新型部分结晶二硅酸锂CAD-CAM材料的性能研究。

IF 2.2 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
J M Wells, J W Johnson, W Lien, C Raimondi, M Caballero, T F Gibbons, K S Vandewalle
{"title":"新型部分结晶二硅酸锂CAD-CAM材料的性能研究。","authors":"J M Wells, J W Johnson, W Lien, C Raimondi, M Caballero, T F Gibbons, K S Vandewalle","doi":"10.2341/23-165-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The purpose of this study was to compare the optical, mechanical, and biological properties of two new, inexpensive lithium disilicate (LS2) materials (Lodden (LOD), LD Medical Technology; and BeautyZir (BZ), BeautyZir Technology) to a clinically established LS2 material (IPS e.max CAD (EMAX), Ivoclar Vivadent).</p><p><strong>Methods and materials: </strong>The optical properties of the translucency parameter (TP) and opalescence parameter (OP) were obtained with a dental spectrophotometer. The mechanical properties of flexural strength (FS) and flexural modulus (FM) were determined through a three-point bend test conducted using a universal testing machine. Biocompatibility tests were conducted by analyzing cell proliferation using spectrophotometric absorbance (optical density) to determine relative growth rate and cytotoxicity. Representative specimens of the three LS2 materials were analyzed with X-ray diffraction to determine the relative crystalline phases. Data were analyzed with oneway ANOVA and Tukey's post hoc test (α=0.05).</p><p><strong>Results: </strong>Significant differences in optical and mechanical properties were found amongst the groups (p<0.05). Both LOD and BZ had significantly greater TP and OP compared to EMAX. EMAX and LOD had greater FS and FM than BZ. No significant differences in optical density or relative growth rate were found among any of the LS2 groups (p>0.05). EMAX and LOD had greater weight percent of lithium disilicate than BZ.</p><p><strong>Conclusions: </strong>The new lithium disilicate LS2 material, LOD, exhibited better optical properties while maintaining mechanical and biological properties similar to the established LS2 material, EMAX.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"50 1","pages":"93-100"},"PeriodicalIF":2.2000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Properties of New Partially Crystallized Lithium Disilicate CAD-CAM Materials.\",\"authors\":\"J M Wells, J W Johnson, W Lien, C Raimondi, M Caballero, T F Gibbons, K S Vandewalle\",\"doi\":\"10.2341/23-165-L\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The purpose of this study was to compare the optical, mechanical, and biological properties of two new, inexpensive lithium disilicate (LS2) materials (Lodden (LOD), LD Medical Technology; and BeautyZir (BZ), BeautyZir Technology) to a clinically established LS2 material (IPS e.max CAD (EMAX), Ivoclar Vivadent).</p><p><strong>Methods and materials: </strong>The optical properties of the translucency parameter (TP) and opalescence parameter (OP) were obtained with a dental spectrophotometer. The mechanical properties of flexural strength (FS) and flexural modulus (FM) were determined through a three-point bend test conducted using a universal testing machine. Biocompatibility tests were conducted by analyzing cell proliferation using spectrophotometric absorbance (optical density) to determine relative growth rate and cytotoxicity. Representative specimens of the three LS2 materials were analyzed with X-ray diffraction to determine the relative crystalline phases. Data were analyzed with oneway ANOVA and Tukey's post hoc test (α=0.05).</p><p><strong>Results: </strong>Significant differences in optical and mechanical properties were found amongst the groups (p<0.05). Both LOD and BZ had significantly greater TP and OP compared to EMAX. EMAX and LOD had greater FS and FM than BZ. No significant differences in optical density or relative growth rate were found among any of the LS2 groups (p>0.05). EMAX and LOD had greater weight percent of lithium disilicate than BZ.</p><p><strong>Conclusions: </strong>The new lithium disilicate LS2 material, LOD, exhibited better optical properties while maintaining mechanical and biological properties similar to the established LS2 material, EMAX.</p>\",\"PeriodicalId\":19502,\"journal\":{\"name\":\"Operative dentistry\",\"volume\":\"50 1\",\"pages\":\"93-100\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Operative dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2341/23-165-L\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/23-165-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较两种新型廉价的二硅酸锂(LS2)材料(Lodden (LOD), LD Medical Technology;和BeautyZir (BZ), BeautyZir Technology)结合到临床建立的LS2材料(IPS e.max CAD (EMAX), Ivoclar Vivadent)。方法与材料:采用牙用分光光度计测定半透明参数(TP)和乳光参数(OP)的光学性质。通过在万能试验机上进行三点弯曲试验,确定了弯曲强度(FS)和弯曲模量(FM)的力学性能。生物相容性试验采用分光光度法(光密度)分析细胞增殖,以确定相对生长速率和细胞毒性。对三种LS2材料的代表性样品进行x射线衍射分析,确定其相对晶相。数据分析采用单因素方差分析和Tukey事后检验(α=0.05)。结果:各组间光学、力学性能差异有统计学意义(p0.05)。EMAX和LOD的二硅酸锂含量比BZ高。结论:新型二硅酸锂LS2材料LOD具有更好的光学性能,同时保持了与现有LS2材料EMAX相似的机械和生物性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Properties of New Partially Crystallized Lithium Disilicate CAD-CAM Materials.

Objective: The purpose of this study was to compare the optical, mechanical, and biological properties of two new, inexpensive lithium disilicate (LS2) materials (Lodden (LOD), LD Medical Technology; and BeautyZir (BZ), BeautyZir Technology) to a clinically established LS2 material (IPS e.max CAD (EMAX), Ivoclar Vivadent).

Methods and materials: The optical properties of the translucency parameter (TP) and opalescence parameter (OP) were obtained with a dental spectrophotometer. The mechanical properties of flexural strength (FS) and flexural modulus (FM) were determined through a three-point bend test conducted using a universal testing machine. Biocompatibility tests were conducted by analyzing cell proliferation using spectrophotometric absorbance (optical density) to determine relative growth rate and cytotoxicity. Representative specimens of the three LS2 materials were analyzed with X-ray diffraction to determine the relative crystalline phases. Data were analyzed with oneway ANOVA and Tukey's post hoc test (α=0.05).

Results: Significant differences in optical and mechanical properties were found amongst the groups (p<0.05). Both LOD and BZ had significantly greater TP and OP compared to EMAX. EMAX and LOD had greater FS and FM than BZ. No significant differences in optical density or relative growth rate were found among any of the LS2 groups (p>0.05). EMAX and LOD had greater weight percent of lithium disilicate than BZ.

Conclusions: The new lithium disilicate LS2 material, LOD, exhibited better optical properties while maintaining mechanical and biological properties similar to the established LS2 material, EMAX.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信