人工与无标记(图像引导系统)环形人工晶状体植入术治疗白内障手术散光的效果。

Q4 Medicine
Acta Medica Philippina Pub Date : 2024-12-18 eCollection Date: 2024-01-01 DOI:10.47895/amp.vi0.8029
Nilo Vincent Dg FlorCruz, Richard C Kho, Aramis B Torrefranca
{"title":"人工与无标记(图像引导系统)环形人工晶状体植入术治疗白内障手术散光的效果。","authors":"Nilo Vincent Dg FlorCruz, Richard C Kho, Aramis B Torrefranca","doi":"10.47895/amp.vi0.8029","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Toric intraocular lens implantation has been used to correct corneal astigmatism during cataract surgery. The study aimed to compare the visual outcomes between manual vs markerless toric intraocular lens implantation in astigmatic correction.</p><p><strong>Methods: </strong>The medical records of patients at American Eye Center who underwent phacoemulsification by multiple surgeons with insertion of monofocal or multifocal toric lenses via manual marking and markerless method from 2010-2019 were reviewed.</p><p><strong>Results: </strong>A total of 70 patients were included in the study. Results showed no significant difference in the following characteristics between manual and markerless method at one month and two months post-cataract surgery: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near vision acuity (UNVA), corrected near vision acuity (CNVA), refraction spherical equivalent. The UDVA, CDVA, UNVA, CNVA and astigmatism had significantly lower median/mean-rank at one and two months postoperatively compared to pre-operative values.</p><p><strong>Conclusion: </strong>In conclusion, our findings indicated that both manual-based and markerless systems effectively facilitated accurate placement of the toric IOL on the desired axis. Notably, there was no significant difference observed between the two methods. Both systems are straightforward to execute. In low-resource settings like the Philippines, the manual marking method can be employed when markerless guidance equipment is unavailable.</p>","PeriodicalId":6994,"journal":{"name":"Acta Medica Philippina","volume":"58 23","pages":"83-88"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11739523/pdf/","citationCount":"0","resultStr":"{\"title\":\"Manual versus Markerless (Image-guided System) Toric Intraocular Lens Implantation Outcomes for Astigmatic Correction in Cataract Surgeries.\",\"authors\":\"Nilo Vincent Dg FlorCruz, Richard C Kho, Aramis B Torrefranca\",\"doi\":\"10.47895/amp.vi0.8029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Toric intraocular lens implantation has been used to correct corneal astigmatism during cataract surgery. The study aimed to compare the visual outcomes between manual vs markerless toric intraocular lens implantation in astigmatic correction.</p><p><strong>Methods: </strong>The medical records of patients at American Eye Center who underwent phacoemulsification by multiple surgeons with insertion of monofocal or multifocal toric lenses via manual marking and markerless method from 2010-2019 were reviewed.</p><p><strong>Results: </strong>A total of 70 patients were included in the study. Results showed no significant difference in the following characteristics between manual and markerless method at one month and two months post-cataract surgery: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near vision acuity (UNVA), corrected near vision acuity (CNVA), refraction spherical equivalent. The UDVA, CDVA, UNVA, CNVA and astigmatism had significantly lower median/mean-rank at one and two months postoperatively compared to pre-operative values.</p><p><strong>Conclusion: </strong>In conclusion, our findings indicated that both manual-based and markerless systems effectively facilitated accurate placement of the toric IOL on the desired axis. Notably, there was no significant difference observed between the two methods. Both systems are straightforward to execute. In low-resource settings like the Philippines, the manual marking method can be employed when markerless guidance equipment is unavailable.</p>\",\"PeriodicalId\":6994,\"journal\":{\"name\":\"Acta Medica Philippina\",\"volume\":\"58 23\",\"pages\":\"83-88\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11739523/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Medica Philippina\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47895/amp.vi0.8029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Medica Philippina","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47895/amp.vi0.8029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:应用环形人工晶状体植入术矫正白内障手术中角膜散光。本研究旨在比较人工人工晶状体植入术与无标记人工晶状体植入术在散光矫正中的视力效果。方法:回顾2010-2019年美国眼科中心多名外科医生采用人工标记和无标记方法置入单焦点或多焦点晶状体的超声乳化手术患者的病历。结果:共纳入70例患者。结果:白内障术后1个月和2个月,手工和无标记方法的以下指标:未矫正距离视力(UDVA)、矫正距离视力(CDVA)、未矫正近视力(UNVA)、矫正近视力(CNVA)、屈光球等效。与术前相比,UDVA、CDVA、UNVA、CNVA和散光在术后1个月和2个月的中位/平均排名显著降低。结论:总之,我们的研究结果表明,基于手动和无标记系统有效地促进了环形人工晶体在所需轴上的准确放置。值得注意的是,两种方法之间没有显著差异。这两个系统都很容易执行。在像菲律宾这样的低资源环境中,当无标记导航设备不可用时,可以采用手动标记方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Manual versus Markerless (Image-guided System) Toric Intraocular Lens Implantation Outcomes for Astigmatic Correction in Cataract Surgeries.

Objective: Toric intraocular lens implantation has been used to correct corneal astigmatism during cataract surgery. The study aimed to compare the visual outcomes between manual vs markerless toric intraocular lens implantation in astigmatic correction.

Methods: The medical records of patients at American Eye Center who underwent phacoemulsification by multiple surgeons with insertion of monofocal or multifocal toric lenses via manual marking and markerless method from 2010-2019 were reviewed.

Results: A total of 70 patients were included in the study. Results showed no significant difference in the following characteristics between manual and markerless method at one month and two months post-cataract surgery: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near vision acuity (UNVA), corrected near vision acuity (CNVA), refraction spherical equivalent. The UDVA, CDVA, UNVA, CNVA and astigmatism had significantly lower median/mean-rank at one and two months postoperatively compared to pre-operative values.

Conclusion: In conclusion, our findings indicated that both manual-based and markerless systems effectively facilitated accurate placement of the toric IOL on the desired axis. Notably, there was no significant difference observed between the two methods. Both systems are straightforward to execute. In low-resource settings like the Philippines, the manual marking method can be employed when markerless guidance equipment is unavailable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Medica Philippina
Acta Medica Philippina Medicine-Medicine (all)
CiteScore
0.40
自引率
0.00%
发文量
199
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信