斑点跟踪超声心动图近场杂波抑制。

IF 2.4 3区 医学 Q2 ACOUSTICS
Yue Xu , Kai-Hang Yiu , Wei-Ning Lee
{"title":"斑点跟踪超声心动图近场杂波抑制。","authors":"Yue Xu ,&nbsp;Kai-Hang Yiu ,&nbsp;Wei-Ning Lee","doi":"10.1016/j.ultrasmedbio.2024.12.016","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.</div></div><div><h3>Methods</h3><div><em>In silico</em>, material points and their displacements in a homogeneous medium under uniaxial compressions (0.5% - 9% axial strains at 0.5% increments) were simulated in finite-element models. They were exported to the k-Wave toolbox for simulations of pre- and post-deformed ultrasound images with/ without a realistic phase aberrating layer in a high-contrast diverging wave compounding scheme. <em>In vivo</em>, echocardiograms of 20 normal human hearts were acquired using a coded diverging wave compounding imaging method at 3200 frames/second in the transthoracic apical four-chamber view. Morphological component analysis (MCA), which is also a sparse representation method but computationally intensive, was used for comparison with rSVD. Both rSVD- and MCA-based filters were applied to beamformed ultrasound radio-frequency (RF) data before cross-correlation-based speckle tracking. Contrast-to-noise ratios (CNRs) and root-mean-square deviations (RMSDs) were computed from regions of interest to evaluate NF clutter filtering performance of rSVD and MCA.</div></div><div><h3>Results</h3><div><em>In silico</em>, 2-D displacements estimated from rSVD-based clutter-reduced image data showed strong agreement with ground truth (R<sup>2</sup> of 0.95). <em>In vivo</em>, CNR improvements ranged from 1.02 dB to 17.68 dB, consistently enhancing image quality across all subjects. An improvement of ∼4.9 dB in the apical segments was observed in 80% of cases. Mean RMSDs were below 5.0% for all rSVD-based NF clutter-reduced data. While both rSVD and MCA effectively filtered NF clutter, rSVD was significantly more practical.</div></div><div><h3>Conclusion</h3><div>Our findings confirm the reliability, accuracy, and efficiency of rSVD-based clutter filtering in speckle tracking echocardiography. This underscores the feasibility of matrix decomposition-based methods, exemplified by rSVD, in NF clutter filtering for myocardial motion estimation.</div></div>","PeriodicalId":49399,"journal":{"name":"Ultrasound in Medicine and Biology","volume":"51 4","pages":"Pages 683-694"},"PeriodicalIF":2.4000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Near-Field Clutter Mitigation in Speckle Tracking Echocardiography\",\"authors\":\"Yue Xu ,&nbsp;Kai-Hang Yiu ,&nbsp;Wei-Ning Lee\",\"doi\":\"10.1016/j.ultrasmedbio.2024.12.016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.</div></div><div><h3>Methods</h3><div><em>In silico</em>, material points and their displacements in a homogeneous medium under uniaxial compressions (0.5% - 9% axial strains at 0.5% increments) were simulated in finite-element models. They were exported to the k-Wave toolbox for simulations of pre- and post-deformed ultrasound images with/ without a realistic phase aberrating layer in a high-contrast diverging wave compounding scheme. <em>In vivo</em>, echocardiograms of 20 normal human hearts were acquired using a coded diverging wave compounding imaging method at 3200 frames/second in the transthoracic apical four-chamber view. Morphological component analysis (MCA), which is also a sparse representation method but computationally intensive, was used for comparison with rSVD. Both rSVD- and MCA-based filters were applied to beamformed ultrasound radio-frequency (RF) data before cross-correlation-based speckle tracking. Contrast-to-noise ratios (CNRs) and root-mean-square deviations (RMSDs) were computed from regions of interest to evaluate NF clutter filtering performance of rSVD and MCA.</div></div><div><h3>Results</h3><div><em>In silico</em>, 2-D displacements estimated from rSVD-based clutter-reduced image data showed strong agreement with ground truth (R<sup>2</sup> of 0.95). <em>In vivo</em>, CNR improvements ranged from 1.02 dB to 17.68 dB, consistently enhancing image quality across all subjects. An improvement of ∼4.9 dB in the apical segments was observed in 80% of cases. Mean RMSDs were below 5.0% for all rSVD-based NF clutter-reduced data. While both rSVD and MCA effectively filtered NF clutter, rSVD was significantly more practical.</div></div><div><h3>Conclusion</h3><div>Our findings confirm the reliability, accuracy, and efficiency of rSVD-based clutter filtering in speckle tracking echocardiography. This underscores the feasibility of matrix decomposition-based methods, exemplified by rSVD, in NF clutter filtering for myocardial motion estimation.</div></div>\",\"PeriodicalId\":49399,\"journal\":{\"name\":\"Ultrasound in Medicine and Biology\",\"volume\":\"51 4\",\"pages\":\"Pages 683-694\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound in Medicine and Biology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0301562924004757\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound in Medicine and Biology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0301562924004757","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:近场杂波滤波是揭示真实心肌结构和动态的关键。随机奇异值分解(rSVD)以其计算效率和鲁棒性突出。研究了基于rsvd的NF杂波滤波对心肌运动估计的影响。方法:在硅材料中,在单轴压缩(0.5% - 9%轴向应变,0.5%增量)的均匀介质中,材料点及其位移在有限元模型中进行了模拟。它们被导出到k-Wave工具箱中,用于在高对比度发散波复合方案中模拟具有/不具有真实相位像差层的变形前和变形后超声图像。在体内,采用编码发散波复合成像方法,以3200帧/秒的速度获得了20颗正常人类心脏的超声心动图。形态学成分分析(MCA)也是一种稀疏表示方法,但计算量大,与rSVD进行比较。在基于互相关的散斑跟踪之前,将基于rSVD和mca的滤波器应用于波束形成超声射频(RF)数据。从感兴趣的区域计算噪声对比比(CNRs)和均方根偏差(rmsd),以评估rSVD和MCA的NF杂波滤波性能。结果:在计算机上,基于rsvd的杂波减少图像数据估计的二维位移与地面真实值非常吻合(R2为0.95)。在体内,CNR的改善幅度从1.02 dB到17.68 dB不等,所有受试者的图像质量都得到了持续提高。在80%的病例中,观察到根尖段改善约4.9 dB。对于所有基于rsvd的NF杂波减少数据,平均rmsd低于5.0%。虽然rSVD和MCA都能有效地过滤NF杂波,但rSVD明显更实用。结论:我们的研究结果证实了基于rsvd的杂波滤波在斑点跟踪超声心动图中的可靠性、准确性和有效性。这强调了基于矩阵分解的方法的可行性,以rSVD为例,在心肌运动估计的NF杂波滤波中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Near-Field Clutter Mitigation in Speckle Tracking Echocardiography

