Kusumiyati Kusumiyati, Ine Elisa Putri, Yuda Hadiwijaya, Agitha Kartika, Yusuf Eka Maulana, Wawan Sutari
{"title":"万寿菊食用花中总类胡萝卜素和槲皮素的质量保证。","authors":"Kusumiyati Kusumiyati, Ine Elisa Putri, Yuda Hadiwijaya, Agitha Kartika, Yusuf Eka Maulana, Wawan Sutari","doi":"10.1155/ijfo/3277288","DOIUrl":null,"url":null,"abstract":"<p><p>Marigold flowers, which are also known as <i>Tagetes erecta</i> L., are widely recognized for their bright colors and health benefits. Therefore, the purpose of this research was to investigate the quality of total carotenoid content (TCC) and quercetin in marigold flowers, specifically the edible ones, using visible near-infrared spectroscopy (Vis-NIRS) technology. Both bioactive compounds in these flowers were assessed using Vis-NIRS. The technology is considered to be a rapid and non-destructive method for evaluating the quality of agricultural products. To ensure accuracy in the evaluation, Vis-NIRS was validated against conventional methods such as spectrophotometry and chromatography. The results showed that the use of Vis-NIRS helped to accurately determine the levels of TCC and quercetin in marigold flowers. Based on the analysis results, the best accuracy values for TCC were as follows: the correlation coefficient of the calibration set (<i>R</i> <sub>cal</sub>) was 0.94, the root mean square error of the calibration set (RMSEC) was 125.57, the correlation coefficient of the prediction set (<i>R</i> <sub>pred</sub>) was 0.87, the root mean square error of the prediction set (RMSEP) was 129.35, and the ratio of prediction to deviation (RPD) was 2.77. For quercetin, the best accuracy values were: <i>R</i> <sub>cal</sub> was 0.96, RMSEC was 1.63, <i>R</i> <sub>pred</sub> was 0.88, RMSEP was 2.37, and RPD was 2.09. These results demonstrate that the method provides a reliable alternative to destructive method. The research showed that Vis-NIRS served as a reliable quality assurance tool for assessing bioactive compounds in marigold flowers.</p>","PeriodicalId":14125,"journal":{"name":"International Journal of Food Science","volume":"2025 ","pages":"3277288"},"PeriodicalIF":2.7000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11753848/pdf/","citationCount":"0","resultStr":"{\"title\":\"Quality Assurance of Total Carotenoids and Quercetin in Marigold Flowers (<i>Tagetes erecta</i> L.) as Edible Flowers.\",\"authors\":\"Kusumiyati Kusumiyati, Ine Elisa Putri, Yuda Hadiwijaya, Agitha Kartika, Yusuf Eka Maulana, Wawan Sutari\",\"doi\":\"10.1155/ijfo/3277288\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Marigold flowers, which are also known as <i>Tagetes erecta</i> L., are widely recognized for their bright colors and health benefits. Therefore, the purpose of this research was to investigate the quality of total carotenoid content (TCC) and quercetin in marigold flowers, specifically the edible ones, using visible near-infrared spectroscopy (Vis-NIRS) technology. Both bioactive compounds in these flowers were assessed using Vis-NIRS. The technology is considered to be a rapid and non-destructive method for evaluating the quality of agricultural products. To ensure accuracy in the evaluation, Vis-NIRS was validated against conventional methods such as spectrophotometry and chromatography. The results showed that the use of Vis-NIRS helped to accurately determine the levels of TCC and quercetin in marigold flowers. Based on the analysis results, the best accuracy values for TCC were as follows: the correlation coefficient of the calibration set (<i>R</i> <sub>cal</sub>) was 0.94, the root mean square error of the calibration set (RMSEC) was 125.57, the correlation coefficient of the prediction set (<i>R</i> <sub>pred</sub>) was 0.87, the root mean square error of the prediction set (RMSEP) was 129.35, and the ratio of prediction to deviation (RPD) was 2.77. For quercetin, the best accuracy values were: <i>R</i> <sub>cal</sub> was 0.96, RMSEC was 1.63, <i>R</i> <sub>pred</sub> was 0.88, RMSEP was 2.37, and RPD was 2.09. These results demonstrate that the method provides a reliable alternative to destructive method. The research showed that Vis-NIRS served as a reliable quality assurance tool for assessing bioactive compounds in marigold flowers.