory animal studies and studies involving the use of animals as experimental models of human diseases are considered only when the study results are of demonstrable benefit to the species used in the research or to another species of veterinary interest. Other fields of interest or animals species are not necessarily excluded from consideration, but such reports must focus on novel research findings. Submitted papers must make an original and substantial contribution to the veterinary medicine knowledge base; preliminary studies are not appropriate.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信