评估金属加工暴露对呼吸系统健康的影响:分量呼出一氧化氮水平的作用。

IF 1.3 4区 医学 Q3 ALLERGY
Journal of Asthma Pub Date : 2025-07-01 Epub Date: 2025-02-13 DOI:10.1080/02770903.2025.2463966
Hülya Doğan Tiryaki, Halim İşsever, Osman Küçükkelepçe, Adil Can Güngen, Nefise Şeker, Osman Kurt
{"title":"评估金属加工暴露对呼吸系统健康的影响:分量呼出一氧化氮水平的作用。","authors":"Hülya Doğan Tiryaki, Halim İşsever, Osman Küçükkelepçe, Adil Can Güngen, Nefise Şeker, Osman Kurt","doi":"10.1080/02770903.2025.2463966","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The significance of measuring Fractional Exhaled Nitric Oxide (FeNO) has grown, particularly in monitoring respiratory diseases like asthma. FeNO levels indicate inflammation and a rise in response to respiratory irritants. This study investigates whether repeated exposure to irritants in metal casting and coating leads to respiratory inflammation and assesses the benefits of including FeNO measurement in periodic occupational health screenings.</p><p><strong>Methods: </strong>This cross-sectional study involved 99 workers aged 18-65 in the foundry and metal coating sectors in the İkitelli Organized Industrial Zone. The study group included 54 workers exposed to metal dust and fumes, while the control group comprised 45 workers in non-exposure roles (e.g. secretarial, assembly, packaging). Data were collected through face-to-face interviews, recording demographics, smoking habits, symptoms. FeNO levels were measured and analyzed with pulmonary function test parameters.</p><p><strong>Results: </strong>FeNO levels were significantly higher in the study group compared to the control group (<i>p</i> = 0.02). No significant relationships were found between FeNO levels and age, height, weight, BMI, waist circumference, years of work, or symptom presence, but a significant negative correlation was observed between FeNO levels and FEV1/FVC. Additionally, current smokers had significantly lower FeNO levels compared to those who had quit or never smoked (study, <i>p</i> = 0.014; control, <i>p</i> = 0.011).</p><p><strong>Conclusions: </strong>Monitoring FeNO levels in occupational health assessments may facilitate early intervention and preventive measures, protecting worker health. Incorporating FeNO measurement into periodic screenings could enhance occupational health practices.</p>","PeriodicalId":15076,"journal":{"name":"Journal of Asthma","volume":" ","pages":"1148-1155"},"PeriodicalIF":1.3000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessing the impact of metalworking exposures on respiratory health: the role of fractional exhaled nitric oxide levels.\",\"authors\":\"Hülya Doğan Tiryaki, Halim İşsever, Osman Küçükkelepçe, Adil Can Güngen, Nefise Şeker, Osman Kurt\",\"doi\":\"10.1080/02770903.2025.2463966\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The significance of measuring Fractional Exhaled Nitric Oxide (FeNO) has grown, particularly in monitoring respiratory diseases like asthma. FeNO levels indicate inflammation and a rise in response to respiratory irritants. This study investigates whether repeated exposure to irritants in metal casting and coating leads to respiratory inflammation and assesses the benefits of including FeNO measurement in periodic occupational health screenings.</p><p><strong>Methods: </strong>This cross-sectional study involved 99 workers aged 18-65 in the foundry and metal coating sectors in the İkitelli Organized Industrial Zone. The study group included 54 workers exposed to metal dust and fumes, while the control group comprised 45 workers in non-exposure roles (e.g. secretarial, assembly, packaging). Data were collected through face-to-face interviews, recording demographics, smoking habits, symptoms. FeNO levels were measured and analyzed with pulmonary function test parameters.</p><p><strong>Results: </strong>FeNO levels were significantly higher in the study group compared to the control group (<i>p</i> = 0.02). No significant relationships were found between FeNO levels and age, height, weight, BMI, waist circumference, years of work, or symptom presence, but a significant negative correlation was observed between FeNO levels and FEV1/FVC. Additionally, current smokers had significantly lower FeNO levels compared to those who had quit or never smoked (study, <i>p</i> = 0.014; control, <i>p</i> = 0.011).</p><p><strong>Conclusions: </strong>Monitoring FeNO levels in occupational health assessments may facilitate early intervention and preventive measures, protecting worker health. Incorporating FeNO measurement into periodic screenings could enhance occupational health practices.</p>\",\"PeriodicalId\":15076,\"journal\":{\"name\":\"Journal of Asthma\",\"volume\":\" \",\"pages\":\"1148-1155\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Asthma\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/02770903.2025.2463966\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ALLERGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Asthma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02770903.2025.2463966","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ALLERGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:测量呼出一氧化氮分数(FeNO)的意义越来越大,特别是在监测哮喘等呼吸系统疾病方面。FeNO水平表明炎症和对呼吸道刺激物的反应上升。本研究调查了反复暴露于金属铸件和涂层中的刺激物是否会导致呼吸道炎症,并评估了在定期职业健康筛查中包括FeNO测量的好处。方法:本横断面研究涉及99名18-65岁的工人在铸造和金属涂层部门İkitelli有组织的工业区。研究小组包括54名接触金属粉尘和烟雾的工人,而对照组包括45名非接触角色的工人(例如秘书,装配,包装)。通过面对面访谈收集数据,记录人口统计,吸烟习惯,症状。用肺功能试验参数测定并分析FeNO水平。结果:研究组FeNO水平明显高于对照组(p = 0.02)。FeNO水平与年龄、身高、体重、BMI、腰围、工作年限或症状存在无显著相关性,但FeNO水平与FEV1/FVC呈显著负相关。此外,与戒烟或从不吸烟的人相比,当前吸烟者的FeNO水平显著降低(研究,p = 0.014;对照组,p = 0.011)。结论:在职业健康评估中监测FeNO水平有助于早期干预和预防措施,保护劳动者健康。将FeNO测量纳入定期筛查可以加强职业健康实践。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessing the impact of metalworking exposures on respiratory health: the role of fractional exhaled nitric oxide levels.

