在无骨水泥全髋关节置换术中,高偏置柄设计不会增加全负重下的柄移位:基于模型的 RSA 研究。

IF 2.3 4区 医学 Q2 ORTHOPEDICS
Tobias Reiner, Robert Sonntag, Jan Philippe Kretzer, Michael Clarius, Eike Jakubowitz, Stefan Weiss, Stefan Kinkel, Tilman Walker, Tobias Gotterbarm, Timo Albert Nees
{"title":"在无骨水泥全髋关节置换术中,高偏置柄设计不会增加全负重下的柄移位:基于模型的 RSA 研究。","authors":"Tobias Reiner, Robert Sonntag, Jan Philippe Kretzer, Michael Clarius, Eike Jakubowitz, Stefan Weiss, Stefan Kinkel, Tilman Walker, Tobias Gotterbarm, Timo Albert Nees","doi":"10.1186/s42836-024-00290-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>High-offset stems in cementless primary total hip arthroplasty (THA) have been potentially associated with early aseptic femoral loosening. This study aimed to evaluate the primary and secondary stability of a cementless high-offset femoral component under full weight-bearing conditions using model-based RSA, comparing it with a standard offset stem in patients undergoing THA.</p><p><strong>Methods: </strong>In this prospective, observational, single-center study, 42 patients with end-stage hip osteoarthritis underwent cementless primary THA using either a standard (SL-PLUS Standard) or a high-offset (SL-PLUS Lateral) cementless stem. Radiostereometric analysis (RSA) was employed to monitor stem migration at six weeks and three, six, twelve, and twenty-four months. Clinical outcomes were assessed using the modified Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).</p><p><strong>Results: </strong>There were no significant differences in mean stem subsidence between the groups at any follow-up interval, indicating comparable primary and secondary stability. After minimal initial subsidence (SL-PLUS Standard: up to -0.54 mm; SL-PLUS Lateral: up to -0.73 mm), no further progressive migration was observed. A significant difference in stem anteversion was noted between the groups at six months (P = 0.021) and two years (P = 0.001). The SL-PLUS Lateral group had significantly better WOMAC scores at the two-year follow-up (P = 0.027).</p><p><strong>Conclusions: </strong>This RSA study demonstrated similar migration patterns for the high-offset and standard-offset cementless stems within the first two years after operation. Both groups exhibited initial subsidence followed by high secondary stability. Based on the results of this study, the SL-PLUS Lateral is a safe alternative for patients with high femoral offset undergoing cementless THA.</p>","PeriodicalId":52831,"journal":{"name":"Arthroplasty","volume":"7 1","pages":"7"},"PeriodicalIF":2.3000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11792696/pdf/","citationCount":"0","resultStr":"{\"title\":\"A high offset stem design does not increase stem migration under full weight bearing in cementless total hip arthroplasty: a model-based RSA study.\",\"authors\":\"Tobias Reiner, Robert Sonntag, Jan Philippe Kretzer, Michael Clarius, Eike Jakubowitz, Stefan Weiss, Stefan Kinkel, Tilman Walker, Tobias Gotterbarm, Timo Albert Nees\",\"doi\":\"10.1186/s42836-024-00290-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>High-offset stems in cementless primary total hip arthroplasty (THA) have been potentially associated with early aseptic femoral loosening. This study aimed to evaluate the primary and secondary stability of a cementless high-offset femoral component under full weight-bearing conditions using model-based RSA, comparing it with a standard offset stem in patients undergoing THA.</p><p><strong>Methods: </strong>In this prospective, observational, single-center study, 42 patients with end-stage hip osteoarthritis underwent cementless primary THA using either a standard (SL-PLUS Standard) or a high-offset (SL-PLUS Lateral) cementless stem. Radiostereometric analysis (RSA) was employed to monitor stem migration at six weeks and three, six, twelve, and twenty-four months. Clinical outcomes were assessed using the modified Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).</p><p><strong>Results: </strong>There were no significant differences in mean stem subsidence between the groups at any follow-up interval, indicating comparable primary and secondary stability. After minimal initial subsidence (SL-PLUS Standard: up to -0.54 mm; SL-PLUS Lateral: up to -0.73 mm), no further progressive migration was observed. A significant difference in stem anteversion was noted between the groups at six months (P = 0.021) and two years (P = 0.001). The SL-PLUS Lateral group had significantly better WOMAC scores at the two-year follow-up (P = 0.027).</p><p><strong>Conclusions: </strong>This RSA study demonstrated similar migration patterns for the high-offset and standard-offset cementless stems within the first two years after operation. Both groups exhibited initial subsidence followed by high secondary stability. Based on the results of this study, the SL-PLUS Lateral is a safe alternative for patients with high femoral offset undergoing cementless THA.</p>\",\"PeriodicalId\":52831,\"journal\":{\"name\":\"Arthroplasty\",\"volume\":\"7 1\",\"pages\":\"7\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-02-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11792696/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arthroplasty\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s42836-024-00290-y\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-024-00290-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
A high offset stem design does not increase stem migration under full weight bearing in cementless total hip arthroplasty: a model-based RSA study.

Background: High-offset stems in cementless primary total hip arthroplasty (THA) have been potentially associated with early aseptic femoral loosening. This study aimed to evaluate the primary and secondary stability of a cementless high-offset femoral component under full weight-bearing conditions using model-based RSA, comparing it with a standard offset stem in patients undergoing THA.

Methods: In this prospective, observational, single-center study, 42 patients with end-stage hip osteoarthritis underwent cementless primary THA using either a standard (SL-PLUS Standard) or a high-offset (SL-PLUS Lateral) cementless stem. Radiostereometric analysis (RSA) was employed to monitor stem migration at six weeks and three, six, twelve, and twenty-four months. Clinical outcomes were assessed using the modified Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).

Results: There were no significant differences in mean stem subsidence between the groups at any follow-up interval, indicating comparable primary and secondary stability. After minimal initial subsidence (SL-PLUS Standard: up to -0.54 mm; SL-PLUS Lateral: up to -0.73 mm), no further progressive migration was observed. A significant difference in stem anteversion was noted between the groups at six months (P = 0.021) and two years (P = 0.001). The SL-PLUS Lateral group had significantly better WOMAC scores at the two-year follow-up (P = 0.027).

Conclusions: This RSA study demonstrated similar migration patterns for the high-offset and standard-offset cementless stems within the first two years after operation. Both groups exhibited initial subsidence followed by high secondary stability. Based on the results of this study, the SL-PLUS Lateral is a safe alternative for patients with high femoral offset undergoing cementless THA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Arthroplasty
Arthroplasty ORTHOPEDICS-
CiteScore
2.20
自引率
0.00%
发文量
49
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信