吉隆坡医院常规核医学实践中残留[99mTc]Tc-Tetrofosmin活性的评估

IF 1 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Ren Yi Fong, Nurul Maisara Jaffar, Rachel Jen Lyn Chung, Hui Ling Tong, Syifaa' Aminudin, Kee Wei Lau
{"title":"吉隆坡医院常规核医学实践中残留[99mTc]Tc-Tetrofosmin活性的评估","authors":"Ren Yi Fong, Nurul Maisara Jaffar, Rachel Jen Lyn Chung, Hui Ling Tong, Syifaa' Aminudin, Kee Wei Lau","doi":"10.2967/jnmt.124.268886","DOIUrl":null,"url":null,"abstract":"<p><p>Myocardial perfusion imaging using the radiopharmaceutical [<sup>99m</sup>Tc]Tc-tetrofosmin plays a crucial role in diagnosing cardiac conditions. However, variations in the residual activity of [<sup>99m</sup>Tc]Tc-tetrofosmin in plastic syringes after administration may impact imaging quality and patient safety. This study aimed to evaluate the residual activity of [<sup>99m</sup>Tc]Tc-tetrofosmin in plastic syringes after administration during routine nuclear medicine procedures at Hospital Kuala Lumpur, assessing compliance with department protocols and variability among different syringe brands. <b>Methods:</b> A single-center prospective observational study was conducted using stratified quota sampling, encompassing 396 samples across 3 syringe brands (SJ, BD, and Ciringe). Residual activity was measured immediately after administration, and statistical analysis was performed to compare brands and assess compliance with the department dosage protocol range of 333-555 MBq. <b>Results:</b> All injected activities aligned with the department protocol dose, with a mean effective activity of 451.23 ± 30.73 MBq and a mean residual activity of 12.63% ± 4.73%. However, variability in residual activity was observed among syringe brands. BD exhibited the highest mean residual activity (16.45%), significantly differing from SJ (9.95%) and Ciringe (11.50%) (<i>P</i> < 0.001). <b>Conclusion:</b> Rigorous syringe selection is crucial in myocardial perfusion imaging procedures to minimize residual activity and ensure compliance with dosimetry standards, emphasizing the importance of integrating pharmacy practices into nuclear medicine protocols. Standardized protocols and quality assurance measures are essential to optimize imaging outcomes and prioritize patient safety. These findings highlight the importance of ongoing monitoring and interdisciplinary collaboration to navigate residual activity management effectively in routine nuclear medicine practice.</p>","PeriodicalId":16548,"journal":{"name":"Journal of nuclear medicine technology","volume":" ","pages":"57-62"},"PeriodicalIF":1.0000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of Residual [<sup>99m</sup>Tc]Tc-Tetrofosmin Activity in Routine Nuclear Medicine Practice at Hospital Kuala Lumpur.\",\"authors\":\"Ren Yi Fong, Nurul Maisara Jaffar, Rachel Jen Lyn Chung, Hui Ling Tong, Syifaa' Aminudin, Kee Wei Lau\",\"doi\":\"10.2967/jnmt.124.268886\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Myocardial perfusion imaging using the radiopharmaceutical [<sup>99m</sup>Tc]Tc-tetrofosmin plays a crucial role in diagnosing cardiac conditions. However, variations in the residual activity of [<sup>99m</sup>Tc]Tc-tetrofosmin in plastic syringes after administration may impact imaging quality and patient safety. This study aimed to evaluate the residual activity of [<sup>99m</sup>Tc]Tc-tetrofosmin in plastic syringes after administration during routine nuclear medicine procedures at Hospital Kuala Lumpur, assessing compliance with department protocols and variability among different syringe brands. <b>Methods:</b> A single-center prospective observational study was conducted using stratified quota sampling, encompassing 396 samples across 3 syringe brands (SJ, BD, and Ciringe). Residual activity was measured immediately after administration, and statistical analysis was performed to compare brands and assess compliance with the department dosage protocol range of 333-555 MBq. <b>Results:</b> All injected activities aligned with the department protocol dose, with a mean effective activity of 451.23 ± 30.73 MBq and a mean residual activity of 12.63% ± 4.73%. However, variability in residual activity was observed among syringe brands. BD exhibited the highest mean residual activity (16.45%), significantly differing from SJ (9.95%) and Ciringe (11.50%) (<i>P</i> < 0.001). <b>Conclusion:</b> Rigorous syringe selection is crucial in myocardial perfusion imaging procedures to minimize residual activity and ensure compliance with dosimetry standards, emphasizing the importance of integrating pharmacy practices into nuclear medicine protocols. Standardized protocols and quality assurance measures are essential to optimize imaging outcomes and prioritize patient safety. These findings highlight the importance of ongoing monitoring and interdisciplinary collaboration to navigate residual activity management effectively in routine nuclear medicine practice.</p>\",\"PeriodicalId\":16548,\"journal\":{\"name\":\"Journal of nuclear medicine technology\",\"volume\":\" \",\"pages\":\"57-62\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of nuclear medicine technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2967/jnmt.124.268886\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nuclear medicine technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnmt.124.268886","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

