比较:进口与国产第四代HIV免疫诊断试剂盒。

IF 0.6 Q4 HEMATOLOGY
Asian Journal of Transfusion Science Pub Date : 2024-07-01 Epub Date: 2024-12-21 DOI:10.4103/ajts.ajts_224_23
Rajesh Kumar Sharma, Bharti Chauhan, Ashrat Manzoor, Rajeev Kumar, Daud Ali, Rich Baranwal, Akanksha Bisht, Harish Chander, Anup Anvikar
{"title":"比较:进口与国产第四代HIV免疫诊断试剂盒。","authors":"Rajesh Kumar Sharma, Bharti Chauhan, Ashrat Manzoor, Rajeev Kumar, Daud Ali, Rich Baranwal, Akanksha Bisht, Harish Chander, Anup Anvikar","doi":"10.4103/ajts.ajts_224_23","DOIUrl":null,"url":null,"abstract":"<p><p>Early detection of any disease is always a life-saving methodology for human beings likewise the detection of p24 antigen is always better than the detection of HIV antibodies. In the current era, p24 antigen is added additionally in HIV antibodies detection assays and called HIV fourth-generation immunodiagnostic kit. The different HIV fourth-generation kit having different capacities to pick up the low concentration of analyte as well as represent the detection values in different units. A total of 30 assays were used in this study and it was found that the detection concentration assigned by the manufacturers in the case of imported kits was 0.48 IU/mL to 2 IU/mL. However, the detection range of the indigenous kits was 25 pg/mL to 1000 IU/mL. This study gives an idea/knowledge for the startups concerned with high hope and broad scope for make in India concept in the IVDs market.</p>","PeriodicalId":42296,"journal":{"name":"Asian Journal of Transfusion Science","volume":"18 2","pages":"359-362"},"PeriodicalIF":0.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11734770/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits.\",\"authors\":\"Rajesh Kumar Sharma, Bharti Chauhan, Ashrat Manzoor, Rajeev Kumar, Daud Ali, Rich Baranwal, Akanksha Bisht, Harish Chander, Anup Anvikar\",\"doi\":\"10.4103/ajts.ajts_224_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Early detection of any disease is always a life-saving methodology for human beings likewise the detection of p24 antigen is always better than the detection of HIV antibodies. In the current era, p24 antigen is added additionally in HIV antibodies detection assays and called HIV fourth-generation immunodiagnostic kit. The different HIV fourth-generation kit having different capacities to pick up the low concentration of analyte as well as represent the detection values in different units. A total of 30 assays were used in this study and it was found that the detection concentration assigned by the manufacturers in the case of imported kits was 0.48 IU/mL to 2 IU/mL. However, the detection range of the indigenous kits was 25 pg/mL to 1000 IU/mL. This study gives an idea/knowledge for the startups concerned with high hope and broad scope for make in India concept in the IVDs market.</p>\",\"PeriodicalId\":42296,\"journal\":{\"name\":\"Asian Journal of Transfusion Science\",\"volume\":\"18 2\",\"pages\":\"359-362\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11734770/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Transfusion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ajts.ajts_224_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Transfusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ajts.ajts_224_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

任何疾病的早期检测都是拯救人类生命的方法,同样,p24抗原的检测总是比HIV抗体的检测更好。在当今时代,p24抗原被额外添加到HIV抗体检测中,被称为HIV第四代免疫诊断试剂盒。不同的HIV第四代试剂盒对低浓度分析物的检测能力不同,并代表不同单位的检测值。本研究共使用了30种检测方法,发现进口试剂盒中制造商指定的检测浓度为0.48 IU/mL至2 IU/mL。而本土试剂盒的检测范围为25 pg/mL ~ 1000 IU/mL。这项研究为初创公司提供了一个想法/知识,这些初创公司对ivd市场上的印度制造概念抱有很高的希望和广阔的空间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits.

Early detection of any disease is always a life-saving methodology for human beings likewise the detection of p24 antigen is always better than the detection of HIV antibodies. In the current era, p24 antigen is added additionally in HIV antibodies detection assays and called HIV fourth-generation immunodiagnostic kit. The different HIV fourth-generation kit having different capacities to pick up the low concentration of analyte as well as represent the detection values in different units. A total of 30 assays were used in this study and it was found that the detection concentration assigned by the manufacturers in the case of imported kits was 0.48 IU/mL to 2 IU/mL. However, the detection range of the indigenous kits was 25 pg/mL to 1000 IU/mL. This study gives an idea/knowledge for the startups concerned with high hope and broad scope for make in India concept in the IVDs market.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
56
审稿时长
44 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信