Konrad Rykaczewski, Ankit Joshi, Shri H Viswanathan, Emily Parkerson, Mahima Gupta, Michael Park, Isabella DeClair, Kambiz Sadeghi, Sylwester Wereski, Gokul Pathikonda, Jennifer K Vanos, Ariane Middel
{"title":"使用双筒风速计和辐照度计进行先进的人体热暴露传感:引入 CARla。","authors":"Konrad Rykaczewski, Ankit Joshi, Shri H Viswanathan, Emily Parkerson, Mahima Gupta, Michael Park, Isabella DeClair, Kambiz Sadeghi, Sylwester Wereski, Gokul Pathikonda, Jennifer K Vanos, Ariane Middel","doi":"10.1007/s00484-025-02860-4","DOIUrl":null,"url":null,"abstract":"<p><p>The negative health impacts of extreme heat exposure can be mitigated by incorporating hyperlocal biometeorological observations into heat action planning, emergency responses, and heat-reducing urban design. A significant portion of outdoor human heat exposure is radiative, but it is often overlooked due to the absence of affordable, accurate, and user-friendly sensors. We developed a two cylinder anemometer and radiometer (CARla) consisting of unheated and heated gray components, which quantifies wind speed and the total radiation absorbed by the human body. The spectral properties of the gray coating match the standard short- and longwave absorptivity used in mean radiant temperature (MRT) calculations. We optimized the geometrical parameters of the cylinders, including height, wall thickness, and side-mounting, to minimize errors in MRT and wind speed measurements. Experiments were conducted across 15 outdoor sites in Tempe, Arizona, during the record-setting heat wave from August to October 2024. Results demonstrated that the MRT measured using CARla closely matched those measured using 3-way net radiometers. The average error in MRT using the new compact system was 1.3 ± 2.2 °C across a wide MRT range (20 to 75 °C). CARLa represents a significant improvement compared to other low-cost radiometers. The average difference between the CARla and ultrasonic anemometers for wind speed was - 0.05 ± 0.36 m·s<sup>-1</sup> in the 0.25 to 3 m·s<sup>-1</sup> range, comparable to standard low-cost anemometers. We integrated the CARla sensor with an Arduino-based logger, creating a cost-effective and accurate tool for broadly characterizing human exposure to extreme heat.</p>","PeriodicalId":588,"journal":{"name":"International Journal of Biometeorology","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advanced human heat exposure sensing using two cylinder anemometer and radiometer: introducing CARla.\",\"authors\":\"Konrad Rykaczewski, Ankit Joshi, Shri H Viswanathan, Emily Parkerson, Mahima Gupta, Michael Park, Isabella DeClair, Kambiz Sadeghi, Sylwester Wereski, Gokul Pathikonda, Jennifer K Vanos, Ariane Middel\",\"doi\":\"10.1007/s00484-025-02860-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The negative health impacts of extreme heat exposure can be mitigated by incorporating hyperlocal biometeorological observations into heat action planning, emergency responses, and heat-reducing urban design. A significant portion of outdoor human heat exposure is radiative, but it is often overlooked due to the absence of affordable, accurate, and user-friendly sensors. We developed a two cylinder anemometer and radiometer (CARla) consisting of unheated and heated gray components, which quantifies wind speed and the total radiation absorbed by the human body. The spectral properties of the gray coating match the standard short- and longwave absorptivity used in mean radiant temperature (MRT) calculations. We optimized the geometrical parameters of the cylinders, including height, wall thickness, and side-mounting, to minimize errors in MRT and wind speed measurements. Experiments were conducted across 15 outdoor sites in Tempe, Arizona, during the record-setting heat wave from August to October 2024. Results demonstrated that the MRT measured using CARla closely matched those measured using 3-way net radiometers. The average error in MRT using the new compact system was 1.3 ± 2.2 °C across a wide MRT range (20 to 75 °C). CARLa represents a significant improvement compared to other low-cost radiometers. The average difference between the CARla and ultrasonic anemometers for wind speed was - 0.05 ± 0.36 m·s<sup>-1</sup> in the 0.25 to 3 m·s<sup>-1</sup> range, comparable to standard low-cost anemometers. We integrated the CARla sensor with an Arduino-based logger, creating a cost-effective and accurate tool for broadly characterizing human exposure to extreme heat.</p>\",\"PeriodicalId\":588,\"journal\":{\"name\":\"International Journal of Biometeorology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-02-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Biometeorology\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1007/s00484-025-02860-4\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biometeorology","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1007/s00484-025-02860-4","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
Advanced human heat exposure sensing using two cylinder anemometer and radiometer: introducing CARla.
The negative health impacts of extreme heat exposure can be mitigated by incorporating hyperlocal biometeorological observations into heat action planning, emergency responses, and heat-reducing urban design. A significant portion of outdoor human heat exposure is radiative, but it is often overlooked due to the absence of affordable, accurate, and user-friendly sensors. We developed a two cylinder anemometer and radiometer (CARla) consisting of unheated and heated gray components, which quantifies wind speed and the total radiation absorbed by the human body. The spectral properties of the gray coating match the standard short- and longwave absorptivity used in mean radiant temperature (MRT) calculations. We optimized the geometrical parameters of the cylinders, including height, wall thickness, and side-mounting, to minimize errors in MRT and wind speed measurements. Experiments were conducted across 15 outdoor sites in Tempe, Arizona, during the record-setting heat wave from August to October 2024. Results demonstrated that the MRT measured using CARla closely matched those measured using 3-way net radiometers. The average error in MRT using the new compact system was 1.3 ± 2.2 °C across a wide MRT range (20 to 75 °C). CARLa represents a significant improvement compared to other low-cost radiometers. The average difference between the CARla and ultrasonic anemometers for wind speed was - 0.05 ± 0.36 m·s-1 in the 0.25 to 3 m·s-1 range, comparable to standard low-cost anemometers. We integrated the CARla sensor with an Arduino-based logger, creating a cost-effective and accurate tool for broadly characterizing human exposure to extreme heat.
期刊介绍:
The Journal publishes original research papers, review articles and short communications on studies examining the interactions between living organisms and factors of the natural and artificial atmospheric environment.
Living organisms extend from single cell organisms, to plants and animals, including humans. The atmospheric environment includes climate and weather, electromagnetic radiation, and chemical and biological pollutants. The journal embraces basic and applied research and practical aspects such as living conditions, agriculture, forestry, and health.
The journal is published for the International Society of Biometeorology, and most membership categories include a subscription to the Journal.