全弓数字植入物印模真实性:一项体内研究

IF 5.3 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Vygandas Rutkūnas, Daniel Kuleš, Marta Revilla-León, Mykolas Akulauskas, Liudas Auškalnis, Ieva Gendvilienė
{"title":"全弓数字植入物印模真实性:一项体内研究","authors":"Vygandas Rutkūnas,&nbsp;Daniel Kuleš,&nbsp;Marta Revilla-León,&nbsp;Mykolas Akulauskas,&nbsp;Liudas Auškalnis,&nbsp;Ieva Gendvilienė","doi":"10.1111/clr.14411","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To evaluate the trueness of maxillary and mandibular full-arch implant digital impressions with and without additional reference objects.</p>\n </section>\n \n <section>\n \n <h3> Material and Methods</h3>\n \n <p>Seventeen maxillary and 6 mandibular arches with four implants were randomly divided into a group with additional reference objects (wRO group, <i>n</i> = 12) and without them (woRO group, <i>n</i> = 11) and scanned with an intraoral scanner (IOS). For each jaw, the control model (CM) data was obtained to evaluate the deviations in the scan body positions in the wRO and woRO groups. CM and IOS data sets were imported into metrology software for distance and angle measurements between scan body pairs 1–2, 1–3, and 1–4. Unsigned values of distance and angle data differences between CM and IOS groups were used for further analysis.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The highest statistically significant (<i>p &lt; 0.05</i>) differences between distance and angulation measurements of the maxilla and mandible were observed in the 1–4 scan body pair group (136 ± 95 μm, 0.95° ± 0.79°; 362 ± 233 μm, 2.22° ± 2.11°, respectively). Distance deviations of the mandible were higher in all scan body pair groups. The woRO group had higher distance and angulation unsigned trueness values than in the wRO group, especially in the 1–4 scan body pair (224 ± 183 μm, 1.77° ± 1.76°;169 ± 162 μm, and 0.83° ± 0.57°, respectively).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>IOS for the full-arch cases had statistically and clinically significant distance and angle deviations. Higher deviations were observed in the single mandibular scan body pair. The tendency of diminished distance and angular deviations with the utilization of the additional reference objects was observed, though these differences were not statistically significant.</p>\n </section>\n </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"36 5","pages":"640-649"},"PeriodicalIF":5.3000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Full-Arch Digital Implant Impression Trueness: An in Vivo Study\",\"authors\":\"Vygandas Rutkūnas,&nbsp;Daniel Kuleš,&nbsp;Marta Revilla-León,&nbsp;Mykolas Akulauskas,&nbsp;Liudas Auškalnis,&nbsp;Ieva Gendvilienė\",\"doi\":\"10.1111/clr.14411\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>To evaluate the trueness of maxillary and mandibular full-arch implant digital impressions with and without additional reference objects.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Material and Methods</h3>\\n \\n <p>Seventeen maxillary and 6 mandibular arches with four implants were randomly divided into a group with additional reference objects (wRO group, <i>n</i> = 12) and without them (woRO group, <i>n</i> = 11) and scanned with an intraoral scanner (IOS). For each jaw, the control model (CM) data was obtained to evaluate the deviations in the scan body positions in the wRO and woRO groups. CM and IOS data sets were imported into metrology software for distance and angle measurements between scan body pairs 1–2, 1–3, and 1–4. Unsigned values of distance and angle data differences between CM and IOS groups were used for further analysis.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The highest statistically significant (<i>p &lt; 0.05</i>) differences between distance and angulation measurements of the maxilla and mandible were observed in the 1–4 scan body pair group (136 ± 95 μm, 0.95° ± 0.79°; 362 ± 233 μm, 2.22° ± 2.11°, respectively). Distance deviations of the mandible were higher in all scan body pair groups. The woRO group had higher distance and angulation unsigned trueness values than in the wRO group, especially in the 1–4 scan body pair (224 ± 183 μm, 1.77° ± 1.76°;169 ± 162 μm, and 0.83° ± 0.57°, respectively).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>IOS for the full-arch cases had statistically and clinically significant distance and angle deviations. Higher deviations were observed in the single mandibular scan body pair. The tendency of diminished distance and angular deviations with the utilization of the additional reference objects was observed, though these differences were not statistically significant.</p>\\n </section>\\n </div>\",\"PeriodicalId\":10455,\"journal\":{\"name\":\"Clinical Oral Implants Research\",\"volume\":\"36 5\",\"pages\":\"640-649\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2025-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Oral Implants Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/clr.14411\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/clr.14411","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的评价上颌下颌全弓种植体数字印模的准确性。材料与方法将17个上颌弓和6个下颌骨弓随机分为有附加参考物组(wRO组,n = 12)和无附加参考物组(woRO组,n = 11),用口腔内扫描仪(IOS)扫描。对于每个颌骨,获得控制模型(CM)数据,以评估wRO组和woRO组扫描体位置的偏差。将CM和IOS数据集导入计量软件,测量扫描体对1-2、1-3和1-4之间的距离和角度。CM组和IOS组之间距离和角度数据差异的无符号值用于进一步分析。结果最高统计学意义(p <;1 ~ 4个扫描体对组上颌和下颌骨的距离和角度测量值差异为(136±95 μm, 0.95°±0.79°;362±233 μm,分别为2.22°±2.11°)。下颌骨的距离偏差在所有扫描体对组中均较高。woRO组的距离和角度无符号真实度高于wRO组,特别是在1-4扫描体对(分别为224±183 μm、1.77°±1.76°、169±162 μm和0.83°±0.57°)。结论全足弓病例的sios距离和角度偏差具有统计学和临床意义。在单个下颌骨扫描体对中观察到较高的偏差。随着额外参考对象的使用,观察到距离和角度偏差减小的趋势,尽管这些差异没有统计学意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Full-Arch Digital Implant Impression Trueness: An in Vivo Study

Objectives

To evaluate the trueness of maxillary and mandibular full-arch implant digital impressions with and without additional reference objects.

Material and Methods

Seventeen maxillary and 6 mandibular arches with four implants were randomly divided into a group with additional reference objects (wRO group, n = 12) and without them (woRO group, n = 11) and scanned with an intraoral scanner (IOS). For each jaw, the control model (CM) data was obtained to evaluate the deviations in the scan body positions in the wRO and woRO groups. CM and IOS data sets were imported into metrology software for distance and angle measurements between scan body pairs 1–2, 1–3, and 1–4. Unsigned values of distance and angle data differences between CM and IOS groups were used for further analysis.

Results

The highest statistically significant (p < 0.05) differences between distance and angulation measurements of the maxilla and mandible were observed in the 1–4 scan body pair group (136 ± 95 μm, 0.95° ± 0.79°; 362 ± 233 μm, 2.22° ± 2.11°, respectively). Distance deviations of the mandible were higher in all scan body pair groups. The woRO group had higher distance and angulation unsigned trueness values than in the wRO group, especially in the 1–4 scan body pair (224 ± 183 μm, 1.77° ± 1.76°;169 ± 162 μm, and 0.83° ± 0.57°, respectively).

Conclusions

IOS for the full-arch cases had statistically and clinically significant distance and angle deviations. Higher deviations were observed in the single mandibular scan body pair. The tendency of diminished distance and angular deviations with the utilization of the additional reference objects was observed, though these differences were not statistically significant.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Oral Implants Research
Clinical Oral Implants Research 医学-工程:生物医学
CiteScore
7.70
自引率
11.60%
发文量
149
审稿时长
3 months
期刊介绍: Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信