多轴锁定帽状钢板固定术用于固定移位的骨骺骨折的早期临床效果。

IF 1.2 Q3 ORTHOPEDICS
Michael Jason Gutman, Manan Sunil Patel, James William Connelly, Edward Scott Paxton, Surena Namdari, John Gabriel Horneff
{"title":"多轴锁定帽状钢板固定术用于固定移位的骨骺骨折的早期临床效果。","authors":"Michael Jason Gutman, Manan Sunil Patel, James William Connelly, Edward Scott Paxton, Surena Namdari, John Gabriel Horneff","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The purpose of this study is to evaluate the outcomes of a polyaxial locking plate utilizing locking-cap fixation for treatment of patients with displaced olecranon fractures.</p><p><strong>Methods: </strong>A retrospective review was performed for all consecutive patients at two institutions with displaced olecranon fractures treated with a polyaxial locking plate. Patients were required to have at least 1-year follow up. Clinical outcomes including the Disabilities of the Arm, Shoulder, and Hand (DASH) score, Single Assessment Numeric Evaluation (SANE), along with a Likert-scaled satisfaction survey ranging between 1-5 (1= very unsatisfied and 5= very satisfied) were collected.</p><p><strong>Results: </strong>The plate osteosynthesis was performed on 24 patients with displaced olecranon fractures. Functional outcome scores were collected on 19 (79.2%) patients. The mean age at the time of surgery was 57.9 years (range, 23 to 78) and mean clinical follow-up was 21.0 ± 6.6 months (range, 12-34 months). All patients achieved osseous union in an acceptable position. Four (16.7%) patients complained of plate related pain and 6 (25%) patients complained of postoperative stiffness. Complications were found in 3 (12.5 %) patients, which included two neuropathies and one hardware failure in which a patient presented following a fall with a broken screw. No patients required revision surgery nor removal of hardware. A total of 16 (84%) patients were somewhat to very satisfied. The mean SANE score was 87.8 ± 14.6 (range: 45-100) and the mean DASH score was 13.8 + 17.5 (range: 0-55.8). Seventeen (89%) patients rated their elbows as 75% or better on SANE assessment and 16 (84%) patients achieved DASH scores of less than 30.</p><p><strong>Conclusion: </strong>Polyaxial plate fixation utilizing locking-cap technology resulted in excellent short-term functional outcomes in patients with displaced olecranon fractures. Further follow-up is needed to determine the long-term outcomes of locking-cap constructs for olecranon fractures.</p>","PeriodicalId":46704,"journal":{"name":"Archives of Bone and Joint Surgery-ABJS","volume":"13 1","pages":"23-29"},"PeriodicalIF":1.2000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11776381/pdf/","citationCount":"0","resultStr":"{\"title\":\"Early Clinical Outcomes of Polyaxial Locking Cap Plate Fixation for Fixation of Displaced Olecranon Fractures.\",\"authors\":\"Michael Jason Gutman, Manan Sunil Patel, James William Connelly, Edward Scott Paxton, Surena Namdari, John Gabriel Horneff\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The purpose of this study is to evaluate the outcomes of a polyaxial locking plate utilizing locking-cap fixation for treatment of patients with displaced olecranon fractures.</p><p><strong>Methods: </strong>A retrospective review was performed for all consecutive patients at two institutions with displaced olecranon fractures treated with a polyaxial locking plate. Patients were required to have at least 1-year follow up. Clinical outcomes including the Disabilities of the Arm, Shoulder, and Hand (DASH) score, Single Assessment Numeric Evaluation (SANE), along with a Likert-scaled satisfaction survey ranging between 1-5 (1= very unsatisfied and 5= very satisfied) were collected.</p><p><strong>Results: </strong>The plate osteosynthesis was performed on 24 patients with displaced olecranon fractures. Functional outcome scores were collected on 19 (79.2%) patients. The mean age at the time of surgery was 57.9 years (range, 23 to 78) and mean clinical follow-up was 21.0 ± 6.6 months (range, 12-34 months). All patients achieved osseous union in an acceptable position. Four (16.7%) patients complained of plate related pain and 6 (25%) patients complained of postoperative stiffness. Complications were found in 3 (12.5 %) patients, which included two neuropathies and one hardware failure in which a patient presented following a fall with a broken screw. No patients required revision surgery nor removal of hardware. A total of 16 (84%) patients were somewhat to very satisfied. The mean SANE score was 87.8 ± 14.6 (range: 45-100) and the mean DASH score was 13.8 + 17.5 (range: 0-55.8). Seventeen (89%) patients rated their elbows as 75% or better on SANE assessment and 16 (84%) patients achieved DASH scores of less than 30.</p><p><strong>Conclusion: </strong>Polyaxial plate fixation utilizing locking-cap technology resulted in excellent short-term functional outcomes in patients with displaced olecranon fractures. Further follow-up is needed to determine the long-term outcomes of locking-cap constructs for olecranon fractures.</p>\",\"PeriodicalId\":46704,\"journal\":{\"name\":\"Archives of Bone and Joint Surgery-ABJS\",\"volume\":\"13 1\",\"pages\":\"23-29\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11776381/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Bone and Joint Surgery-ABJS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Bone and Joint Surgery-ABJS","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Early Clinical Outcomes of Polyaxial Locking Cap Plate Fixation for Fixation of Displaced Olecranon Fractures.

