开发便携式检测室,以评估中低收入国家腹腔镜成像性能。

IF 3 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Journal of Biomedical Optics Pub Date : 2025-01-01 Epub Date: 2025-01-30 DOI:10.1117/1.JBO.30.1.016001
Anne Christine Barnes, Michele Kaluzienski, Tri Quang, Jason Chen, Surabhi Singh, Wilhelm Smith, Talya Simcox, Paula Kworekwa, Rebecca Kaaya Nansubuga, Robert Ssekitoleko, Tamara N Fitzgerald, Jenna L Mueller
{"title":"开发便携式检测室,以评估中低收入国家腹腔镜成像性能。","authors":"Anne Christine Barnes, Michele Kaluzienski, Tri Quang, Jason Chen, Surabhi Singh, Wilhelm Smith, Talya Simcox, Paula Kworekwa, Rebecca Kaaya Nansubuga, Robert Ssekitoleko, Tamara N Fitzgerald, Jenna L Mueller","doi":"10.1117/1.JBO.30.1.016001","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Laparoscopic surgery is generally unavailable in low- and middle-income countries (LMICs) due to the high cost of installation and lack of qualified personnel to maintain and repair equipment. We developed a low-cost, durable, reusable laparoscopic system, called the KeyScope laparoscope, for use in LMICs. To reliably build and service the KeyScope in LMICs, a portable testing chamber (PTC) is needed to assess image performance.</p><p><strong>Aim: </strong>A PTC was developed to characterize KeyScope laparoscope performance in LMICs.</p><p><strong>Approach: </strong>Images of standard resolution, color accuracy, distortion, and depth of field (DOF) targets were captured in both a standard optical bench setup (OBS) and the PTC. Measurements from the OBS and PTC were quantified and compared using standard software (ImageJ and Imatest). To further reduce cost, alternative paper imaging targets were identified and compared with standard glass targets. To improve usability, MATLAB applications (apps) were developed to automate image analysis and reduce cost.</p><p><strong>Results: </strong>The PTC achieved similar results compared to the OBS for the image quality metrics, distortion and DOF. Further, the PTC presented similar results to the OBS for resolution at 4 to 7 cm working distances and improved resolution at periphery working distances of 3 and 10 cm. Color accuracy values were also improved in the PTC compared with those measured in the OBS. The low-cost resolution, color accuracy, and distortion targets resulted in similar image quality results to the standard image quality target. MATLAB apps produced similar results to Imatest and ImageJ software and decreased the time to complete image quality test analysis.</p><p><strong>Conclusion: </strong>The low-cost portable design of the PTC will facilitate the translation of the KeyScope by enabling accurate and fast characterization of laparoscopic imaging performance in LMICs.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"30 1","pages":"016001"},"PeriodicalIF":3.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11781219/pdf/","citationCount":"0","resultStr":"{\"title\":\"Development of a portable testing chamber to assess imaging performance of laparoscopes in low- and middle-income countries.\",\"authors\":\"Anne Christine Barnes, Michele Kaluzienski, Tri Quang, Jason Chen, Surabhi Singh, Wilhelm Smith, Talya Simcox, Paula Kworekwa, Rebecca Kaaya Nansubuga, Robert Ssekitoleko, Tamara N Fitzgerald, Jenna L Mueller\",\"doi\":\"10.1117/1.JBO.30.1.016001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Significance: </strong>Laparoscopic surgery is generally unavailable in low- and middle-income countries (LMICs) due to the high cost of installation and lack of qualified personnel to maintain and repair equipment. We developed a low-cost, durable, reusable laparoscopic system, called the KeyScope laparoscope, for use in LMICs. To reliably build and service the KeyScope in LMICs, a portable testing chamber (PTC) is needed to assess image performance.</p><p><strong>Aim: </strong>A PTC was developed to characterize KeyScope laparoscope performance in LMICs.</p><p><strong>Approach: </strong>Images of standard resolution, color accuracy, distortion, and depth of field (DOF) targets were captured in both a standard optical bench setup (OBS) and the PTC. Measurements from the OBS and PTC were quantified and compared using standard software (ImageJ and Imatest). To further reduce cost, alternative paper imaging targets were identified and compared with standard glass targets. To improve usability, MATLAB applications (apps) were developed to automate image analysis and reduce cost.</p><p><strong>Results: </strong>The PTC achieved similar results compared to the OBS for the image quality metrics, distortion and DOF. Further, the PTC presented similar results to the OBS for resolution at 4 to 7 cm working distances and improved resolution at periphery working distances of 3 and 10 cm. Color accuracy values were also improved in the PTC compared with those measured in the OBS. The low-cost resolution, color accuracy, and distortion targets resulted in similar image quality results to the standard image quality target. MATLAB apps produced similar results to Imatest and ImageJ software and decreased the time to complete image quality test analysis.</p><p><strong>Conclusion: </strong>The low-cost portable design of the PTC will facilitate the translation of the KeyScope by enabling accurate and fast characterization of laparoscopic imaging performance in LMICs.</p>\",\"PeriodicalId\":15264,\"journal\":{\"name\":\"Journal of Biomedical Optics\",\"volume\":\"30 1\",\"pages\":\"016001\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11781219/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomedical Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JBO.30.1.016001\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.30.1.016001","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

