术前变量对活体延长焦深人工晶状体术后3个月功能结局的影响:前瞻性病例系列

IF 4.1 1区 医学 Q1 OPHTHALMOLOGY
Giacomo Savini, Alice Galzignato, Catarina P Coutinho, Jinhai Huang, Yue Wu, Piero Barboni, João Mendanha Dias, Filomena J Ribeiro, Domenico Schiano-Lomoriello
{"title":"术前变量对活体延长焦深人工晶状体术后3个月功能结局的影响:前瞻性病例系列","authors":"Giacomo Savini, Alice Galzignato, Catarina P Coutinho, Jinhai Huang, Yue Wu, Piero Barboni, João Mendanha Dias, Filomena J Ribeiro, Domenico Schiano-Lomoriello","doi":"10.1186/s40662-024-00424-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To investigate the functional results of the AcrySof IQ Vivity (Alcon, Fort Worth, TX) extended depth-of-focus intraocular lens (EDoF-IOL) and explore correlations between the preoperative biometric parameters and the postoperative functional outcomes.</p><p><strong>Methods: </strong>In a prospective, single-center, non-randomized study, axial length, keratometry, anterior chamber depth, scotopic and photopic pupil diameters, pupil decentration, corneal asphericity, corneal higher-order aberrations (HOAs), coma and spherical aberration were measured preoperatively. The EDoF-IOL was implanted bilaterally. Three months postoperatively, manifest refraction, monocular and binocular uncorrected and corrected visual acuity at 4 m, 66 cm and 40 cm, binocular defocus curve, binocular contrast sensitivity, halometry and Strehl ratio were measured. Visual disturbances and spectacle independence were assessed with McAlinden and IOLSAT questionnaires, respectively. Assuming a minimum Pearson r correlation coefficient between variables of 0.5 with a power of 80% and a P value less than 0.05, a minimum sample size of 29 (58 eyes) cases was required.</p><p><strong>Results: </strong>Forty-three patients were enrolled. Binocular distance corrected visual acuity was lower than 0.1 logMAR for a defocus between + 1.0 and - 1.5 D. The mean values at 66 cm and 40 cm were - 0.07 ± 0.06 and 0.19 ± 0.13 logMAR, respectively. McAlinden's questionnaire revealed mean scores close to zero for all questions. The IOLSAT questionnaire showed that spectacles were never used for distance and intermediate vision. Regression analysis did not disclose any significant correlation between the preoperatively measured variables and the postoperative outcomes, with a few exceptions: preoperative higher order corneal aberrations were correlated to halometry area (r<sup>2</sup> = 0.2592, P = 0.0006) and the Q value to contrast sensitivity (r<sup>2</sup> = 0.1717, P = 0.00574) under photopic conditions with glare at a spatial frequency of 18 cpd and without glare for all spatial frequencies (P < 0.01); it was also correlated to contrast sensitivity under mesopic conditions without glare at a spatial frequency of 12 cpd (r<sup>2</sup> = 0.2311, P = 0.0011).</p><p><strong>Conclusions: </strong>In healthy unoperated eyes, the visual outcomes for this EDoF-IOL are independent of most of the patients' preoperative parameters. Attention should be paid to preoperative corneal aberrations and asphericity, which did not lead to visual disturbances, but may be potential sources of halo and reduced contrast sensitivity.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"12 1","pages":"8"},"PeriodicalIF":4.1000,"publicationDate":"2025-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11787752/pdf/","citationCount":"0","resultStr":"{\"title\":\"Influence of preoperative variables on the 3-month functional outcomes of the Vivity extended depth-of-focus intraocular lens: a prospective case series.\",\"authors\":\"Giacomo Savini, Alice Galzignato, Catarina P Coutinho, Jinhai Huang, Yue Wu, Piero Barboni, João Mendanha Dias, Filomena J Ribeiro, Domenico Schiano-Lomoriello\",\"doi\":\"10.1186/s40662-024-00424-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To investigate the functional results of the AcrySof IQ Vivity (Alcon, Fort Worth, TX) extended depth-of-focus intraocular lens (EDoF-IOL) and explore correlations between the preoperative biometric parameters and the postoperative functional outcomes.