Objective

Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.

Methods

In silico, material points and their displacements in a homogeneous medium under uniaxial compressions (0.5% - 9% axial strains at 0.5% increments) were simulated in finite-element models. They were exported to the k-Wave toolbox for simulations of pre- and post-deformed ultrasound images with/ without a realistic phase aberrating layer in a high-contrast diverging wave compounding scheme. In vivo, echocardiograms of 20 normal human hearts were acquired using a coded diverging wave compounding imaging method at 3200 frames/second in the transthoracic apical four-chamber view. Morphological component analysis (MCA), which is also a sparse representation method but computationally intensive, was used for comparison with rSVD. Both rSVD- and MCA-based filters were applied to beamformed ultrasound radio-frequency (RF) data before cross-correlation-based speckle tracking. Contrast-to-noise ratios (CNRs) and root-mean-square deviations (RMSDs) were computed from regions of interest to evaluate NF clutter filtering performance of rSVD and MCA.

Results

In silico, 2-D displacements estimated from rSVD-based clutter-reduced image data showed strong agreement with ground truth (R2 of 0.95). In vivo, CNR improvements ranged from 1.02 dB to 17.68 dB, consistently enhancing image quality across all subjects. An improvement of ∼4.9 dB in the apical segments was observed in 80% of cases. Mean RMSDs were below 5.0% for all rSVD-based NF clutter-reduced data. While both rSVD and MCA effectively filtered NF clutter, rSVD was significantly more practical.

Conclusion

Our findings confirm the reliability, accuracy, and efficiency of rSVD-based clutter filtering in speckle tracking echocardiography. This underscores the feasibility of matrix decomposition-based methods, exemplified by rSVD, in NF clutter filtering for myocardial motion estimation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.20
自引率
6.90%
发文量
325
审稿时长
70 days
期刊介绍: Ultrasound in Medicine and Biology is the official journal of the World Federation for Ultrasound in Medicine and Biology. The journal publishes original contributions that demonstrate a novel application of an existing ultrasound technology in clinical diagnostic, interventional and therapeutic applications, new and improved clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and the interactions between ultrasound and biological systems, including bioeffects. Papers that simply utilize standard diagnostic ultrasound as a measuring tool will be considered out of scope. Extended critical reviews of subjects of contemporary interest in the field are also published, in addition to occasional editorial articles, clinical and technical notes, book reviews, letters to the editor and a calendar of forthcoming meetings. It is the aim of the journal fully to meet the information and publication requirements of the clinicians, scientists, engineers and other professionals who constitute the biomedical ultrasonic community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信