扫描源光学相干层析成像计算近视的晶状体功率和散光:一项初步研究。

IF 2.4 3区 医学 Q2 OPHTHALMOLOGY
Shulin Wang, Dan Cheng, Xueying Zhu, Fangjun Bao, Jun Zhu, Chenjiu Pang, Yufeng Ye
{"title":"扫描源光学相干层析成像计算近视的晶状体功率和散光:一项初步研究。","authors":"Shulin Wang, Dan Cheng, Xueying Zhu, Fangjun Bao, Jun Zhu, Chenjiu Pang, Yufeng Ye","doi":"10.1007/s00417-025-06746-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To calculate the crystalline lens power and astigmatism, as well as their changes following cycloplegia, in individuals with myopia using swept-source optical coherence tomography (SS-OCT).</p><p><strong>Methods: </strong>Participants were divided into two groups according to axial length (AL). Crystalline lens parameters, including power, lens thickness (LT), anterior chamber depth (ACD), and astigmatism, were measured with SS-OCT and analysed before and after cycloplegia. The lensmaker's equation was used to calculate lens power, and differences between three consecutive measurements < 22.5 degrees was set as the screening criterion for meridian direction measurement repeatability.</p><p><strong>Results: </strong>Sixty-three eyes met the screening criterion on the anterior surface both before and after cycloplegia was included. The majority of eyes exhibited lens astigmatism ranging from + 0.76 D to + 1.50 D on both anterior and posterior surfaces. Before cycloplegia, 61 eyes (96.8%) had with-the-rule (WTR) astigmatism on the anterior surface. Meanwhile, 25 eyes met the criterion on posterior surface, of which 21 eyes (84.0%) had against-the-rule (ATR) astigmatism. After cycloplegia, 60 eyes (95.2%) had WTR astigmatism on the anterior surface. Meanwhile, 23 eyes met the criterion on posterior surface, of which 19 eyes (82.6%) had ATR astigmatism. After cycloplegia, there were significant changes in the lens power, astigmatism, thickness, and ACD.</p><p><strong>Conclusions: </strong>Astigmatism of crystalline lens on the anterior and posterior surfaces was mainly WTR and ATR, respectively, with similar refractive power. After cycloplegia, changes in parameters and refractive power of the lens mainly occur on the anterior surface.</p>","PeriodicalId":12795,"journal":{"name":"Graefe’s Archive for Clinical and Experimental Ophthalmology","volume":" ","pages":"1355-1363"},"PeriodicalIF":2.4000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Crystalline lens power and astigmatism calculation in myopia by swept-source optical coherence tomography: A pilot study.\",\"authors\":\"Shulin Wang, Dan Cheng, Xueying Zhu, Fangjun Bao, Jun Zhu, Chenjiu Pang, Yufeng Ye\",\"doi\":\"10.1007/s00417-025-06746-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To calculate the crystalline lens power and astigmatism, as well as their changes following cycloplegia, in individuals with myopia using swept-source optical coherence tomography (SS-OCT).</p><p><strong>Methods: </strong>Participants were divided into two groups according to axial length (AL). Crystalline lens parameters, including power, lens thickness (LT), anterior chamber depth (ACD), and astigmatism, were measured with SS-OCT and analysed before and after cycloplegia. The lensmaker's equation was used to calculate lens power, and differences between three consecutive measurements < 22.5 degrees was set as the screening criterion for meridian direction measurement repeatability.</p><p><strong>Results: </strong>Sixty-three eyes met the screening criterion on the anterior surface both before and after cycloplegia was included. The majority of eyes exhibited lens astigmatism ranging from + 0.76 D to + 1.50 D on both anterior and posterior surfaces. Before cycloplegia, 61 eyes (96.8%) had with-the-rule (WTR) astigmatism on the anterior surface. Meanwhile, 25 eyes met the criterion on posterior surface, of which 21 eyes (84.0%) had against-the-rule (ATR) astigmatism. After cycloplegia, 60 eyes (95.2%) had WTR astigmatism on the anterior surface. Meanwhile, 23 eyes met the criterion on posterior surface, of which 19 eyes (82.6%) had ATR astigmatism. After cycloplegia, there were significant changes in the lens power, astigmatism, thickness, and ACD.</p><p><strong>Conclusions: </strong>Astigmatism of crystalline lens on the anterior and posterior surfaces was mainly WTR and ATR, respectively, with similar refractive power. After cycloplegia, changes in parameters and refractive power of the lens mainly occur on the anterior surface.</p>\",\"PeriodicalId\":12795,\"journal\":{\"name\":\"Graefe’s Archive for Clinical and Experimental Ophthalmology\",\"volume\":\" \",\"pages\":\"1355-1363\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Graefe’s Archive for Clinical and Experimental Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00417-025-06746-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe’s Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-025-06746-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:利用扫源光学相干断层扫描(SS-OCT)计算近视患者的晶状体度数和散光及其在睫状体麻痹后的变化。方法:受试者按轴向长度(AL)分为两组。采用SS-OCT测量患者晶状体的度数、晶状体厚度(LT)、前房深度(ACD)、散光等晶状体参数,并对截瘫前后进行分析。采用lensmaker’s方程计算晶状体度数,计算连续三次测量结果的差异。结果:包括63只眼在睫状体麻痹前后的前表面符合筛选标准。大多数眼睛的晶状体前、后表面散光在+ 0.76 ~ + 1.50 D之间。单眼截瘫前,61眼(96.8%)前表面有顺条性散光。后表面符合标准25眼,其中反规则散光21眼(84.0%)。单眼截瘫后,前表面WTR散光60眼(95.2%)。后表面符合标准的有23眼,其中ATR散光19眼(82.6%)。睫状体截瘫后晶状体度数、散光、厚度、ACD均有显著变化。结论:晶状体前、后表面散光分别以WTR和ATR为主,屈光度相近。睫状体截瘫后,晶状体参数和屈光度的变化主要发生在晶状体前表面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Crystalline lens power and astigmatism calculation in myopia by swept-source optical coherence tomography: A pilot study.