</p><p><strong>Methods: </strong>In a prospective, single-center, non-randomized study, axial length, keratometry, anterior chamber depth, scotopic and photopic pupil diameters, pupil decentration, corneal asphericity, corneal higher-order aberrations (HOAs), coma and spherical aberration were measured preoperatively. The EDoF-IOL was implanted bilaterally. Three months postoperatively, manifest refraction, monocular and binocular uncorrected and corrected visual acuity at 4 m, 66 cm and 40 cm, binocular defocus curve, binocular contrast sensitivity, halometry and Strehl ratio were measured. Visual disturbances and spectacle independence were assessed with McAlinden and IOLSAT questionnaires, respectively. Assuming a minimum Pearson r correlation coefficient between variables of 0.5 with a power of 80% and a P value less than 0.05, a minimum sample size of 29 (58 eyes) cases was required.</p><p><strong>Results: </strong>Forty-three patients were enrolled. Binocular distance corrected visual acuity was lower than 0.1 logMAR for a defocus between + 1.0 and - 1.5 D. The mean values at 66 cm and 40 cm were - 0.07 ± 0.06 and 0.19 ± 0.13 logMAR, respectively. McAlinden's questionnaire revealed mean scores close to zero for all questions. The IOLSAT questionnaire showed that spectacles were never used for distance and intermediate vision. Regression analysis did not disclose any significant correlation between the preoperatively measured variables and the postoperative outcomes, with a few exceptions: preoperative higher order corneal aberrations were correlated to halometry area (r<sup>2</sup> = 0.2592, P = 0.0006) and the Q value to contrast sensitivity (r<sup>2</sup> = 0.1717, P = 0.00574) under photopic conditions with glare at a spatial frequency of 18 cpd and without glare for all spatial frequencies (P < 0.01); it was also correlated to contrast sensitivity under mesopic conditions without glare at a spatial frequency of 12 cpd (r<sup>2</sup> = 0.2311, P = 0.0011).</p><p><strong>Conclusions: </strong>In healthy unoperated eyes, the visual outcomes for this EDoF-IOL are independent of most of the patients' preoperative parameters. Attention should be paid to preoperative corneal aberrations and asphericity, which did not lead to visual disturbances, but may be potential sources of halo and reduced contrast sensitivity.</p>\",\"PeriodicalId\":12194,\"journal\":{\"name\":\"Eye and Vision\",\"volume\":\"12 1\",\"pages\":\"8\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2025-02-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11787752/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye and Vision\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40662-024-00424-y\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-024-00424-y","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:研究AcrySof IQ Vivity (Alcon, Fort Worth, TX)扩展焦深人工晶状体(EDoF-IOL)的功能结果,探讨术前生物特征参数与术后功能结果的相关性。方法:在一项前瞻性、单中心、非随机研究中,术前测量眼轴长、角膜测量、前房深度、暗位和光位瞳孔直径、瞳孔分散、角膜非球面度、角膜高阶像差(HOAs)、昏迷和球差。双侧植入EDoF-IOL。术后3个月,测量明显屈光、单眼、双眼未矫正视力、4 m、66 cm、40 cm矫正视力、双眼离焦曲线、双眼对比敏感度、光饱和度、Strehl比。分别用McAlinden问卷和IOLSAT问卷评估视力障碍和眼镜独立性。假设变量之间的Pearson r相关系数最小为0.5,幂为80%,P值小于0.05,则需要最小样本量为29(58眼)例。结果:纳入43例患者。离焦在+ 1.0 ~ - 1.5 d时,双眼距离矫正视力低于0.1 logMAR, 66 cm和40 cm处的平均值分别为- 0.07±0.06和0.19±0.13 logMAR。麦卡林登的问卷显示,所有问题的平均得分都接近于零。IOLSAT问卷显示,眼镜从未用于远距离和中间视力。回归分析未发现术前测量变量与术后结果之间存在显著相关性,只有少数例外:术前高阶角膜像差与光量测量面积相关(r2 = 0.2592, P = 0.0006),在空间频率为18 cpd的光条件下与所有空间频率无眩光条件下的Q值与对比敏感度相关(r2 = 0.1717, P = 0.00574) (P 2 = 0.2311, P = 0.0011)。结论:在未手术的健康眼睛中,这种EDoF-IOL的视力结果与大多数患者的术前参数无关。术前应注意角膜像差和非球形,它们不会导致视力障碍,但可能是光晕和对比度降低的潜在来源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of preoperative variables on the 3-month functional outcomes of the Vivity extended depth-of-focus intraocular lens: a prospective case series.

