{"title":"金属屏蔽层对玻璃-硅阳极键合中静电吸引问题的影响","authors":"Wenqi Yang, Yong Ruan, Zhiqiang Song","doi":"10.3390/mi16010031","DOIUrl":null,"url":null,"abstract":"<p><p>Silicon-glass anode bonding is the key technology in the process of wafer-level packaging for MEMS sensors. During the anodic bonding process, the device may experience adhesion failure due to the influence of electric field forces. A common solution is to add a metal shielding layer between the glass substrate and the device. In order to solve the problem of device failure caused by the electrostatic attraction phenomenon, this paper designed a double-ended solidly supported cantilever beam parallel plate capacitor structure, focusing on the study of the critical size of the window opening in the metal layer for the electric field shielding effect. The metal shield consists of 400 Å of Cr and 3400 Å of Au. Based on theoretical calculations, simulation analysis, and experimental testing, it was determined that the critical size for an individual opening in the metal layer is 180 μm × 180 μm, with the movable part positioned 5 μm from the bottom, which does not lead to failure caused by stiction due to electrostatic pull-in of the detection structure. It was proven that the metal shielding layer is effective in avoiding suction problems in secondary anode bonding.</p>","PeriodicalId":18508,"journal":{"name":"Micromachines","volume":"16 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11767765/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Effect of Metal Shielding Layer on Electrostatic Attraction Issue in Glass-Silicon Anodic Bonding.\",\"authors\":\"Wenqi Yang, Yong Ruan, Zhiqiang Song\",\"doi\":\"10.3390/mi16010031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Silicon-glass anode bonding is the key technology in the process of wafer-level packaging for MEMS sensors. During the anodic bonding process, the device may experience adhesion failure due to the influence of electric field forces. A common solution is to add a metal shielding layer between the glass substrate and the device. In order to solve the problem of device failure caused by the electrostatic attraction phenomenon, this paper designed a double-ended solidly supported cantilever beam parallel plate capacitor structure, focusing on the study of the critical size of the window opening in the metal layer for the electric field shielding effect. The metal shield consists of 400 Å of Cr and 3400 Å of Au. Based on theoretical calculations, simulation analysis, and experimental testing, it was determined that the critical size for an individual opening in the metal layer is 180 μm × 180 μm, with the movable part positioned 5 μm from the bottom, which does not lead to failure caused by stiction due to electrostatic pull-in of the detection structure. It was proven that the metal shielding layer is effective in avoiding suction problems in secondary anode bonding.</p>\",\"PeriodicalId\":18508,\"journal\":{\"name\":\"Micromachines\",\"volume\":\"16 1\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-12-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11767765/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Micromachines\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/mi16010031\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micromachines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/mi16010031","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
The Effect of Metal Shielding Layer on Electrostatic Attraction Issue in Glass-Silicon Anodic Bonding.
Silicon-glass anode bonding is the key technology in the process of wafer-level packaging for MEMS sensors. During the anodic bonding process, the device may experience adhesion failure due to the influence of electric field forces. A common solution is to add a metal shielding layer between the glass substrate and the device. In order to solve the problem of device failure caused by the electrostatic attraction phenomenon, this paper designed a double-ended solidly supported cantilever beam parallel plate capacitor structure, focusing on the study of the critical size of the window opening in the metal layer for the electric field shielding effect. The metal shield consists of 400 Å of Cr and 3400 Å of Au. Based on theoretical calculations, simulation analysis, and experimental testing, it was determined that the critical size for an individual opening in the metal layer is 180 μm × 180 μm, with the movable part positioned 5 μm from the bottom, which does not lead to failure caused by stiction due to electrostatic pull-in of the detection structure. It was proven that the metal shielding layer is effective in avoiding suction problems in secondary anode bonding.
期刊介绍:
Micromachines (ISSN 2072-666X) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to micro-scaled machines and micromachinery. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.