Objectives: The purpose of this study is to evaluate the outcomes of a polyaxial locking plate utilizing locking-cap fixation for treatment of patients with displaced olecranon fractures.

Methods: A retrospective review was performed for all consecutive patients at two institutions with displaced olecranon fractures treated with a polyaxial locking plate. Patients were required to have at least 1-year follow up. Clinical outcomes including the Disabilities of the Arm, Shoulder, and Hand (DASH) score, Single Assessment Numeric Evaluation (SANE), along with a Likert-scaled satisfaction survey ranging between 1-5 (1= very unsatisfied and 5= very satisfied) were collected.

Results: The plate osteosynthesis was performed on 24 patients with displaced olecranon fractures. Functional outcome scores were collected on 19 (79.2%) patients. The mean age at the time of surgery was 57.9 years (range, 23 to 78) and mean clinical follow-up was 21.0 ± 6.6 months (range, 12-34 months). All patients achieved osseous union in an acceptable position. Four (16.7%) patients complained of plate related pain and 6 (25%) patients complained of postoperative stiffness. Complications were found in 3 (12.5 %) patients, which included two neuropathies and one hardware failure in which a patient presented following a fall with a broken screw. No patients required revision surgery nor removal of hardware. A total of 16 (84%) patients were somewhat to very satisfied. The mean SANE score was 87.8 ± 14.6 (range: 45-100) and the mean DASH score was 13.8 + 17.5 (range: 0-55.8). Seventeen (89%) patients rated their elbows as 75% or better on SANE assessment and 16 (84%) patients achieved DASH scores of less than 30.

Conclusion: Polyaxial plate fixation utilizing locking-cap technology resulted in excellent short-term functional outcomes in patients with displaced olecranon fractures. Further follow-up is needed to determine the long-term outcomes of locking-cap constructs for olecranon fractures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
128
期刊介绍: The Archives of Bone and Joint Surgery (ABJS) aims to encourage a better understanding of all aspects of Orthopedic Sciences. The journal accepts scientific papers including original research, review article, short communication, case report, and letter to the editor in all fields of bone, joint, musculoskeletal surgery and related researches. The Archives of Bone and Joint Surgery (ABJS) will publish papers in all aspects of today`s modern orthopedic sciences including: Arthroscopy, Arthroplasty, Sport Medicine, Reconstruction, Hand and Upper Extremity, Pediatric Orthopedics, Spine, Trauma, Foot and Ankle, Tumor, Joint Rheumatic Disease, Skeletal Imaging, Orthopedic Physical Therapy, Rehabilitation, Orthopedic Basic Sciences (Biomechanics, Biotechnology, Biomaterial..).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信