IF 1.8 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS
Anil Kollapareddy, Kousrali Sayyad, Leela Prasad Kowtharapu, Naresh Konduru, Tanmoy Mondal, Mohan Varkolu, Sreedhar Gundekari
{"title":"Bioanalytical Tandem Mass Spectrometry Method for Precise Measurement of Tranexamic Acid in Human Plasma With Unveiling Methodological Advancement: Green Assessment With Advanced Metrics","authors":"Anil Kollapareddy,&nbsp;Kousrali Sayyad,&nbsp;Leela Prasad Kowtharapu,&nbsp;Naresh Konduru,&nbsp;Tanmoy Mondal,&nbsp;Mohan Varkolu,&nbsp;Sreedhar Gundekari","doi":"10.1002/bmc.6086","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>For the control of excessive blood loss occurring from major trauma, postpartum bleeding, surgery, or hereditary angioedema, antifibrinolytic compound tranexamic acid (TXM) is highly efficient in controlling blood loss by reversibly binding with on lysine receptor sites. A selective and sensitive method has been developed and validated for the quantitation of TXM in human plasma using high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS). Tranexamic acid-D2 (TXM-D2) was used as internal standard (ISTD) to minimize the errors in TXM quantification. TXM quantification was performed with positive polarity mode using a Shimadzu high performance liquid chromatography coupled with AB-SCIEX API-4000 tandem mass spectrometer. A Zorbax Eclipse C18 (150 × 4.6 mm, 5 μ) column was used for the TXM quantification, 8-mM ammonium formate buffer with 0.1% formic acid ionization enhancer was used as a mobile phase-A, and acetonitrile was used as a mobile phase-B. (38:62) v/v portion of mobile phases A and B selected to elute the TXM and TXM-D2 with the flow rate of 0.8 mL/min. An electrospray ionization (ESI) technique was selected for detection of TXM in the human plasma. Linearity was assessed in the concentration range from 75 to 15,000 ng/mL by using least squares of weighting factor linear regression (1/X<sup>2</sup>).</p>\n </div>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 3","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.6086","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

为控制因重大创伤、产后出血、手术或遗传性血管性水肿引起的失血过多,抗纤维蛋白溶解化合物氨甲环酸(TXM)通过与赖氨酸受体位点可逆结合,可有效控制失血。本研究采用高效液相色谱-串联质谱(HPLC-MS/MS)技术,开发并验证了一种选择性强、灵敏度高的方法,用于定量检测人体血浆中的氨甲环酸。使用氨甲环酸-D2(TXM-D2)作为内标(ISTD),以减少 TXM 定量的误差。TXM 定量采用岛津高效液相色谱-AB-SCIEX API-4000 串联质谱仪的正极性模式。采用 Zorbax Eclipse C18 (150 × 4.6 mm, 5 μ)色谱柱进行 TXM 定量分析,流动相 A 为 8-mM 甲酸铵缓冲液,含 0.1% 甲酸电离增强剂;流动相 B 为乙腈,流速为 0.8 mL/min。选用电喷雾离子化(ESI)技术检测人体血浆中的 TXM。在 75 至 15,000 纳克/毫升的浓度范围内,使用加权因子线性回归最小二乘法(1/X2)评估线性度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bioanalytical Tandem Mass Spectrometry Method for Precise Measurement of Tranexamic Acid in Human Plasma With Unveiling Methodological Advancement: Green Assessment With Advanced Metrics

For the control of excessive blood loss occurring from major trauma, postpartum bleeding, surgery, or hereditary angioedema, antifibrinolytic compound tranexamic acid (TXM) is highly efficient in controlling blood loss by reversibly binding with on lysine receptor sites. A selective and sensitive method has been developed and validated for the quantitation of TXM in human plasma using high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS). Tranexamic acid-D2 (TXM-D2) was used as internal standard (ISTD) to minimize the errors in TXM quantification. TXM quantification was performed with positive polarity mode using a Shimadzu high performance liquid chromatography coupled with AB-SCIEX API-4000 tandem mass spectrometer. A Zorbax Eclipse C18 (150 × 4.6 mm, 5 μ) column was used for the TXM quantification, 8-mM ammonium formate buffer with 0.1% formic acid ionization enhancer was used as a mobile phase-A, and acetonitrile was used as a mobile phase-B. (38:62) v/v portion of mobile phases A and B selected to elute the TXM and TXM-D2 with the flow rate of 0.8 mL/min. An electrospray ionization (ESI) technique was selected for detection of TXM in the human plasma. Linearity was assessed in the concentration range from 75 to 15,000 ng/mL by using least squares of weighting factor linear regression (1/X2).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信