意义:在低收入和中等收入国家(LMICs),由于安装成本高和缺乏合格的人员来维护和修理设备,腹腔镜手术通常无法实现。我们开发了一种低成本,耐用,可重复使用的腹腔镜系统,称为KeyScope腹腔镜,用于低收入国家。为了在低收入国家中可靠地构建和维护KeyScope,需要一个便携式测试箱(PTC)来评估图像性能。目的:开发一种PTC来表征KeyScope腹腔镜在低mic中的表现。方法:在标准光学台架设置(OBS)和PTC中捕获标准分辨率,色彩精度,失真和景深(DOF)目标的图像。使用标准软件(ImageJ和Imatest)对OBS和PTC测量结果进行量化和比较。为了进一步降低成本,确定了替代纸质成像靶,并与标准玻璃靶进行了比较。为了提高可用性,开发了MATLAB应用程序(应用程序)来自动化图像分析并降低成本。结果:与OBS相比,PTC在图像质量指标,失真和DOF方面取得了相似的结果。此外,PTC在4至7 cm工作距离下的分辨率与OBS相似,在3和10 cm外围工作距离下的分辨率有所提高。与OBS相比,PTC的色彩精度值也有所提高。低成本的分辨率、色彩精度和失真目标导致了与标准图像质量目标相似的图像质量结果。MATLAB应用程序产生的结果与Imatest和ImageJ软件相似,并且减少了完成图像质量测试分析的时间。结论:PTC的低成本便携式设计将有助于KeyScope的翻译,从而能够准确、快速地表征低收入国家的腹腔镜成像性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a portable testing chamber to assess imaging performance of laparoscopes in low- and middle-income countries.

Significance: Laparoscopic surgery is generally unavailable in low- and middle-income countries (LMICs) due to the high cost of installation and lack of qualified personnel to maintain and repair equipment. We developed a low-cost, durable, reusable laparoscopic system, called the KeyScope laparoscope, for use in LMICs. To reliably build and service the KeyScope in LMICs, a portable testing chamber (PTC) is needed to assess image performance.

Aim: A PTC was developed to characterize KeyScope laparoscope performance in LMICs.

Approach: Images of standard resolution, color accuracy, distortion, and depth of field (DOF) targets were captured in both a standard optical bench setup (OBS) and the PTC. Measurements from the OBS and PTC were quantified and compared using standard software (ImageJ and Imatest). To further reduce cost, alternative paper imaging targets were identified and compared with standard glass targets. To improve usability, MATLAB applications (apps) were developed to automate image analysis and reduce cost.

Results: The PTC achieved similar results compared to the OBS for the image quality metrics, distortion and DOF. Further, the PTC presented similar results to the OBS for resolution at 4 to 7 cm working distances and improved resolution at periphery working distances of 3 and 10 cm. Color accuracy values were also improved in the PTC compared with those measured in the OBS. The low-cost resolution, color accuracy, and distortion targets resulted in similar image quality results to the standard image quality target. MATLAB apps produced similar results to Imatest and ImageJ software and decreased the time to complete image quality test analysis.

Conclusion: The low-cost portable design of the PTC will facilitate the translation of the KeyScope by enabling accurate and fast characterization of laparoscopic imaging performance in LMICs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信