使用放射性药物[99mTc]Tc-tetrofosmin进行心肌灌注成像在诊断心脏疾病中起着至关重要的作用。然而,给药后塑料注射器中[99mTc] tc -四氟氰胺残留活性的变化可能会影响成像质量和患者安全。本研究旨在评估吉隆坡医院常规核医学程序给药后塑料注射器中[99mTc] tc -四氟氰胺的残留活性,评估科室协议的依从性和不同注射器品牌的差异。方法:采用分层配额抽样方法进行单中心前瞻性观察研究,包括3个注射器品牌(SJ、BD和Ciringe)的396个样本。给药后立即测量残留活性,并进行统计分析以比较品牌并评估对部门剂量方案范围333-555 MBq的依从性。结果:所有注射活性均符合科室方案剂量,平均有效活性为451.23±30.73 MBq,平均残留活性为12.63%±4.73%。然而,在剩余活动的可变性是观察到注射器品牌。BD的平均残留活性最高(16.45%),显著高于SJ(9.95%)和Ciringe (11.50%) (P < 0.001)。结论:严格的注射器选择在心肌灌注成像过程中至关重要,以尽量减少残留活性并确保符合剂量学标准,强调将药学实践纳入核医学方案的重要性。标准化方案和质量保证措施对于优化成像结果和优先考虑患者安全至关重要。这些发现突出了持续监测和跨学科合作在常规核医学实践中有效引导残留活性管理的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of Residual [99mTc]Tc-Tetrofosmin Activity in Routine Nuclear Medicine Practice at Hospital Kuala Lumpur.

Myocardial perfusion imaging using the radiopharmaceutical [99mTc]Tc-tetrofosmin plays a crucial role in diagnosing cardiac conditions. However, variations in the residual activity of [99mTc]Tc-tetrofosmin in plastic syringes after administration may impact imaging quality and patient safety. This study aimed to evaluate the residual activity of [99mTc]Tc-tetrofosmin in plastic syringes after administration during routine nuclear medicine procedures at Hospital Kuala Lumpur, assessing compliance with department protocols and variability among different syringe brands. Methods: A single-center prospective observational study was conducted using stratified quota sampling, encompassing 396 samples across 3 syringe brands (SJ, BD, and Ciringe). Residual activity was measured immediately after administration, and statistical analysis was performed to compare brands and assess compliance with the department dosage protocol range of 333-555 MBq. Results: All injected activities aligned with the department protocol dose, with a mean effective activity of 451.23 ± 30.73 MBq and a mean residual activity of 12.63% ± 4.73%. However, variability in residual activity was observed among syringe brands. BD exhibited the highest mean residual activity (16.45%), significantly differing from SJ (9.95%) and Ciringe (11.50%) (P < 0.001). Conclusion: Rigorous syringe selection is crucial in myocardial perfusion imaging procedures to minimize residual activity and ensure compliance with dosimetry standards, emphasizing the importance of integrating pharmacy practices into nuclear medicine protocols. Standardized protocols and quality assurance measures are essential to optimize imaging outcomes and prioritize patient safety. These findings highlight the importance of ongoing monitoring and interdisciplinary collaboration to navigate residual activity management effectively in routine nuclear medicine practice.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of nuclear medicine technology
Journal of nuclear medicine technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.90
自引率
15.40%
发文量
57
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信