Objective: The significance of measuring Fractional Exhaled Nitric Oxide (FeNO) has grown, particularly in monitoring respiratory diseases like asthma. FeNO levels indicate inflammation and a rise in response to respiratory irritants. This study investigates whether repeated exposure to irritants in metal casting and coating leads to respiratory inflammation and assesses the benefits of including FeNO measurement in periodic occupational health screenings.

Methods: This cross-sectional study involved 99 workers aged 18-65 in the foundry and metal coating sectors in the İkitelli Organized Industrial Zone. The study group included 54 workers exposed to metal dust and fumes, while the control group comprised 45 workers in non-exposure roles (e.g. secretarial, assembly, packaging). Data were collected through face-to-face interviews, recording demographics, smoking habits, symptoms. FeNO levels were measured and analyzed with pulmonary function test parameters.

Results: FeNO levels were significantly higher in the study group compared to the control group (p = 0.02). No significant relationships were found between FeNO levels and age, height, weight, BMI, waist circumference, years of work, or symptom presence, but a significant negative correlation was observed between FeNO levels and FEV1/FVC. Additionally, current smokers had significantly lower FeNO levels compared to those who had quit or never smoked (study, p = 0.014; control, p = 0.011).

Conclusions: Monitoring FeNO levels in occupational health assessments may facilitate early intervention and preventive measures, protecting worker health. Incorporating FeNO measurement into periodic screenings could enhance occupational health practices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Asthma
Journal of Asthma 医学-过敏
CiteScore
4.00
自引率
5.30%
发文量
158
审稿时长
3-8 weeks
期刊介绍: Providing an authoritative open forum on asthma and related conditions, Journal of Asthma publishes clinical research around such topics as asthma management, critical and long-term care, preventative measures, environmental counselling, and patient education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信