荧光偏振免疫法快速、灵敏地检测果汁和水样中除草剂2,4-二氯苯氧乙酸。

IF 4.9 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL
Liliya I Mukhametova, Marya K Kolokolova, Ivan A Shevchenko, Boris S Tupertsev, Anatoly V Zherdev, Chuanlai Xu, Sergei A Eremin
{"title":"荧光偏振免疫法快速、灵敏地检测果汁和水样中除草剂2,4-二氯苯氧乙酸。","authors":"Liliya I Mukhametova, Marya K Kolokolova, Ivan A Shevchenko, Boris S Tupertsev, Anatoly V Zherdev, Chuanlai Xu, Sergei A Eremin","doi":"10.3390/bios15010032","DOIUrl":null,"url":null,"abstract":"<p><p>2,4-Dichlorophenoxyacetic acid (2,4-D) is one of the popular herbicides that is widely used in agriculture and can be found in food and water. A rapid and sensitive fluorescence polarization immunoassay (FPIA) was proposed for the detection of 2,4-D in juice and water. New tracers, 2,4-D-buthylenediamin fluoresceinthiocarbamyl (2,4-D-BDF) and 2,4-D-glycine aminofluorescein (2,4-D-GAF), were obtained and characterized. Monoclonal antibodies (MAb) obtained against 2,4-D were used as a recognition reagent. The kinetics of the interaction of MAb and tracers were studied, and the kinetic parameters of their binding were calculated. High specificity of binding of tracers and MAb was shown. In this work, an approach was elaborated on to reduce the detection limit of 2,4-D by the FPIA method by changing the volume of the studied sample. The optimized FPIA in a competitive format was characterized by the LODs of 2,4-D 8 and 0.4 ng/mL and the working ranges 30-3000 ng/mL and 3-300 ng/mL for juice and water, respectively. The entire test cycle (from sample receipt to evaluation of the analysis results) took only 20 min. The test for the recovery of 2,4-D in juice and water gave values from 95 to 120%, which demonstrated the reliability of the herbicide determination in real samples.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"15 1","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11763590/pdf/","citationCount":"0","resultStr":"{\"title\":\"Fluorescence Polarization Immunoassay for Rapid, Sensitive Detection of the Herbicide 2,4-Dichlorophenoxyacetic Acid in Juice and Water Samples.\",\"authors\":\"Liliya I Mukhametova, Marya K Kolokolova, Ivan A Shevchenko, Boris S Tupertsev, Anatoly V Zherdev, Chuanlai Xu, Sergei A Eremin\",\"doi\":\"10.3390/bios15010032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>2,4-Dichlorophenoxyacetic acid (2,4-D) is one of the popular herbicides that is widely used in agriculture and can be found in food and water. A rapid and sensitive fluorescence polarization immunoassay (FPIA) was proposed for the detection of 2,4-D in juice and water. New tracers, 2,4-D-buthylenediamin fluoresceinthiocarbamyl (2,4-D-BDF) and 2,4-D-glycine aminofluorescein (2,4-D-GAF), were obtained and characterized. Monoclonal antibodies (MAb) obtained against 2,4-D were used as a recognition reagent. The kinetics of the interaction of MAb and tracers were studied, and the kinetic parameters of their binding were calculated. High specificity of binding of tracers and MAb was shown. In this work, an approach was elaborated on to reduce the detection limit of 2,4-D by the FPIA method by changing the volume of the studied sample. The optimized FPIA in a competitive format was characterized by the LODs of 2,4-D 8 and 0.4 ng/mL and the working ranges 30-3000 ng/mL and 3-300 ng/mL for juice and water, respectively. The entire test cycle (from sample receipt to evaluation of the analysis results) took only 20 min. The test for the recovery of 2,4-D in juice and water gave values from 95 to 120%, which demonstrated the reliability of the herbicide determination in real samples.</p>\",\"PeriodicalId\":48608,\"journal\":{\"name\":\"Biosensors-Basel\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2025-01-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11763590/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors-Basel\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bios15010032\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios15010032","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

2,4-二氯苯氧乙酸(2,4- d)是一种广泛应用于农业的常用除草剂,可在食品和水中找到。建立了一种快速、灵敏的荧光偏振免疫分析法(FPIA)检测果汁和水中2,4- d的方法。获得了新的示踪剂2,4- d -丁二胺荧光硫代氨基甲酰基(2,4- d - bdf)和2,4- d -甘氨酸氨基荧光素(2,4- d - gaf)并对其进行了表征。获得的2,4- d单克隆抗体(MAb)作为识别试剂。研究了单抗与示踪剂的相互作用动力学,并计算了它们结合的动力学参数。显示示踪剂与单抗结合的高特异性。本文阐述了一种通过改变研究样品的体积来降低FPIA法2,4- d检出限的方法。优化后的ffia在竞争格式下的lod分别为2,4- d8和0.4 ng/mL,果汁和水的工作范围分别为30 ~ 3000 ng/mL和3 ~ 300 ng/mL。整个测试周期(从样品接收到分析结果的评估)仅需20分钟。果汁和水中2,4- d的回收率测试值为95 ~ 120%,证明了除草剂测定在实际样品中的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fluorescence Polarization Immunoassay for Rapid, Sensitive Detection of the Herbicide 2,4-Dichlorophenoxyacetic Acid in Juice and Water Samples.

2,4-Dichlorophenoxyacetic acid (2,4-D) is one of the popular herbicides that is widely used in agriculture and can be found in food and water. A rapid and sensitive fluorescence polarization immunoassay (FPIA) was proposed for the detection of 2,4-D in juice and water. New tracers, 2,4-D-buthylenediamin fluoresceinthiocarbamyl (2,4-D-BDF) and 2,4-D-glycine aminofluorescein (2,4-D-GAF), were obtained and characterized. Monoclonal antibodies (MAb) obtained against 2,4-D were used as a recognition reagent. The kinetics of the interaction of MAb and tracers were studied, and the kinetic parameters of their binding were calculated. High specificity of binding of tracers and MAb was shown. In this work, an approach was elaborated on to reduce the detection limit of 2,4-D by the FPIA method by changing the volume of the studied sample. The optimized FPIA in a competitive format was characterized by the LODs of 2,4-D 8 and 0.4 ng/mL and the working ranges 30-3000 ng/mL and 3-300 ng/mL for juice and water, respectively. The entire test cycle (from sample receipt to evaluation of the analysis results) took only 20 min. The test for the recovery of 2,4-D in juice and water gave values from 95 to 120%, which demonstrated the reliability of the herbicide determination in real samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信