Osman Koc, Mostafa Mahmoud, Ehab Mahmoud, Ali Ayyad, Ahmad Own
{"title":"轮廓装置血管内治疗后迟发性动脉瘤破裂1例报告。","authors":"Osman Koc, Mostafa Mahmoud, Ehab Mahmoud, Ali Ayyad, Ahmad Own","doi":"10.5469/neuroint.2024.00493","DOIUrl":null,"url":null,"abstract":"<p><p>Delayed rupture of intracranial aneurysms after endovascular treatment is a rare but serious complication. We report the first documented case of late aneurysmal rupture following treatment with a Contour intrasaccular device. A patient in their 60s with a basilar tip aneurysm underwent endovascular treatment using a 14-mm Contour device. Fifteen months later, the patient presented with a fatal intraventricular hemorrhage, and imaging revealed device displacement and aneurysm growth. This case underscores the importance of meticulous device sizing and follow-up, especially for large aneurysms.</p>","PeriodicalId":19140,"journal":{"name":"Neurointervention","volume":" ","pages":"24-27"},"PeriodicalIF":1.2000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11900283/pdf/","citationCount":"0","resultStr":"{\"title\":\"Delayed Aneurysm Rupture Following Endovascular Treatment with Contour Device: A Case Report.\",\"authors\":\"Osman Koc, Mostafa Mahmoud, Ehab Mahmoud, Ali Ayyad, Ahmad Own\",\"doi\":\"10.5469/neuroint.2024.00493\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Delayed rupture of intracranial aneurysms after endovascular treatment is a rare but serious complication. We report the first documented case of late aneurysmal rupture following treatment with a Contour intrasaccular device. A patient in their 60s with a basilar tip aneurysm underwent endovascular treatment using a 14-mm Contour device. Fifteen months later, the patient presented with a fatal intraventricular hemorrhage, and imaging revealed device displacement and aneurysm growth. This case underscores the importance of meticulous device sizing and follow-up, especially for large aneurysms.</p>\",\"PeriodicalId\":19140,\"journal\":{\"name\":\"Neurointervention\",\"volume\":\" \",\"pages\":\"24-27\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11900283/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurointervention\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5469/neuroint.2024.00493\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurointervention","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5469/neuroint.2024.00493","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/24 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Delayed Aneurysm Rupture Following Endovascular Treatment with Contour Device: A Case Report.
Delayed rupture of intracranial aneurysms after endovascular treatment is a rare but serious complication. We report the first documented case of late aneurysmal rupture following treatment with a Contour intrasaccular device. A patient in their 60s with a basilar tip aneurysm underwent endovascular treatment using a 14-mm Contour device. Fifteen months later, the patient presented with a fatal intraventricular hemorrhage, and imaging revealed device displacement and aneurysm growth. This case underscores the importance of meticulous device sizing and follow-up, especially for large aneurysms.