Purpose: To calculate the crystalline lens power and astigmatism, as well as their changes following cycloplegia, in individuals with myopia using swept-source optical coherence tomography (SS-OCT).

Methods: Participants were divided into two groups according to axial length (AL). Crystalline lens parameters, including power, lens thickness (LT), anterior chamber depth (ACD), and astigmatism, were measured with SS-OCT and analysed before and after cycloplegia. The lensmaker's equation was used to calculate lens power, and differences between three consecutive measurements < 22.5 degrees was set as the screening criterion for meridian direction measurement repeatability.

Results: Sixty-three eyes met the screening criterion on the anterior surface both before and after cycloplegia was included. The majority of eyes exhibited lens astigmatism ranging from + 0.76 D to + 1.50 D on both anterior and posterior surfaces. Before cycloplegia, 61 eyes (96.8%) had with-the-rule (WTR) astigmatism on the anterior surface. Meanwhile, 25 eyes met the criterion on posterior surface, of which 21 eyes (84.0%) had against-the-rule (ATR) astigmatism. After cycloplegia, 60 eyes (95.2%) had WTR astigmatism on the anterior surface. Meanwhile, 23 eyes met the criterion on posterior surface, of which 19 eyes (82.6%) had ATR astigmatism. After cycloplegia, there were significant changes in the lens power, astigmatism, thickness, and ACD.

Conclusions: Astigmatism of crystalline lens on the anterior and posterior surfaces was mainly WTR and ATR, respectively, with similar refractive power. After cycloplegia, changes in parameters and refractive power of the lens mainly occur on the anterior surface.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.40
自引率
7.40%
发文量
398
审稿时长
3 months
期刊介绍: Graefe''s Archive for Clinical and Experimental Ophthalmology is a distinguished international journal that presents original clinical reports and clini-cally relevant experimental studies. Founded in 1854 by Albrecht von Graefe to serve as a source of useful clinical information and a stimulus for discussion, the journal has published articles by leading ophthalmologists and vision research scientists for more than a century. With peer review by an international Editorial Board and prompt English-language publication, Graefe''s Archive provides rapid dissemination of clinical and clinically related experimental information.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信