Background: To investigate the functional results of the AcrySof IQ Vivity (Alcon, Fort Worth, TX) extended depth-of-focus intraocular lens (EDoF-IOL) and explore correlations between the preoperative biometric parameters and the postoperative functional outcomes.

Methods: In a prospective, single-center, non-randomized study, axial length, keratometry, anterior chamber depth, scotopic and photopic pupil diameters, pupil decentration, corneal asphericity, corneal higher-order aberrations (HOAs), coma and spherical aberration were measured preoperatively. The EDoF-IOL was implanted bilaterally. Three months postoperatively, manifest refraction, monocular and binocular uncorrected and corrected visual acuity at 4 m, 66 cm and 40 cm, binocular defocus curve, binocular contrast sensitivity, halometry and Strehl ratio were measured. Visual disturbances and spectacle independence were assessed with McAlinden and IOLSAT questionnaires, respectively. Assuming a minimum Pearson r correlation coefficient between variables of 0.5 with a power of 80% and a P value less than 0.05, a minimum sample size of 29 (58 eyes) cases was required.

Results: Forty-three patients were enrolled. Binocular distance corrected visual acuity was lower than 0.1 logMAR for a defocus between + 1.0 and - 1.5 D. The mean values at 66 cm and 40 cm were - 0.07 ± 0.06 and 0.19 ± 0.13 logMAR, respectively. McAlinden's questionnaire revealed mean scores close to zero for all questions. The IOLSAT questionnaire showed that spectacles were never used for distance and intermediate vision. Regression analysis did not disclose any significant correlation between the preoperatively measured variables and the postoperative outcomes, with a few exceptions: preoperative higher order corneal aberrations were correlated to halometry area (r2 = 0.2592, P = 0.0006) and the Q value to contrast sensitivity (r2 = 0.1717, P = 0.00574) under photopic conditions with glare at a spatial frequency of 18 cpd and without glare for all spatial frequencies (P < 0.01); it was also correlated to contrast sensitivity under mesopic conditions without glare at a spatial frequency of 12 cpd (r2 = 0.2311, P = 0.0011).

Conclusions: In healthy unoperated eyes, the visual outcomes for this EDoF-IOL are independent of most of the patients' preoperative parameters. Attention should be paid to preoperative corneal aberrations and asphericity, which did not lead to visual disturbances, but may be potential sources of halo and reduced contrast sensitivity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Eye and Vision
Eye and Vision OPHTHALMOLOGY-
CiteScore
8.60
自引率
2.40%
发文量
89
审稿时长
15 weeks
期刊介绍: Eye and Vision is an open access, peer-reviewed journal for ophthalmologists and visual science specialists. It welcomes research articles, reviews, methodologies, commentaries, case reports, perspectives and short reports encompassing all aspects of eye and vision. Topics of interest include but are not limited to: current developments of theoretical, experimental and clinical investigations in ophthalmology, optometry and vision science which focus on novel and high-impact findings on central issues pertaining to biology, pathophysiology and etiology of eye diseases as well as advances in diagnostic techniques, surgical treatment, instrument updates, the latest drug findings, results of clinical trials and research findings. It aims to provide ophthalmologists and visual science specialists with the latest developments in theoretical, experimental and clinical investigations in eye and vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信