</p>\",\"PeriodicalId\":14125,\"journal\":{\"name\":\"International Journal of Food Science\",\"volume\":\"2025 \",\"pages\":\"3277288\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2025-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11753848/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Food Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/ijfo/3277288\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Food Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/ijfo/3277288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
万寿菊,也被称为万寿菊,因其鲜艳的颜色和对健康的益处而被广泛认可。因此,本研究旨在利用可见近红外光谱(Vis-NIRS)技术对万寿菊中总类胡萝卜素(TCC)和槲皮素(quercetin)的质量进行研究。用可见光-近红外光谱对这些花中的两种生物活性化合物进行了评估。该技术被认为是一种快速、无损的农产品质量评价方法。为了确保评估的准确性,Vis-NIRS与常规方法(如分光光度法和色谱法)进行了验证。结果表明,采用可见光近红外光谱法可以准确测定万寿菊中TCC和槲皮素的含量。分析结果表明,TCC的最佳准确度值为:校正集相关系数(R cal)为0.94,校正集均方根误差(RMSEC)为125.57,预测集相关系数(R pred)为0.87,预测集均方根误差(RMSEP)为129.35,预测偏差比(RPD)为2.77。槲皮素的最佳准确度为:R cal = 0.96, RMSEC = 1.63, R pred = 0.88, RMSEP = 2.37, RPD = 2.09。这些结果表明,该方法是一种可靠的替代破坏性方法。研究表明,可见近红外光谱是万寿菊花中生物活性成分鉴定的可靠质量保证工具。
Quality Assurance of Total Carotenoids and Quercetin in Marigold Flowers (Tagetes erecta L.) as Edible Flowers.
Marigold flowers, which are also known as Tagetes erecta L., are widely recognized for their bright colors and health benefits. Therefore, the purpose of this research was to investigate the quality of total carotenoid content (TCC) and quercetin in marigold flowers, specifically the edible ones, using visible near-infrared spectroscopy (Vis-NIRS) technology. Both bioactive compounds in these flowers were assessed using Vis-NIRS. The technology is considered to be a rapid and non-destructive method for evaluating the quality of agricultural products. To ensure accuracy in the evaluation, Vis-NIRS was validated against conventional methods such as spectrophotometry and chromatography. The results showed that the use of Vis-NIRS helped to accurately determine the levels of TCC and quercetin in marigold flowers. Based on the analysis results, the best accuracy values for TCC were as follows: the correlation coefficient of the calibration set (Rcal) was 0.94, the root mean square error of the calibration set (RMSEC) was 125.57, the correlation coefficient of the prediction set (Rpred) was 0.87, the root mean square error of the prediction set (RMSEP) was 129.35, and the ratio of prediction to deviation (RPD) was 2.77. For quercetin, the best accuracy values were: Rcal was 0.96, RMSEC was 1.63, Rpred was 0.88, RMSEP was 2.37, and RPD was 2.09. These results demonstrate that the method provides a reliable alternative to destructive method. The research showed that Vis-NIRS served as a reliable quality assurance tool for assessing bioactive compounds in marigold flowers.
期刊介绍:
International Journal of Food Science is a peer-reviewed, Open Access journal that publishes research and review articles in all areas of food science. As a multidisciplinary journal, articles discussing all aspects of food science will be considered, including, but not limited to: enhancing shelf life, food deterioration, food engineering, food handling, food processing, food quality, food safety, microbiology, and nutritional research. The journal aims to provide a valuable resource for food scientists, food producers, food retailers, nutritionists, the public health sector, and relevant governmental and non-governmental agencies.