Tobias Reiner, Robert Sonntag, Jan Philippe Kretzer, Michael Clarius, Eike Jakubowitz, Stefan Weiss, Stefan Kinkel, Tilman Walker, Tobias Gotterbarm, Timo Albert Nees
{"title":"在无骨水泥全髋关节置换术中,高偏置柄设计不会增加全负重下的柄移位:基于模型的 RSA 研究。","authors":"Tobias Reiner, Robert Sonntag, Jan Philippe Kretzer, Michael Clarius, Eike Jakubowitz, Stefan Weiss, Stefan Kinkel, Tilman Walker, Tobias Gotterbarm, Timo Albert Nees","doi":"10.1186/s42836-024-00290-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>High-offset stems in cementless primary total hip arthroplasty (THA) have been potentially associated with early aseptic femoral loosening. This study aimed to evaluate the primary and secondary stability of a cementless high-offset femoral component under full weight-bearing conditions using model-based RSA, comparing it with a standard offset stem in patients undergoing THA.</p><p><strong>Methods: </strong>In this prospective, observational, single-center study, 42 patients with end-stage hip osteoarthritis underwent cementless primary THA using either a standard (SL-PLUS Standard) or a high-offset (SL-PLUS Lateral) cementless stem. Radiostereometric analysis (RSA) was employed to monitor stem migration at six weeks and three, six, twelve, and twenty-four months. Clinical outcomes were assessed using the modified Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).</p><p><strong>Results: </strong>There were no significant differences in mean stem subsidence between the groups at any follow-up interval, indicating comparable primary and secondary stability. After minimal initial subsidence (SL-PLUS Standard: up to -0.54 mm; SL-PLUS Lateral: up to -0.73 mm), no further progressive migration was observed. A significant difference in stem anteversion was noted between the groups at six months (P = 0.021) and two years (P = 0.001). The SL-PLUS Lateral group had significantly better WOMAC scores at the two-year follow-up (P = 0.027).</p><p><strong>Conclusions: </strong>This RSA study demonstrated similar migration patterns for the high-offset and standard-offset cementless stems within the first two years after operation. Both groups exhibited initial subsidence followed by high secondary stability. Based on the results of this study, the SL-PLUS Lateral is a safe alternative for patients with high femoral offset undergoing cementless THA.</p>","PeriodicalId":52831,"journal":{"name":"Arthroplasty","volume":"7 1","pages":"7"},"PeriodicalIF":2.3000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11792696/pdf/","citationCount":"0","resultStr":"{\"title\":\"A high offset stem design does not increase stem migration under full weight bearing in cementless total hip arthroplasty: a model-based RSA study.\",\"authors\":\"Tobias Reiner, Robert Sonntag, Jan Philippe Kretzer, Michael Clarius, Eike Jakubowitz, Stefan Weiss, Stefan Kinkel, Tilman Walker, Tobias Gotterbarm, Timo Albert Nees\",\"doi\":\"10.1186/s42836-024-00290-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>High-offset stems in cementless primary total hip arthroplasty (THA) have been potentially associated with early aseptic femoral loosening. This study aimed to evaluate the primary and secondary stability of a cementless high-offset femoral component under full weight-bearing conditions using model-based RSA, comparing it with a standard offset stem in patients undergoing THA.</p><p><strong>Methods: </strong>In this prospective, observational, single-center study, 42 patients with end-stage hip osteoarthritis underwent cementless primary THA using either a standard (SL-PLUS Standard) or a high-offset (SL-PLUS Lateral) cementless stem. Radiostereometric analysis (RSA) was employed to monitor stem migration at six weeks and three, six, twelve, and twenty-four months. Clinical outcomes were assessed using the modified Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).</p><p><strong>Results: </strong>There were no significant differences in mean stem subsidence between the groups at any follow-up interval, indicating comparable primary and secondary stability. After minimal initial subsidence (SL-PLUS Standard: up to -0.54 mm; SL-PLUS Lateral: up to -0.73 mm), no further progressive migration was observed. A significant difference in stem anteversion was noted between the groups at six months (P = 0.021) and two years (P = 0.001). The SL-PLUS Lateral group had significantly better WOMAC scores at the two-year follow-up (P = 0.027).</p><p><strong>Conclusions: </strong>This RSA study demonstrated similar migration patterns for the high-offset and standard-offset cementless stems within the first two years after operation. Both groups exhibited initial subsidence followed by high secondary stability. Based on the results of this study, the SL-PLUS Lateral is a safe alternative for patients with high femoral offset undergoing cementless THA.</p>\",\"PeriodicalId\":52831,\"journal\":{\"name\":\"Arthroplasty\",\"volume\":\"7 1\",\"pages\":\"7\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-02-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11792696/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arthroplasty\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s42836-024-00290-y\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-024-00290-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
A high offset stem design does not increase stem migration under full weight bearing in cementless total hip arthroplasty: a model-based RSA study.
Background: High-offset stems in cementless primary total hip arthroplasty (THA) have been potentially associated with early aseptic femoral loosening. This study aimed to evaluate the primary and secondary stability of a cementless high-offset femoral component under full weight-bearing conditions using model-based RSA, comparing it with a standard offset stem in patients undergoing THA.
Methods: In this prospective, observational, single-center study, 42 patients with end-stage hip osteoarthritis underwent cementless primary THA using either a standard (SL-PLUS Standard) or a high-offset (SL-PLUS Lateral) cementless stem. Radiostereometric analysis (RSA) was employed to monitor stem migration at six weeks and three, six, twelve, and twenty-four months. Clinical outcomes were assessed using the modified Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).
Results: There were no significant differences in mean stem subsidence between the groups at any follow-up interval, indicating comparable primary and secondary stability. After minimal initial subsidence (SL-PLUS Standard: up to -0.54 mm; SL-PLUS Lateral: up to -0.73 mm), no further progressive migration was observed. A significant difference in stem anteversion was noted between the groups at six months (P = 0.021) and two years (P = 0.001). The SL-PLUS Lateral group had significantly better WOMAC scores at the two-year follow-up (P = 0.027).
Conclusions: This RSA study demonstrated similar migration patterns for the high-offset and standard-offset cementless stems within the first two years after operation. Both groups exhibited initial subsidence followed by high secondary stability. Based on the results of this study, the SL-PLUS Lateral is a safe alternative for patients with high femoral offset undergoing cementless THA.