口腔内扫描仪对龈下缘全冠预备牙的准确性:系统评价。

IF 1.2 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
M Andrade Villalobos, V Bennani, J M Aarts, J Ratnayake
{"title":"口腔内扫描仪对龈下缘全冠预备牙的准确性:系统评价。","authors":"M Andrade Villalobos, V Bennani, J M Aarts, J Ratnayake","doi":"10.1922/EJPRD_2812Matias09","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The accuracy of intra-oral scanners (IOS) has not been thoroughly evaluated across all clinical scenarios, particularly in crown preparations with subgingival margins.</p><p><strong>Objectives: </strong>This systematic review aims to assess the accuracy of IOS in tooth preparations with subgingival margins and identify factors influencing their performance in these situations.</p><p><strong>Methods: </strong>A comprehensive literature search was conducted in databases including PubMed, Scopus, Embase, Medline, Google Scholar, and Web of Science for studies published in the last five years. Quality Assessment Tool for In-Vitro Studies (QUIN) was used to evaluate study quality.</p><p><strong>Results: </strong>Out of 605 studies, seven met the inclusion and exclusion criteria. The review found that the trueness of IOS is significantly compromised in subgingival margins, often failing to achieve clinically acceptable results. Influencing factors included gingival retraction and saliva contamination. Specifically, cord retraction enhanced IOS accuracy, while saliva contamination reduced it.</p><p><strong>Conclusions: </strong>The accuracy of IOS in crown preparations with subgingival margins is severely affected by saliva contamination and visibility issues. Clinically acceptable results are achieved with proper gingival retraction and a dry field.</p><p><strong>Clinical relevance: </strong>To ensure accurate scanning for tooth preparations with subgingival margins, achieving proper gingival retraction and dryness is crucial.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"104-112"},"PeriodicalIF":1.2000,"publicationDate":"2025-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review.\",\"authors\":\"M Andrade Villalobos, V Bennani, J M Aarts, J Ratnayake\",\"doi\":\"10.1922/EJPRD_2812Matias09\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The accuracy of intra-oral scanners (IOS) has not been thoroughly evaluated across all clinical scenarios, particularly in crown preparations with subgingival margins.</p><p><strong>Objectives: </strong>This systematic review aims to assess the accuracy of IOS in tooth preparations with subgingival margins and identify factors influencing their performance in these situations.</p><p><strong>Methods: </strong>A comprehensive literature search was conducted in databases including PubMed, Scopus, Embase, Medline, Google Scholar, and Web of Science for studies published in the last five years. Quality Assessment Tool for In-Vitro Studies (QUIN) was used to evaluate study quality.</p><p><strong>Results: </strong>Out of 605 studies, seven met the inclusion and exclusion criteria. The review found that the trueness of IOS is significantly compromised in subgingival margins, often failing to achieve clinically acceptable results. Influencing factors included gingival retraction and saliva contamination. Specifically, cord retraction enhanced IOS accuracy, while saliva contamination reduced it.</p><p><strong>Conclusions: </strong>The accuracy of IOS in crown preparations with subgingival margins is severely affected by saliva contamination and visibility issues. Clinically acceptable results are achieved with proper gingival retraction and a dry field.</p><p><strong>Clinical relevance: </strong>To ensure accurate scanning for tooth preparations with subgingival margins, achieving proper gingival retraction and dryness is crucial.</p>\",\"PeriodicalId\":45686,\"journal\":{\"name\":\"European Journal of Prosthodontics and Restorative Dentistry\",\"volume\":\" \",\"pages\":\"104-112\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Prosthodontics and Restorative Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1922/EJPRD_2812Matias09\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2812Matias09","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

口腔内扫描仪(IOS)的准确性尚未在所有临床情况下进行彻底评估,特别是在龈下边缘的冠准备中。目的:本系统综述的目的是评估在龈下边缘的牙齿准备中使用IOS的准确性,并确定在这种情况下影响其性能的因素。方法:在PubMed、Scopus、Embase、Medline、谷歌Scholar、Web of Science等数据库中检索近5年发表的相关文献。采用体外研究质量评估工具(QUIN)评价研究质量。结果:605项研究中,有7项符合纳入和排除标准。回顾发现,在龈下边缘,IOS的准确性显著降低,常常无法达到临床可接受的结果。影响因素包括牙龈回缩和唾液污染。具体来说,脐带收缩提高了IOS的准确性,而唾液污染降低了它。结论:在龈下缘冠预备中,由于唾液污染和能见度问题,IOS的准确性受到严重影响。临床可接受的结果是取得适当的牙龈后缩和干野。临床意义:为了确保准确扫描牙龈下边缘的牙齿准备,实现适当的牙龈收缩和干燥是至关重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of Intra-Oral Scanners for Full Crown Tooth Preparations with Subgingival Margins: A Systematic Review.

Introduction: The accuracy of intra-oral scanners (IOS) has not been thoroughly evaluated across all clinical scenarios, particularly in crown preparations with subgingival margins.

Objectives: This systematic review aims to assess the accuracy of IOS in tooth preparations with subgingival margins and identify factors influencing their performance in these situations.

Methods: A comprehensive literature search was conducted in databases including PubMed, Scopus, Embase, Medline, Google Scholar, and Web of Science for studies published in the last five years. Quality Assessment Tool for In-Vitro Studies (QUIN) was used to evaluate study quality.

Results: Out of 605 studies, seven met the inclusion and exclusion criteria. The review found that the trueness of IOS is significantly compromised in subgingival margins, often failing to achieve clinically acceptable results. Influencing factors included gingival retraction and saliva contamination. Specifically, cord retraction enhanced IOS accuracy, while saliva contamination reduced it.

Conclusions: The accuracy of IOS in crown preparations with subgingival margins is severely affected by saliva contamination and visibility issues. Clinically acceptable results are achieved with proper gingival retraction and a dry field.

Clinical relevance: To ensure accurate scanning for tooth preparations with subgingival margins, achieving proper gingival retraction and dryness is crucial.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信